Actions

Difference between revisions of "Atmospheric Components Quick Reference"

From Unofficial Stationeers Wiki

(Add Air Conditioner and Wall Cooler.)
m (Changed Wattage of Pipe Analyzer)
 
(14 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 
This is a quick reference to the various components of a piped-fluid network.
 
This is a quick reference to the various components of a piped-fluid network.
  
{| class="wikitable"
+
{| class="wikitable sortable"
 
|-
 
|-
! Component !! Kit !! Inputs !! Outputs !! One-way? !! Switched? !! Compressor? !! Max. Power !! Primary Function
+
! Component !! Kit !! Inputs !! Outputs !! One-way? !! Switched? !! Compressor? !! Volume !! Max. Pressure !! Max. Power !! Primary Function
 
|-
 
|-
| [[Pipes|Pipe]] (various shapes) || [[Pipes]] || colspan="2"|2-6 generic || No || No || No || - || Provide a pathway.
+
| [[Pipes|Pipe]] (various shapes) || [[Pipes|Kit (Pipe)]], also craftable at [[Autolathe]] || colspan="2"|2-6 generic || No || No || No || 100 L || 60 MPa || - || Provide a pathway.
 
|-
 
|-
| [[Pipe Valve]] || [[Pipe Valve]] || colspan="2"|2 generic || No || Manual || No|| -|| Open/close flow manually.
+
| [[Pipe Label]] || [[Pipe Label|Kit (Pipe Label)]] || colspan="2"|clamp-on || - || - || - || - || - || - || Visually label pipes.
 
|-
 
|-
| [[Pipe Digital Valve]] || [[Pipe Digital Valve]] || colspan="2"|2 generic || No || Yes || No || 25W || Open/close flow using [[Kit (Logic I/O)|logic circuits]].
+
| [[Pipe Valve]] || [[Pipe Valve|Kit (Pipe Valve)]] || colspan="2"|2 generic || No || Manual only || No|| ? || ? || - || Open/close flow manually.
 
|-
 
|-
| [[Pipe Volume Pump]] || [[Pipe Volume Pump]] || 1 || 1 || Yes || Yes || Yes || 800W, varies || Pump fluid at adjustable rate.
+
| [[Pipe Digital Valve]] || [[Pipe Digital Valve|Kit (Digital Valve)]] || colspan="2"|2 generic || No || Yes || No || ? || ? || 25W || Open/close flow using [[Kit (Logic I/O)|logic circuits]].
 
|-
 
|-
| [[Pressure_Regulator#Pressure_Regulator|Pressure Regulator]] || [[Pressure Regulator]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at output.
+
| [[Pipe Volume Pump]] || [[Pipe Volume Pump|Kit (Volume Pump)]] || 1 || 1 || Yes || Yes || Yes, adjustable || varies? || ? || 800W, varies || Pump fluid at adjustable rate.
 
|-
 
|-
| [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || [[Pressure Regulator]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at input.
+
| [[Pressure_Regulator#Pressure_Regulator|Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || ? || 20 MPa<sup>5</sup> || 100W || Achieve target pressure at output.
 
|-
 
|-
| [[Pipe Gas Mixer]] || [[Pipe Gas Mixer]] || 2 || 1 || Yes || Yes || Yes<sup>1</sup> || 100W || Combine two input mixes into one output mix, at an adjustable ratio.
+
| [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || ? || 20 MPa<sup>5</sup> || 100W || Achieve target pressure at input.
 
|-
 
|-
| [[Kit (Atmospherics) Filtration|Filtration]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || 5W || Separate an input mix into a pure output and a "leftover" output.
+
| [[Pipe Meter]] || [[Pipe Meter|Kit (Pipe Meter)]] || colspan="2"|clamp-on || - || - || - || - || - || - || Visually show pipe's pressure.
 
|-
 
|-
| [[Kit (Atmospherics) Electrolyzer|Electrolyzer]] || [[Kit (Atmospherics)]] || 1 || 1 || Yes || Yes || Yes || 1,400W || From input [[water|H<sub>2</sub>O]], output mixed [[Oxygen|O<sub>2</sub>]] and [[Volatiles]].
+
| [[Pipe Analyzer]] || [[Pipe Analyzer|Kit (Pipe Analyzer)]] || colspan="2"|clamp-on || - || - || - || - || - || 5W || Sense pipe's pressure, temperature, and composition, for visual display and logic circuits.
 
