Geometry Of Solar Panels and Daylight Sensors

8-chip two-axis Solar Tracking

Author: It's all over YouTube, so honestly, who knows...
Stationeers Version: 0.2.2768.13597 and up
Number of Components: 9
Accuracy: At least 98% (I've seen it go as low as 98.35% for a brief time during sunrise)
Math Formula: F(x,y) = {x, (75 ± y) / 1.5} where x is the horizontal solar angle and y is the vertical solar angle.

Design

This is about as lean as it gets for a two-axis setup. Here are the major points for why the old "12-component, two-sensor" setup is outdated:

  • The Daylight Sensor has been improved to deliver both horizontal and vertical data via variables, there's no need for two sensors
  • Changes to the solar panels has made the horizontal angle absolute, so you don't need to have circuits for correcting the horizontal angle

2-Axis-Solar-Logic-fixed.png

  • Daylight Sensor (Face data-port north for maximum efficiency)
  • Horizontal Reader (A) (IN: Daylight Sensor - VAR: Horizontal)
  • Horizontal Batch Writer (B) (IN: Horizontal Reader - OUT: Solar Panel (Dual) - VAR: Horizontal)
  • Math Processor 2 (C) (IN1: Math 1 - IN2: Memory 1.5 - OUT: Divide)
  • Vertical Reader (D) (IN: Daylight Sensor - VAR: Vertical)
  • Vertical Batch Writer (E) (IN: Math 2 - OUT: Solar Panel (Dual) - VAR: Vertical)
  • Math Processor 1 (F) (IN1: Memory 75 - IN2: Vertical Reader - OUT: Add/Subtract) (Depends on whether the solar-panels' data-ports face east or west.)
  • Memory 75 (G) (75)
  • Memory 1.5 (H) (1.5)

If you want this setup to be a one-axis tracker, just skip the green chips, and manually wrench the panels to face the sun.

Horizontal sensor orientation

Orientation of the data-port on the horizontal sensor matters! Depending on where the data-port points, the solar-panels will will do a horizontal reorientation at either midnight (north, 000), dawn (east, 090), noon (south, 180), or dusk (west, 270). The worst position is to have the data-port pointing south, as efficiency drops from 99% to ~70% during the transition. North is the position with the least impact, because the solar panels aren't generating any power when the panels transition.

The reason for this transition is that the horizontal angle goes from -179 degrees to +180 degrees. As the sun moves from +180 to -179 degrees, the solar panels do a time-consuming -359 degree move instead of an efficient +1 degree move.

Credit for alternatives: PoolSharkFOG, bti, and Fudd79

Two-axis IC alternative

This setup can be also programmed in an IC10 chip which saves power because you need only 5 chips instead of 8.

Required:

  • 1x IC10 Chip plus IC housing
  • 1x Kit (Sensor) to make a Daylight Sensor

Connect Daylight Sensor to d0, that's it! This program writes directly to both regular and heavy solar panels, and it also resets to face the sunrise when the sun goes below the horizon.

The code can be found here: https://stationeering.com/tools/ic/_vACXbmPovP (valid as of Update 0.2.2943.14662 - 2021-08-02). If your solar panel data-ports face west instead of east, replace the sub on line 23 with add, and the -90 on line 9 to 90.

NOTE: The way the reset works, the panels are turned away from the sun while there's still sunlight to soak up. So if you want to squeeze every last photon out, comment out lines 7, 14, 16, and the entire reset-block (lines 38-48).

Code provided by bti, comments and readability changes by Fudd79

9-chip 1-sensor 1-axis Solar Tracking

Authors: Wooodiii, Corvus_bkgk, Enfantcool, Baksch, Wgairborne (IC)
Properties: Accurate (average error 1.3°), Auto-reset (variant), Power conserving (variant)
Number of Components: 10-12
Math Formula: f(x) = min((x-min(x,15))/1.5, 100) where x is the solar angle.

Note: With the introduction of ecliptic solar angles, this setup no longer works well on worlds such as Vulkan and Europa which have the sun at an angle. This setup will still work on the Moon and in Space, and will be acceptable on Mars and Loulan.

This setup is accurate, giving 495-500W throughout the day, with lower output only when the sun is lower than the panels can physically aim at.

This setup adjusts for the fact that solar panels rotate through only 150 degrees. Instead of converting using 180/100, this setup converts by doing 150/100. It then clips the value at the edges, where the prior calculation would give elevations that are negative or greater than 100 (representing the fact that we would prefer the panel to track past 0 or 100, aiming all the way down to the horizon instead of stopping 15° short). The listed average error is nonzero only because of this completely unavoidable portion; the error is 0 throughout the 15°-165° portion of the day.

This setup produces the equivalent of 274W averaged over a whole day/night cycle.

Design

  • The Daylight Sensor should face the sunrise.
  • Solar panels should be rotated such that 0% vertical faces the sunrise.


