Large Satellite Dish
From Unofficial Stationeers Wiki
![]() | |
| Properties | |
|---|---|
| Stacks | Yes (10) |
| Recipe | |
| Created With | Electronics Printer |
| Cost | 20g Waspaloy, 50g Inconel, 100g Astroloy |
![]() | |
| Operation | |
|---|---|
| Power Usage | 100W |
| Construction | |
| Placed with | Kit (Satellite Dish) |
| Stage 1 | |
| Deconstruction | |
| Item received | Kit (Large Satellite Dish) |
Contents
Description[edit]
"The large communications unit can be used to trade with nearby vessels."
- Stationpedia
Like all satellite dishes it is used together with a Computer fitted with a Motherboard (Communications) to allow Interstellar Communications.
The Satellite Dish must be guided by Satellite Tracking onto a signal and communications may be established once the signal strength is greater than 94%
Large Satellite Dish[edit]
Data Network Properties[edit]
Click here to see/hide all the data network properties
Input Data (Write)[edit]
These are all parameters, that can be written to with different means of using logic.
| Parameter Name | Data Type | Value | Description |
|---|---|---|---|
| On | Boolean | 0 | Turns the device off. Also toggles the switch accordingly. |
| 1 | Turns the device on. Also toggles the switch accordingly. | ||
| Activate | Boolean | 0 | If the vessel's being interrogated, stop interrogating the vessel; or nothing. |
| 1 | If the vessel's has not been interrogated, start interrogating the vessel. If the vessel has been interrogated, call down the vessel to the TargetPadIndex. | ||
| Setting | Integer | 0 ~ Max watts of device. | Set output watts to the specified number. |
| Horizontal | Integer | 0 ~ 360 | Set dish's horizontal angle to the specified number. |
| Vertical | Integer | 0 ~ 90 | Set dish's vertical angle to the specified number. |
| TargetPadIndex | Integer | Sets the landing pad index for potential call down. | |
| BestContactFilter | Integer | Lock dish to track the specified ContactIDHash ONLY, set to -1 to unlock.
| |
| Update 0.2.5888.25957 - Sun 7/9/2025 /Data_Network | |||
Output Data (Read)[edit]
These are all parameters, that can be read by using different means of logic.
| Parameter Name | Data Type | Value | Description |
|---|---|---|---|
| On | Boolean | 0 | The Dish is not powered. This is the same as the physical red powerswitch located on the structure. |
| 1 | The Dish is powered. This is the same as the physical red powerswitch located on the structure. | ||
| Activate | Boolean | 0 | Read out current Activate value; if Activate == 1, it means the dish is either interrogating the vessel or the vessel is just coming down to landing pad. |
| Power | Boolean | 0 | The dish is not powered. Can be read to determine if the dish is correctly powered or not. Set by the power system, return 1 if powered and 0 if not. |
| 1 | The Dish is powered. | ||
| Setting | Integer | Read out current dish's output watts. | |
| Horizontal | Integer | Read out current dish's horizontal angle. | |
| Vertical | Integer | Read out current dish's vertical angle. | |
| RequiredPower | Integer | Idle operating power quantity. Does not include extra power during actual usage. | |
| Idle | Boolean | Read out if the dish is not moving. | |
| Idle | Boolean | 0 | Dish not moving, and not interrogating. |
| 1 | Dish is either moving or interrogating. | ||
| Error | Boolean | 0 | 1 if device is in error state, otherwise 0. |
| 1 | 1 if device is in error state, otherwise 0. | ||
| SignalStrength | Integer | The signal strength of currently tracking signal, negative value, larger is better. If the dish is moving, this value always show -1.
| |
| SignalID | Integer | The signal IDHASH of currently tracking signal. | |
| InterrogationProgress | Integer | This value only has meaning if the dish has started interrogation to the vessel. Show's percentage on the process of the interrogation. | |
| TargetPadIndex | Integer | Read out current value of target landing pad index, useful if you want to call down the vessel by code. | |
| SizeX | Integer | The length on X axis of the vessel, see SHUTTLE_TYPE. | |
| SizeZ | Integer | The length on Z axis of the vessel, see SHUTTLE_TYPE. | |
| Reagents | Integer | Total number of reagents inside the device (e.g. 92g of iron = 92). | |
| MinimumWattsToContact | Integer | The minimum watts required reaching target vessel before one can initiate interrogation. This is the requirement imposed by the vessel. | |
| WattsReachingContact | Integer | The current effective watts reached target vessel due to angle setting and dish's watts output setting. | |
| ContactTypeId | Integer | The category of the vessel, see ContactTypeID. | |
| BestContactFilter | Integer | Currently locked ContactID, or -1 if not set.
| |
| StackSize | Integer | Read out the stack Byte count of the structure. | |
| NameHash | Integer | The hash of the custom name of the structure. | |
| PrefabHash | Integer | The hash of the structure. | |
| Referenceld | Integer | Unique Reference Identifier for this object. | |
| Update 0.2.5888.25957 - Sun 7/9/2025 /Data_Network | |||