Actions

Difference between revisions of "Gas"

From Unofficial Stationeers Wiki

(H2 and O2 now auto-ignite at 300C, not 50C)
(Added a combined phase change diagram.)
 
(46 intermediate revisions by 9 users not shown)
Line 3: Line 3:
 
{{Disambiguation}}
 
{{Disambiguation}}
 
Gas may refer to:
 
Gas may refer to:
 
 
* [[Atmosphere]]
 
* [[Atmosphere]]
 
* [[Special:MyLanguage/Carbon Dioxide|Carbon Dioxide (CO<sub>2</sub>)]]
 
* [[Special:MyLanguage/Carbon Dioxide|Carbon Dioxide (CO<sub>2</sub>)]]
Line 15: Line 14:
 
* [[Special:MyLanguage/Water|Water (H<sub>2</sub>O)]]
 
* [[Special:MyLanguage/Water|Water (H<sub>2</sub>O)]]
 
</translate>
 
</translate>
 +
 +
==Gases==
 +
 +
Stationpedia has simple phase diagrams for all Gases, shown in composite below. A more complex phase change diagram can be located [https://www.desmos.com/calculator/voj4scjipd Here]
 +
 +
[[File:Combined phase change diagram.png|frame|none|''A combined phase change diagram showing the phase changes of all in-game gasses.'']]
  
  
==Gases==
 
 
{| class="wikitable sortable"
 
{| class="wikitable sortable"
 
|-
 
|-
! Name !! Filter Color !! Molar Heat Capacity
+
! Name !! Filter Color !! Molar Heat Capacity<br>(J⋅K<sup>−1</sup>⋅mol<sup>−1</sup>) !! Molar Heat of Fusion<br>(kJ⋅K<sup>−1</sup>⋅mol<sup>−1</sup>) !! data-sort-type="number" | Melting Point<br>(K / °C) !! data-sort-type="number" | Boiling Point at 100 kPa<br>(K / °C) !! data-sort-type="number" | Minimum Condensation<br>(kPa at K / °C) !! data-sort-type="number" | Maximum Liquid Temperature<br>(K / °C at kPa)
 +
|-
 +
| [[Carbon Dioxide]] (CO<sub>2</sub>) || Gray || 28.2 || 0.6 || 218 / -55.3 || N/A || 517 at 218 / -55.3 || 265 / -8.1 at 6000
 
|-
 
|-
| [[Carbon Dioxide]] (CO<sub>2</sub>) || Gray || 28.2
+
| [[Nitrogen]] (N<sub>2</sub>) || Black || 20.6 || 0.5 || 40 / -233 || 75 / -198 || 6.3 at 40 / -233 || 190 / -83 at 6000
 
|-
 
|-
| [[Nitrogen]] (N<sub>2</sub>) || Green || 20.6
+
| [[Nitrous Oxide]] (N<sub>2</sub>O) || Green || 37.2 || 4 || 252 / -21 || N/A || 800 at 252 / -21 || 431 / 158 at 2000
 
|-
 
|-
| [[Nitrous Oxide]] (N<sub>2</sub>O) || Green || 23.0
+
| [[Oxygen]] (O<sub>2</sub>) || White || 21.1 || 0.8 || 56.4 / -217 || 90 / -183 || 6.3 at 56.4 / -217 || 162 / -111 at 6000
 
|-
 
|-
| [[Oxygen]] (O<sub>2</sub>) || White || 21.1
+
| [[Pollutant]] (X) || Yellow || 24.8 || 2 || 173 / -99.8 || N/A || 1800 at 173 / -99.8 || 425 / 152 at 6000
 
|-
 
|-
| [[Pollutant]] (X) || Black || 24.8
+
| [[Volatiles]] (H<sub>2</sub>) || Red || 20.4 || 1 || 81.6 / -192 || 112 / -162 || 6.3 at 81.6 / -192 || 195 / -78.1 at 6000
 
|-
 
|-
| [[Volatiles]] (H<sub>2</sub>) || Red || 20.4
+
| [[Water]] (H<sub>2</sub>0) || Blue || 72 || 8 || 273 / 0 || 373 / 100 || 6.3 at 273 / 0 || 643 / 370 at 6000
 
|}
 
|}
<sup>* Water is now a [[liquid]].</sup>
 
  
 +
Phase changes have been added to the game system and most gases now have an associated [[:Category:Liquid|Liquid]] and a pure solid phase.
 +
 +
The following exist only in solid state and have no gaseous form: Charcoal, Coal, Silicon, Iron, Copper, Nickel, Silver, Gold, Lead, Uranium.
  
