Difference between revisions of "Gas"
From Unofficial Stationeers Wiki
m (→Mixtures) |
(correct filter color) |
||
Line 26: | Line 26: | ||
| [[Carbon Dioxide]] (CO<sub>2</sub>) || Gray || 28.2 || 0.6kJ/MOL || 218K°/-55.3C° || N/A. || 517kPa at 218K°/-55.3C° || 265K°/-8.1C° at 6000KPa | | [[Carbon Dioxide]] (CO<sub>2</sub>) || Gray || 28.2 || 0.6kJ/MOL || 218K°/-55.3C° || N/A. || 517kPa at 218K°/-55.3C° || 265K°/-8.1C° at 6000KPa | ||
|- | |- | ||
− | | [[Nitrogen]] (N<sub>2</sub>) || | + | | [[Nitrogen]] (N<sub>2</sub>) || Black || 20.6 || 0.5kJ/MOL || 40k°/-233C° || 75K°/-198C° || 6.3kPa at 40K°/233C° || 190K°/-83C° at 6000kPa |
|- | |- | ||
| [[Nitrous Oxide]] (N<sub>2</sub>O) || Green || 37.2 || 4kJ/MOL || 252K°/-21C° || N/A || 800KPa at 252K°/-21C° || 431K/158C° at 2000kPa | | [[Nitrous Oxide]] (N<sub>2</sub>O) || Green || 37.2 || 4kJ/MOL || 252K°/-21C° || N/A || 800KPa at 252K°/-21C° || 431K/158C° at 2000kPa | ||
Line 32: | Line 32: | ||
| [[Oxygen]] (O<sub>2</sub>) || White || 21.1 || 0.8kJ/Mol || 56.4K°/-217C° || 90K°/-183C° || 6.3kPa at 56.4K/-217 C° || 162k°/-111C° at 6000kPa | | [[Oxygen]] (O<sub>2</sub>) || White || 21.1 || 0.8kJ/Mol || 56.4K°/-217C° || 90K°/-183C° || 6.3kPa at 56.4K/-217 C° || 162k°/-111C° at 6000kPa | ||
|- | |- | ||
− | | [[Pollutant]] (X) || | + | | [[Pollutant]] (X) || Yellow || 24.8 || 2 kJ/MOL || 173k°/-99.8C° || N/A || 1800kPa at 173K°/-99.8C° || 425K°/152C° at 6000kPa |
|- | |- | ||
| [[Volatiles]] (H<sub>2</sub>) || Red || 20.4 || 1kJ/MOL || 81.6K°/-192C° || 112K°/-162C° || 6.3kPa at 81.6K°/-192C° || 195K°/-78.1C° at 6000kPa | | [[Volatiles]] (H<sub>2</sub>) || Red || 20.4 || 1kJ/MOL || 81.6K°/-192C° || 112K°/-162C° || 6.3kPa at 81.6K°/-192C° || 195K°/-78.1C° at 6000kPa |
Revision as of 05:09, 31 July 2023
This is a disambiguation page, which lists pages which may be the intended target. If a page link referred you here, please consider editing it to point directly to the intended page.
- stationpedia has simple phase diagrams for all Gasses, a more complex phase change diagram can be located Here
Gas may refer to:
- Atmosphere
- Carbon Dioxide (CO2)
- Fuel (66.6% H2 + 33.3% O2)
- Hydrogen (H2)
- Nitrogen (N2)
- Nitrous Oxide (N2O)
- Oxygen (O2)
- Pollutants (X)
- Volatiles
- Water (H2O)
Gases
Name | Filter Color | Molar Heat Capacity | Latent Heat | Freezing point [K°/C°] | Boiling Point at 100KPa [K°/C°] | Minimum condensation pressure [kPa] at Temperature [K°/C°] | Max liquid temperature [K°/C°] at Pressure [kPa] |
---|---|---|---|---|---|---|---|
Carbon Dioxide (CO2) | Gray | 28.2 | 0.6kJ/MOL | 218K°/-55.3C° | N/A. | 517kPa at 218K°/-55.3C° | 265K°/-8.1C° at 6000KPa |
Nitrogen (N2) | Black | 20.6 | 0.5kJ/MOL | 40k°/-233C° | 75K°/-198C° | 6.3kPa at 40K°/233C° | 190K°/-83C° at 6000kPa |
Nitrous Oxide (N2O) | Green | 37.2 | 4kJ/MOL | 252K°/-21C° | N/A | 800KPa at 252K°/-21C° | 431K/158C° at 2000kPa |
Oxygen (O2) | White | 21.1 | 0.8kJ/Mol | 56.4K°/-217C° | 90K°/-183C° | 6.3kPa at 56.4K/-217 C° | 162k°/-111C° at 6000kPa |
Pollutant (X) | Yellow | 24.8 | 2 kJ/MOL | 173k°/-99.8C° | N/A | 1800kPa at 173K°/-99.8C° | 425K°/152C° at 6000kPa |
Volatiles (H2) | Red | 20.4 | 1kJ/MOL | 81.6K°/-192C° | 112K°/-162C° | 6.3kPa at 81.6K°/-192C° | 195K°/-78.1C° at 6000kPa |
Steam (H20) | Blue | 72 | 8kJ/MOL | 273K°/0C° | 373k°/100C° | 6.3kPa at 273K°/0C° | 643k°/370C° at 6000kPa |
* phase change has been added to the game system and most gasses now have an associated [Liquid] and a pure Solids phase .
Mixtures
Name | Contents | Tank Color | Notes |
---|---|---|---|
Fuel | 67% H2, 33%O2 | Orange | Autoignition at 573.15K°/300C° |
HydroNox | 50%H2, 50%N2O | N/A. | Autoignition at 323.15K°/50C° |
Air | 75% N2, 25% O2 | White | 16kPa Partial Pressure O2 minimum is required for human player breathing. Hyperoxia is not simulated. |
Simulation Mechanics
The simulation has been improved some of these Caviets are no longer true, update is required
- Partial ideal gas law (PV=nRT) is simulated.
- Fluid dynamics,are not simulated.
- Phase change has been added into the simulation
- Thermal radiation is not simulated, but vacuum atmosphere (not rooms) will absorb a fixed amount of energy per tick. The sun adds a fixed energy per tick.
- Each environment grid cube acts as a single point and each connected pipe network acts as a single point.
- Insulation is perfect/infinite.
- All pumps/mixer also act as a check valve.
- Gas stoichiometry is utilized. (i.e. Igniting 2H2 + O2 yields H2O instead of expected 2H2O)