Actions

Difference between revisions of "Gas"

From Unofficial Stationeers Wiki

m (New NOS Heat Capacity from Version 0.2.4138.19493 Changelog)
(Added in the new information involved in the phase change Mechanic)
Line 20: Line 20:
 
{| class="wikitable sortable"
 
{| class="wikitable sortable"
 
|-
 
|-
! Name !! Filter Color !! Molar Heat Capacity
+
! Name !! Filter Color !! Molar Heat Capacity !! Latent Heat !! Freezing point [K°/C°] !! Boiling Point at 100KPa [K°/C°] !! Minimum condensation pressure [kPa] at Temperature [K°/C°] !! Max liquid temperature [K°/C°] at Pressure [kPa]
 
|-
 
|-
| [[Carbon Dioxide]] (CO<sub>2</sub>) || Gray || 28.2
+
| [[Carbon Dioxide]] (CO<sub>2</sub>) || Gray || 28.2 || 0.6kJ/MOL || 218K°/-55.3C° || N/A. || 517kPa at 218K°/-55.3C° || 265K°/-8.1C° at 6000KPa
 
|-
 
|-
| [[Nitrogen]] (N<sub>2</sub>) || Green || 20.6
+
| [[Nitrogen]] (N<sub>2</sub>) || Green || 20.6 || 0.5kJ/MOL || 40k°/-233C° || 75K°/-198C° || 6.3kPa at 40K°/233C° || 190K°/-83C° at 6000kPa
 
|-
 
|-
| [[Nitrous Oxide]] (N<sub>2</sub>O) || Green || 37.2
+
| [[Nitrous Oxide]] (N<sub>2</sub>O) || Green || 37.2 || 4kJ/MOL || 252K°/-21C° || N/A || 800KPa at 252K°/-21C° || 431K/158C° at 2000kPa
 
|-
 
|-
| [[Oxygen]] (O<sub>2</sub>) || White || 21.1
+
| [[Oxygen]] (O<sub>2</sub>) || White || 21.1 || 0.8kJ/Mol || 56.4K°/-217C° || 90K°/-183C° || 6.3kPa at 56.4K/-217 C° || 162k°/-111C° at 6000kPa
 
|-
 
|-
| [[Pollutant]] (X) || Black || 24.8
+
| [[Pollutant]] (X) || Black || 24.8 || 2 kJ/MOL || 173k°/-99.8C° || N/A || 1800kPa at 173K°/-99.8C° || 425K°/152C° at 6000kPa
 
|-
 
|-
| [[Volatiles]] (H<sub>2</sub>) || Red || 20.4
+
| [[Volatiles]] (H<sub>2</sub>) || Red || 20.4 || 1kJ/MOL || 81.6K°/-192C° || 112K°/-162C° || 6.3kPa at 81.6K°/-192C° || 195K°/-78.1C° at 6000kPa
 +
|-
 +
| [[Steam]] (H<sub>2</sub>0) || Blue || 72 || 8kJ/MOL || 273K°/0C° || 373k°/100C° || 6.3kPa at 273K°/0C° || 643k°/370C° at 6000kPa
 
|}
 
|}
<sup>* Water is now a [[liquid]].</sup>
+
<sup>* phase change has been added to the game system and most gasses now have an associated [[liquid]] and a pure  [[Solids]] phase .</sup>
 
 
  
 
==Mixtures==
 
==Mixtures==

Revision as of 00:54, 31 July 2023

This is a disambiguation page, which lists pages which may be the intended target. If a page link referred you here, please consider editing it to point directly to the intended page.

Gas may refer to:


Gases

Name Filter Color Molar Heat Capacity Latent Heat Freezing point [K°/C°] Boiling Point at 100KPa [K°/C°] Minimum condensation pressure [kPa] at Temperature [K°/C°] Max liquid temperature [K°/C°] at Pressure [kPa]
Carbon Dioxide (CO2) Gray 28.2 0.6kJ/MOL 218K°/-55.3C° N/A. 517kPa at 218K°/-55.3C° 265K°/-8.1C° at 6000KPa
Nitrogen (N2) Green 20.6 0.5kJ/MOL 40k°/-233C° 75K°/-198C° 6.3kPa at 40K°/233C° 190K°/-83C° at 6000kPa
Nitrous Oxide (N2O) Green 37.2 4kJ/MOL 252K°/-21C° N/A 800KPa at 252K°/-21C° 431K/158C° at 2000kPa
Oxygen (O2) White 21.1 0.8kJ/Mol 56.4K°/-217C° 90K°/-183C° 6.3kPa at 56.4K/-217 C° 162k°/-111C° at 6000kPa
Pollutant (X) Black 24.8 2 kJ/MOL 173k°/-99.8C° N/A 1800kPa at 173K°/-99.8C° 425K°/152C° at 6000kPa
Volatiles (H2) Red 20.4 1kJ/MOL 81.6K°/-192C° 112K°/-162C° 6.3kPa at 81.6K°/-192C° 195K°/-78.1C° at 6000kPa
Steam (H20) Blue 72 8kJ/MOL 273K°/0C° 373k°/100C° 6.3kPa at 273K°/0C° 643k°/370C° at 6000kPa

* phase change has been added to the game system and most gasses now have an associated liquid and a pure Solids phase .

Mixtures

Name Contents Tank Color Notes
Fuel 67% H2, 33%O2 Orange Autoignition at 300C
Air 75% N2, 25% O2 White 16kPa Partial Pressure O2 minimum is required for human player breathing. Hyperoxia is not simulated.

Simulation Mechanics

  • Partial ideal gas law (PV=nRT) is simulated.
  • Fluid dynamics, thermal conductivity, phase change, the rest of the ideal gas law, and others are not simulated.
  • Thermal radiation is not simulated, but vacuum atmosphere (not rooms) will absorb a fixed amount of energy per tick. The sun adds a fixed energy per tick.
  • Each environment grid cube acts as a single point and each connected pipe network acts as a single point.
  • Insulation is perfect/infinite.
  • All pumps/mixer also act as a check valve.
  • Gas stoichiometry is not utilized. (i.e. Igniting 2H2 + O2 yields H2O instead of expected 2H2O)