Component (Name) Settings Explanation
Logic Reader (A) Daylight sensor, Solar angle Sun's angle above the horizon
Memory (15) 15 True angle of solar panels at 0 elevation
Memory (1.5) 1.5 150/100, the conversion constant from solar angle (range:15-165, i.e. 150) to panel elevation (range:0-100)
Min/Max Unit (B) min(A,15) Adjustment amount: 15, unless that would take A-B negative, in which case only enough to reach 0 (low edge case). Equivalent to min(A-B,0) but doesn't require storing 0.
Math Unit (C) A-B Adjusted solar angle
Math Unit (D) C/1.5 Conversion from solar angle to panel elevation
Memory (100) 100 Maximum possible panel elevation
Min/Max Unit (E) min(D,100) Cap elevation to 100 for solar angles past 165° (high edge case). Equivalent to doing min(A-B,165) before step D, but 100 is easier to set in memory than 165.
Batch Writer E -> Solar panels, Vertical angle Send elevation to solar panels

Accurate Solar Control.png

Auto-Reset Variant

For panels that automatically reset their facing upon sunset, use two more components, and adjust the final min/max unit:

Component (Name) Settings Explanation
Logic Reader (L) Daylight sensor, Activation 1 while daytime, 0 while nighttime
Math Unit (F) 100*L Maximum panel elevation, now 100 during day and 0 at night
(from above) Min/Max Unit (E) min(D,F) Adjusted panel elevation (high edge adjustment)

Power-Conserving Variant

To conserve power, it's possible to avoid running the entire circuit at night. A transformer can be controlled to power the main logic network above. In this way, only the two new components need to remain powered at all times.

Component (Name) Settings Explanation
Logic Reader (L) Daylight sensor, Activation As in the auto-reset variant above
Logic Writer L -> Transformer, On Transformer powers main logic network

IC Chip Version

Daylight Sensor should point at sunrise.
IC Housing's pins are set with "00" being set to the Daylight Sensor, and "01" being set to one of the panels to determine hash. ONLY USE ONE TYPE OF PANEL

Link to IC Code: [1]



4-chip 1-sensor 1-axis Approximate Solar Tracking

Author: Evie
Stationeers Version: 0.1.1068.5451
Properties: Simple, Inaccurate (Average error: 7.5°)
Number of Components: 5

Note: With the introduction of ecliptic solar angles, this setup no longer works at peak efficiency on worlds such as Mars and Europa which have the sun at an angle. This setup will still work on the Moon and in Space.

This imperfect setup is a common starting point. It starts off at 375w of power in the morning, builds up to 500w at zenith (noon) then back to 375. This is due to the fact that solars rotate through only 150 degrees of elevation and that this setup's math is correct only if they rotated through all 180 degrees of solar angle.

This setup produces the equivalent of 239W averaged over a whole day/night cycle.

Design

Solar Setup Diagram
A super compact version

Notes

  • The Daylight Sensor MUST be facing East (Sunrise), but its rotation doesn't matter.
  • Solar panels should be rotated such as that 0% VERTICAL rotation faces East/Sunrise, and 100% VERTICAL faces West/Sunset.
  • The Area Power Control is necessary for the circuit to stay powered during the night. It also hides all the modules from the rest of your system.
  • Make sure that the math unit is set to "Divide" operation.
  • Importantly, the solar input power doesn't directly connect to any of the logic writers. This not only ensures your system doesn't lose power but also prevents short-circuiting that would burn cables.
  • Using 1.7 instead of 1.8 reduces the average error of this design to 6.5° and increases overall power generation, particularly in the afternoon.

Solar Logic Cable Golf

An interesting engineering challenge is to wire up the logic with the minimum amount of cabling. The goal would be to get solar tracking (or whatever) working as early as possible by minimizing the amount of copper that must be gathered and smelted.

The rules of Cable Golf are:

  • The score is the number of Cable Coils used to correctly wire the functionality. (Straight and corner count as 1 cable; T and + count as 2 cables)
  • Chips may be placed in any orientation (upside-down math chips might conserve cables)
  • The single-plane category requires all the chips to be on coplanar faces of all frames. The multi-plane category allows the chips to be on frame faces that are at different angles (crossing an edge or surrounding a corner).
  • The number of frames needed to mount the components is part of the category (2-frame scores are separate from 3-frame scores)
  • If a component that can not be placed on the edge of a lone frame is placed on the edge between two frames, both those frames must be counted in the category.
  • If a component must be placed on a frame, that frame's surface is part of its category, even if the frame is removed afterward.
  • There must be a connection to the feed from the Power Controller, but the cables leading from the power controller (to a *single* connection point; once it branches the junction and cables are counted) that are not required for the logic to function are not counted. This power feed connection will almost certainly be a T or +, since a corner or straight section is strictly a feed and not needed to connect the logic components.
  • Cables needed to propagate the output of the Batch/Logic Writers to the top edge of a frame are counted in the score