 
==Mixtures==
 
==Mixtures==
Line 42: Line 50:
 
! Name !! Contents !! Tank Color !! Notes
 
! Name !! Contents !! Tank Color !! Notes
 
|-
 
|-
| [[Fuel]] || 67% H<sub>2</sub>, 33%O<sub>2</sub> || Orange || Autoignition at 300C
+
| [[Fuel]] || 67% H<sub>2</sub>, 33% O<sub>2</sub> || Orange || Autoignition at 573.15 K / 300 °C
 +
|-
 +
| [[HydroNox]] || 50% H<sub>2</sub>, 50% N<sub>2</sub>O || N/A || Autoignition at 323.15 K / 50 °C
 
|-
 
|-
| [[Air]] || 75% N<sub>2</sub>, 25% O<sub>2</sub> || White || 16kPa O<sub>2</sub> minimum is required for human player breathing. Hyperoxia is not simulated.
+
| [[Air]] || 75% N<sub>2</sub>, 25% O<sub>2</sub> || White || 16 kPa Partial Pressure O<sub>2</sub> minimum is required for human player breathing. Hyperoxia is not simulated.(NOTE: Suit air mixture should be 100% O<sub>2</sub>)
 
|}
 
|}
  
 
==Simulation Mechanics==
 
==Simulation Mechanics==
* Partial ideal gas law (PV=nRT) is simulated.
+
{| class="wikitable"
* Fluid dynamics, thermal conductivity, phase change, the rest of the ideal gas law, and others are not simulated.
+
|-
* Thermal radiation is not simulated, but vacuum atmosphere (not rooms) will absorb a fixed amount of energy per tick. The sun adds a fixed energy per tick.
+
! Concept
* Each environment grid cube acts as a single point and each connected pipe network acts as a single point.
+
! Simulated
* Insulation is perfect/infinite.
+
! Notes
* All pumps/mixer also act as a check valve.
+
|-
* Gas stoichiometry is not utilized. (i.e. Igniting 2H<sub>2</sub> + O<sub>2</sub> yields H<sub>2</sub>O instead of expected 2H<sub>2</sub>O)
+
| Ideal Gas Law (PV=nRT)  
 +
| Partial
 +
| Pressure will change with temperature, volume, and moles; Temperature will not change
 +
|-
 +
| Thermal Conductivity
 +
| No
 +
| Rate of energy transfer is the same for all substances
 +
|-
 +
| Thermal Radiation
 +
| Partial
 +
| Radiated heat is not absorbed by nearby objects
 +
|-
 +
| Phase Change
 +
| Partial
 +
| Gas/Liquid have simplified graph; Solid has a fixed temperature; Plasma is ignored
 +
|-
 +
| Fluid Dynamics
 +
| No
 +
| 'Convection' parts work in pressurized environment, other parts work in vacuum
 +
|-
 +
| Gas Stoichiometry
 +
| No
 +
| The various reactions are arbitrary and vary depending on device used for different products from the same reactants
 +
|-
 +
| Gravity/Density
 +
| No
 +
| Gas/Liquid is present in all directions
 +
|-
 +
| Environment Volume
 +
| Yes
 +
| Each environment cube acts as a single point with fixed volume
 +
|-
 +
| Pipe Volume
 +
| Yes
 +
| Each pipe network acts as a single point with fixed volume depending on number of pipes segments
 +
|-
 +
| Flow Direction
 +
| Yes
 +
| All pumps and mixer act as check valve, passive check valve available, other valves are not one-way
 +
|-
 +
| Pipe Integrity
 +
| Yes
 +
| Liquid pipes hold low pressure, but may contain both liquid and gas without consequence; Gas pipes hold high pressure, but stress and break with too much liquid
 +
|-
 +
| Heat Transfer
 +
| Partial
 +
| Liquid temperature is controlled by gas temperature (if no gas, liquid heater will not function)
 +
|}
 +
 
 +
[[Category:Gas]][[Category:Liquid]]

Latest revision as of 21:30, 13 April 2024

This is a disambiguation page, which lists pages which may be the intended target. If a page link referred you here, please consider editing it to point directly to the intended page.