|-
 
|-
| [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || 7,000W, varies || Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs.
+
| [[Pipe Gas Mixer]] || [[Pipe Gas Mixer|Kit (Gas Mixer)]] || 2 || 1 || Yes || Yes || Yes<sup>1</sup> || ? || ? || 100W || Mix fluids: Combine two input mixes into one output mix, at an adjustable ratio.
 
|-
 
|-
| [[Wall Cooler]] || [[Wall Cooler]] || space || 1 || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || ? || Actively remove heat from a space into a pipe.
+
| [[Kit (Atmospherics) Filtration|Filtration]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || ? || ? || 5W || Sort fluids: Separate an input mix into a pure output and a "leftover" output.
 
|-
 
|-
| [[Active Vent]] || [[Active Vent]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe.
+
| [[Kit (Atmospherics) Electrolyzer|Electrolyzer]] || [[Kit (Atmospherics)]] || 1 || 1 || Yes || Yes || Yes || ? || ? || 1,400W || Create fuel: From input [[water|H<sub>2</sub>O]], output mixed [[Oxygen|O<sub>2</sub>]] and [[Volatiles]].
 
|-
 
|-
| [[Passive Vent]] || [[Passive Vent]] || colspan="2"|1 pipe, 1 space || No || No || No || - || Equalize pressure between a space and a pipe.
+
| [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || ? || ? || 7,000W, varies || Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs.
 
|-
 
|-
| [[Gas Tank Storage]] || kit || x || x || 1w || switch || comp || 100W || function
+
| [[Wall Cooler]] || [[Wall Cooler|Kit (Wall Cooler)]] || 1 space || 1 || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || ? || ? || ? || Cool a space: Actively remove heat from a space into a pipe.
 
|-
 
|-
| [[Tank]] (Large and Small) || kit || x || x || 1w || switch || comp || 100W || function
+
| [[Wall Heater]] || [[Wall Heater|Kit (Wall Heater)]] || colspan="2"|1 space || - || - || - || - || - || 1010W || Heat a space: Convert electric power into heat.
 
|-
 
|-
| [[Tank Connector]] || kit || x || x || 1w || switch || comp || 100W || function
+
| [[Pipe Radiator]] || [[Pipe Radiator|Kit (Pipe Radiator)]] || colspan="2"|clamp-on || - || - || - || - || - || - || Heat/cool: Passively exchange heat between a pipe and a space.
 +
|-
 +
| [[Active Vent]] || [[Active Vent|Kit (Active Vent)]] || colspan="2"|1 generic, 1 space || Yes, reversable || Yes || Yes || ? || ?<sup>3</sup> || 100W || Pump pressure between a space and a pipe.
 +
|-
 +
| [[Passive Vent]] || [[Passive Vent|Kit (Passive Vent)]] || colspan="2"|1 generic, 1 space || No || No || No || - || - || - || Equalize pressure between a space and a pipe.
 +
|-
 +
| [[Gas Tank Storage]] || [[Gas Tank Storage|Kit (Canister Storage)]] || colspan="2"|1 generic || No || No || No || 64 L<sup>4</sup> || 101 MPa<sup>4</sup> || - || Small storage: Attach pipes to [[Gas Canister]]s (removable, inventory-portable fluid storage).
 +
|-
 +
| [[Tank Connector]] || [[Tank Connector|Kit (Tank Connector)]] || colspan="2"|1 generic || No || No || No || 790 L<sup>4</sup> || 10.1 MPa<sup>4</sup> || - || Medium storage: Attach pipes to [[Portable Tank]]s (removable, draggable fluid storage), and also to [[Portable Air Scrubber]]s and [[Portable Air Conditioner]]s.
 +
|-
 +
| [[Tank|Small Tank]] || [[Tank|Kit (Tank)]] || colspan="2"|1 generic || No || Logic only? || No || 6 kL || 60 MPa || - || Permanent, high-capacity fluid storage.
 +
|-
 +
| [[Tank|Large Tank]] || [[Tank|Kit (Tank)]] × 5 || colspan="2"|1 generic || No || Logic only? || No || 50 kL || 60 MPa || - || Permanent, super-capacity fluid storage.
 +
|-
 +
| [[Furnace]] || [[Furnace|Kit (Furnace)]], craftable at [[Autolathe]] || 1 || 1 || Yes || No || No || 1 kL || ? || - || Smelt ores, but can also melt/sublimate Ices directly into a pipe.
 +
|-
 +
| [[Advanced Furnace]] || [[Advanced Furnace|Kit (Advanced Furnace)]], craftable at [[Electronics Printer]] Mk. II || 1 || 1 || Yes || Yes || Yes, adjustable || 1 kL? || ? || ? || Smelt ores and sublimate Ices, with active, adjustable pumping on input and output.
 
