Difference between revisions of "Powered Chutes"
From Unofficial Stationeers Wiki
m (minor change to infobox) |
m (→Chute Digital Flip Flop) |
||
Line 71: | Line 71: | ||
{{Data Parameters/row|Power|Boolean|w=0|Can be read to return if the Chute Bin is correctly powered or not, set via the power system, return 1 if powered and 0 if not|multiple=2|0|Unpowered|1|Powered}} | {{Data Parameters/row|Power|Boolean|w=0|Can be read to return if the Chute Bin is correctly powered or not, set via the power system, return 1 if powered and 0 if not|multiple=2|0|Unpowered|1|Powered}} | ||
{{Data Parameters/row|Mode|Integer|Current output direction, 0 straight through, 1 left/right}} | {{Data Parameters/row|Mode|Integer|Current output direction, 0 straight through, 1 left/right}} | ||
− | {{Data Parameters/row|Setting|Boolean|the amount of items that will be passed straight through before switching Mode}} | + | {{Data Parameters/row|Setting|Boolean|the amount of items that will be passed straight through before switching Mode, 0 will never switch Mode}} |
{{Data Parameters/row|Quantity|Boolean|The amount of items that have passed through since last opened}} | {{Data Parameters/row|Quantity|Boolean|The amount of items that have passed through since last opened}} | ||
{{Data Parameters/row|On|Boolean|The current state of the Chute Bin.|multiple=2|0|Off|1|On}} | {{Data Parameters/row|On|Boolean|The current state of the Chute Bin.|multiple=2|0|Off|1|On}} | ||
{{Data Parameters/row|RequiredPower|Integer|w=0|Idle operating power quantity, does not necessarily include extra demand power}} | {{Data Parameters/row|RequiredPower|Integer|w=0|Idle operating power quantity, does not necessarily include extra demand power}} | ||
{{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}} | {{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}} | ||
− | {{Data Parameters/row|SettingOutput|Boolean|the amount of items that will be passed to the left/right before switching Mode}} | + | {{Data Parameters/row|SettingOutput|Boolean|the amount of items that will be passed to the left/right before switching Mode, 0 will never switch Mode}} |
{{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}} | {{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}} | ||
{{Data Parameters/row|NameHash|Integer|w=0|Provides the hash value for the name of the object as a 32 bit integer.}} | {{Data Parameters/row|NameHash|Integer|w=0|Provides the hash value for the name of the object as a 32 bit integer.}} | ||
}} | }} |
Revision as of 16:05, 19 July 2024
File:ItemKitPoweredChute.png | |
Properties | |
---|---|
Stacks | Yes (10) |
Recipe | |
Created With | Autolathe, Hydraulic Pipe Bender |
Cost | 3g Iron, 2g Electrum, 2g Constantan |
Construction | |
---|---|
Placed with | Kit (Powered Chutes) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Wrench |
Item received | Kit (Powered Chutes) |
Contents
Chute
Description
Used to transport items. The Kit can be used to create 5 different variants, all of which require power and can connect to data ports.
- Chute Digital Valve Right: Allows a certain number of items through, then closes until reopened either manually or via data network.
- Chute Digital Valve Left: Allows a certain number of items through, then closes until reopened either manually or via data network.
- Chute Digital Flip Flop Splitter Right: Splits items between two directions. Ratio can be configured.
- Chute Digital Flip Flop Splitter Left: Splits items between two directions. Ratio can be configured.
- Chute Import Bin: Acts as a manual entry point to the Chute network. Can hold one item, and will not insert the item into the network until the lever on the side is pulled.
- Chute Export Bin: Acts as an exit point to the Chute network. Can hold one item, usually used with a LARrE
Recipes
Manufactory | Materials | Time | Energy |
---|---|---|---|
Autolathe | 3g Iron, 2g Electrum, 2g Constantan | 5 | 500 |
Hydraulic Pipe Bender | 3g Iron, 2g Electrum, 2g Constantan | 5 | 500 |
Recycler | 1.5g Iron, 1g Electrum, 1g Constantan | 5 | 1000 |
Chute Import/Export Bin
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Chute Bin is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | Powered | |||||
Open | Integer | Read Write
|
||||
Error | Boolean | Read
|
0 | 1 if device is in error state, otherwise 0 | ||
1 | Error | |||||
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Chute Bin. | |
1 | Locked | |||||
On | Boolean | Read Write
|
0 | Off | The current state of the Chute Bin. | |
1 | On | |||||
RequiredPower | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|
Chute Digital Valve
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Chute Bin is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | Powered | |||||
Open | Integer | Read Write
|
||||
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Chute Bin. | |
1 | Locked | |||||
Setting | Boolean | Read Write
|
||||
Quantity | Boolean | Read Write
|
||||
On | Boolean | Read Write
|
0 | Off | The current state of the Chute Bin. | |
1 | On | |||||
RequiredPower | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|
Chute Digital Flip Flop
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Chute Bin is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | Powered | |||||
Mode | Integer | Read Write
|
||||
Setting | Boolean | Read Write
|
||||
Quantity | Boolean | Read Write
|
||||
On | Boolean | Read Write
|
0 | Off | The current state of the Chute Bin. | |
1 | On | |||||
RequiredPower | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
SettingOutput | Boolean | Read Write
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|