Gas may refer to:

Gases[edit]

Stationpedia has simple phase diagrams for all Gases, shown in composite below. A more complex phase change diagram can be located Here

A combined phase change diagram showing the phase changes of all in-game gasses.


Name Filter Color Molar Heat Capacity
(J⋅K−1⋅mol−1)
Molar Heat of Fusion
(kJ⋅K−1⋅mol−1)
Melting Point
(K / °C)
Boiling Point at 100 kPa
(K / °C)
Minimum Condensation
(kPa at K / °C)
Maximum Liquid Temperature
(K / °C at kPa)
Carbon Dioxide (CO2) Gray 28.2 0.6 218 / -55.3 N/A 517 at 218 / -55.3 265 / -8.1 at 6000
Nitrogen (N2) Black 20.6 0.5 40 / -233 75 / -198 6.3 at 40 / -233 190 / -83 at 6000
Nitrous Oxide (N2O) Green 37.2 4 252 / -21 N/A 800 at 252 / -21 431 / 158 at 2000
Oxygen (O2) White 21.1 0.8 56.4 / -217 90 / -183 6.3 at 56.4 / -217 162 / -111 at 6000
Pollutant (X) Yellow 24.8 2 173 / -99.8 N/A 1800 at 173 / -99.8 425 / 152 at 6000
Volatiles (H2) Red 20.4 1 81.6 / -192 112 / -162 6.3 at 81.6 / -192 195 / -78.1 at 6000
Water (H20) Blue 72 8 273 / 0 373 / 100 6.3 at 273 / 0 643 / 370 at 6000

Phase changes have been added to the game system and most gases now have an associated Liquid and a pure solid phase.

The following exist only in solid state and have no gaseous form: Charcoal, Coal, Silicon, Iron, Copper, Nickel, Silver, Gold, Lead, Uranium.

Mixtures[edit]

Name Contents Tank Color Notes
Fuel 67% H2, 33% O2 Orange Autoignition at 573.15 K / 300 °C
HydroNox 50% H2, 50% N2O N/A Autoignition at 323.15 K / 50 °C
Air 75% N2, 25% O2 White 16 kPa Partial Pressure O2 minimum is required for human player breathing. Hyperoxia is not simulated.(NOTE: Suit air mixture should be 100% O2)

Simulation Mechanics[edit]

Concept Simulated Notes
Ideal Gas Law (PV=nRT) Partial Pressure will change with temperature, volume, and moles; Temperature will not change
Thermal Conductivity No Rate of energy transfer is the same for all substances
Thermal Radiation Partial Radiated heat is not absorbed by nearby objects
Phase Change Partial Gas/Liquid have simplified graph; Solid has a fixed temperature; Plasma is ignored
Fluid Dynamics No 'Convection' parts work in pressurized environment, other parts work in vacuum
Gas Stoichiometry No The various reactions are arbitrary and vary depending on device used for different products from the same reactants
Gravity/Density No Gas/Liquid is present in all directions
Environment Volume Yes Each environment cube acts as a single point with fixed volume
Pipe Volume Yes Each pipe network acts as a single point with fixed volume depending on number of pipes segments
Flow Direction Yes All pumps and mixer act as check valve, passive check valve available, other valves are not one-way
Pipe Integrity Yes Liquid pipes hold low pressure, but may contain both liquid and gas without consequence; Gas pipes hold high pressure, but stress and break with too much liquid
Heat Transfer Partial Liquid temperature is controlled by gas temperature (if no gas, liquid heater will not function)