|}
 
|}
  
'''Kit''': The item used to build the component. All of these items are manufactured with a [[Hydraulic Pipe Bender]] or [[Fabricator]], except where noted.
+
'''Kit:''' The item used to build the component. These are the names as they appear in fabrication lists, which does not always match the true name of the item. Except where noted, all of these items are manufactured with a [[Hydraulic Pipe Bender]].
 +
 
 +
'''Input/Output:''' "Generic" connections are pipe fittings that are not explicitly for input or output. "Space" indicates an interface to fluids that are not contained in pipes (e.g., the atmosphere or the contents of a room). "Clamp-on" components have no fittings of their own; they clamp onto an existing Straight Pipe.
 +
 
 +
'''One-way:''' Does the component prevent fluid from flowing the wrong way, from output to input?
  
'''One-way''': Does the component prevent fluid from flowing the wrong way, from output to input?
+
'''Switched:''' Does it prevent all flow when switched off or unpowered? Except where noted, switched components can be switched either manually or using [[Kit (Logic I/O)|logic circuits]].
  
'''Switched''': Does it prevent all flow when switched off or unpowered? All switched components can be switched either manually or using [[Kit (Logic I/O)|logic circuits]].
+
'''Compressor:''' Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output, or it does not enable any pressure changes.
  
'''Compressor''': Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output.
+
'''Max. Pressure:''' The component will begin to fail when pressure exceeds this. More precisely, this is the maximum ''difference'' in pressure between the component's internal volume and the surrounding space. Some components list "60 MPa" because attached pipes will fail, even if the true limit of the component itself is unknown. Even where a higher limit is known (e.g., canisters), this limitation still holds and places a practical maximum on most setups.
  
 
'''Note 1:''' While the Pipe Gas Mixer will actively compress from output to input, it will stop when either input is empty, to preserve the mix ratio.
 
'''Note 1:''' While the Pipe Gas Mixer will actively compress from output to input, it will stop when either input is empty, to preserve the mix ratio.
  
 
'''Note 2:''' The Wall Cooler's one-way, switched, and "compressor" qualities apply only to the heat exchange. It does not directly affect the pressure or flow in its attached pipe.
 
'''Note 2:''' The Wall Cooler's one-way, switched, and "compressor" qualities apply only to the heat exchange. It does not directly affect the pressure or flow in its attached pipe.
 +
 +
'''Note 3:''' The Active Vent will ''fail'' at ? MPa. The pressure at which it will stop pumping is configurable through the data network and defaults to 0 Pa for Inward mode and 101 kPa (1 standard atmosphere) for Outward mode.
 +
 +
'''Note 4:''' These Volume and Max. Pressure ratings reflect the limits of the removable canisters and tanks. Note that the 101 MPa limit of a Gas Canister is considerably higher than the 60 MPa overall limit of a pipe network.
 +
 +
'''Note 5:''' These Pressure limits are what max can be set on the regulators. Regulators themselves have no inner atmosphere and thus no inner pressure that would break them.

Latest revision as of 05:11, 30 January 2024

This is a quick reference to the various components of a piped-fluid network.

