Actions

Atmospherics

From Unofficial Stationeers Wiki

Revision as of 04:18, 27 March 2018 by 121.210.184.206 (talk) (Logic Outputs)


Kit (Atmospherics)
ItemKitAtmospherics.png
Properties
Stacks no
Recipe
Created With Hydraulic Pipe Bender, Fabricator
Cost 10g Iron, 5g Gold, 20g Copper
Atmospherics
Atmospherics front.jpg
Construction
Placed with {{{placed_with_item}}}
Placed on {{{placed_on_grid}}}

Air Conditioner Unit

Description

Used to lower and raise the temperature fed through it from the input pipe.
It has a range from -99 to 99 Celsius for the output

If the coolant pipe does not have 100kpa pressure it will divert output to coolant waste port to fill its coolant pipe

Usage

Place the Kit (Atmospherics) and run some pipes to the place you want to vent the heat. Place a few Pipe Radiators on the pipe, fill it with whatever gas mixture you want.
Make a return loop on the coolant system back to the coolant waste port for a slightly better efficiency.
It will try to draw or expel heat to the coolant mix to make the input match the desired output.

Logic Properties

These are all logic properties of this device.

Logic Parameters

These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description
Open Boolean Starts the Air Conditioner Unit, when set to 1. Stops it, when set to 0.
Mode Integer (Unknown) (Judging by the "Mode" output, it accepts values in the range 0-2.)
Lock Boolean Locks the Air Conditioner Unit, when set to 1. Unlocks it, when set to 0.
On Boolean Turns the Air Conditioner Unit on, when set to 1. Turns it off, when set to 0.

Logic Outputs

These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Air Conditioner Unit is turned on. (0 is off, 1 is on) (Identical to "On" output. This might be intended to output whether the device is receiving power or not.)
Open Boolean Returns whether the Air Conditioner Unit is running. (0 is stopped, 1 is running)
Mode Integer (Unknown) (Returns output in the range 0-2, equivalent to the input of the "Mode" parameter.)
Error Boolean Returns whether the Air Conditioner Unit is flashing an error. (0 when no error, 1 when flashing an error)
Lock Boolean Returns whether the Air Conditioner Unit is locked. (0 when not locked, 1 when locked)
On Boolean Returns whether the Air Conditioner Unit is turned on. (0 is off, 1 is on)
RequiredPower Integer Returns the current amount of power, required by the Air Conditioner, in Watts.

Filtration Unit

Description

Used to filter out specific gasses and fluids from a mixture.
it can filter out up to 2 things at once

Usage

Place the Kit (Atmospherics) and change the variant to Filtration.
Place filters in the machine for what you want to filter out.
There are three filtration pipe connections.
Filtration Input is where you connect the incoming atmosphere to be passed through the Filtration Atmospherics.
Filtration Waste is the remaining mix after extracting whatever the filters did.
Filtration Output is the filtered material for which you placed filters in the machine for.

Logic Properties

These are all logic properties of this device.

Logic Parameters

These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description
On Boolean Turns the Filtration Unit on, when set to 1. Turns it off, when set to 0.

Logic Outputs

These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Filtration Unit is turned on. (0 is off, 1 is on) (Identical to "On" output. This might be intended to output whether the device is receiving power or not.)
Error Boolean Returns whether the Filtration Unit is flashing an error. (0 when no error, 1 when flashing an error)
On Boolean Returns whether the Filtration Unit is turned on. (0 is off, 1 is on)
RequiredPower Integer Returns the current amount of power, required by the Filtration Unit, in Watts.