Hardsuit
From Unofficial Stationeers Wiki
Max Pressure | 202.65 kPa? |
---|---|
Volume | 10 L? |
Recipe | |
Created With | Fabricator |
Cost | 2g Gold, 10g Steel, 8g Lead, 20g Invar |
Description
Used to be able to go outside a pressurized and breathable environment. It features an adjustable pressure adjustment and air conditioning toggle.
The Hardsuit has more armor than the EVA Suit and features one extra filter slot and the ability to accept IC chips
- Contains 6 slots
- 1x Air Tank - insert a Canister with 100% O2
- 1x Waste Tank - insert an empty Canister where waste gases will be stored
- 1x Life Support - insert a charged Battery Cell
- 1x Processor - insert an Integrated Circuit (IC10)
- 4x Filters - insert filters if not using 100% O2
- Note: Image is incorrect
Notes
- Note that the maximum allowed pressure for the Waste Tank is 4052kPa. Low/critical oxygen warnings will occur close to this value.
- The default filter is the CO2 filter, a gas generated by the characters when consuming breathable air.
Data Network Properties
These are all Data Network properties of this device.
The Hardsuit is uniquely capable of accepting an Integrated Ciruit (IC10). Within a hardsuit, this IC cannot toggle itself off and will run as long as there is battery power in the suit, until the IC is removed It has these unique logic variables and interactions (along with the standard variables)
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
On | Controls A/C power for suit | |
Filtration | Controls Filtration power for suit | |
AirRelease | Controls Air power for suit | |
PressureSetting | Controls target pressure for suit. Only works while helmet is closed - PressureInternal also works | |
TemperatureSetting | Controls target temperature for suit. | |
d0 | device | Interface for suit helmet |
d1 | device | Interface for backpack or jetpack |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
On | Controls A/C power for suit | |
Filtration | Controls Filtration power for suit | |
AirRelease | Controls Air power for suit | |
PressureSetting | Controls target pressure for suit. Only works while helmet is closed - PressureInternal also works | |
TemperatureSetting | Controls target temperature for suit. | |
d0 | device | Interface for suit helmet |
d1 | device | Interface for backpack or jetpack |