Component Kit Inputs Outputs One-way? Switched? Compressor? Volume Max. Pressure Max. Power Primary Function
Pipe (various shapes) Kit (Pipe), also craftable at Autolathe 2-6 generic No No No 100 L 60 MPa - Provide a pathway.
Pipe Label Kit (Pipe Label) clamp-on - - - - - - Visually label pipes.
Pipe Valve Kit (Pipe Valve) 2 generic No Manual only No  ?  ? - Open/close flow manually.
Pipe Digital Valve Kit (Digital Valve) 2 generic No Yes No  ?  ? 25W Open/close flow using logic circuits.
Pipe Volume Pump Kit (Volume Pump) 1 1 Yes Yes Yes, adjustable varies?  ? 800W, varies Pump fluid at adjustable rate.
Pressure Regulator Kit (Pressure Regulator) 1 1 Yes Yes Yes  ? 20 MPa5 100W Achieve target pressure at output.
Back Pressure Regulator Kit (Pressure Regulator) 1 1 Yes Yes Yes  ? 20 MPa5 100W Achieve target pressure at input.
Pipe Meter Kit (Pipe Meter) clamp-on - - - - - - Visually show pipe's pressure.
Pipe Analyzer Kit (Pipe Analyzer) clamp-on - - - - - 5W Sense pipe's pressure, temperature, and composition, for visual display and logic circuits.
Pipe Gas Mixer Kit (Gas Mixer) 2 1 Yes Yes Yes1  ?  ? 100W Mix fluids: Combine two input mixes into one output mix, at an adjustable ratio.
Filtration Kit (Atmospherics) 1 2 Yes Yes Yes  ?  ? 5W Sort fluids: Separate an input mix into a pure output and a "leftover" output.
Electrolyzer Kit (Atmospherics) 1 1 Yes Yes Yes  ?  ? 1,400W Create fuel: From input H2O, output mixed O2 and Volatiles.
Air Conditioner Kit (Atmospherics) 1 2 Yes Yes Yes  ?  ? 7,000W, varies Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs.
Wall Cooler Kit (Wall Cooler) 1 space 1 Yes, for heat2 Yes, for heat2 Yes, for heat2  ?  ?  ? Cool a space: Actively remove heat from a space into a pipe.
Wall Heater Kit (Wall Heater) 1 space - - - - - 1010W Heat a space: Convert electric power into heat.
Pipe Radiator Kit (Pipe Radiator) clamp-on - - - - - - Heat/cool: Passively exchange heat between a pipe and a space.
Active Vent Kit (Active Vent) 1 generic, 1 space Yes, reversable Yes Yes  ?  ?3 100W Pump pressure between a space and a pipe.
Passive Vent Kit (Passive Vent) 1 generic, 1 space No No No - - - Equalize pressure between a space and a pipe.
Gas Tank Storage Kit (Canister Storage) 1 generic No No No 64 L4 101 MPa4 - Small storage: Attach pipes to Gas Canisters (removable, inventory-portable fluid storage).
Tank Connector Kit (Tank Connector) 1 generic No No No 790 L4 10.1 MPa4 - Medium storage: Attach pipes to Portable Tanks (removable, draggable fluid storage), and also to Portable Air Scrubbers and Portable Air Conditioners.
Small Tank Kit (Tank) 1 generic No Logic only? No 6 kL 60 MPa - Permanent, high-capacity fluid storage.
Large Tank Kit (Tank) × 5 1 generic No Logic only? No 50 kL 60 MPa - Permanent, super-capacity fluid storage.
Furnace Kit (Furnace), craftable at Autolathe 1 1 Yes No No 1 kL  ? - Smelt ores, but can also melt/sublimate Ices directly into a pipe.
Advanced Furnace Kit (Advanced Furnace), craftable at Electronics Printer Mk. II 1 1 Yes Yes Yes, adjustable 1 kL?  ?  ? Smelt ores and sublimate Ices, with active, adjustable pumping on input and output.

Kit: The item used to build the component. These are the names as they appear in fabrication lists, which does not always match the true name of the item. Except where noted, all of these items are manufactured with a Hydraulic Pipe Bender.

Input/Output: "Generic" connections are pipe fittings that are not explicitly for input or output. "Space" indicates an interface to fluids that are not contained in pipes (e.g., the atmosphere or the contents of a room). "Clamp-on" components have no fittings of their own; they clamp onto an existing Straight Pipe.

One-way: Does the component prevent fluid from flowing the wrong way, from output to input?

Switched: Does it prevent all flow when switched off or unpowered? Except where noted, switched components can be switched either manually or using logic circuits.

Compressor: Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output, or it does not enable any pressure changes.

Max. Pressure: The component will begin to fail when pressure exceeds this. More precisely, this is the maximum difference in pressure between the component's internal volume and the surrounding space. Some components list "60 MPa" because attached pipes will fail, even if the true limit of the component itself is unknown. Even where a higher limit is known (e.g., canisters), this limitation still holds and places a practical maximum on most setups.

Note 1: While the Pipe Gas Mixer will actively compress from output to input, it will stop when either input is empty, to preserve the mix ratio.

Note 2: The Wall Cooler's one-way, switched, and "compressor" qualities apply only to the heat exchange. It does not directly affect the pressure or flow in its attached pipe.

Note 3: The Active Vent will fail at ? MPa. The pressure at which it will stop pumping is configurable through the data network and defaults to 0 Pa for Inward mode and 101 kPa (1 standard atmosphere) for Outward mode.

Note 4: These Volume and Max. Pressure ratings reflect the limits of the removable canisters and tanks. Note that the 101 MPa limit of a Gas Canister is considerably higher than the 60 MPa overall limit of a pipe network.

Note 5: These Pressure limits are what max can be set on the regulators. Regulators themselves have no inner atmosphere and thus no inner pressure that would break them.