Actions

Large Satellite Dish

From Unofficial Stationeers Wiki

Revision as of 17:45, 20 January 2026 by TK421 (talk | contribs) (Created page)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Kit (Large Satellite Dish)
ItemKitSatelliteDish.png
Properties
Stacks Yes (10)
Recipe
Created With Electronics Printer
Cost 20g Waspaloy, 50g Inconel, 100g Astroloy
Large Satellite Dish
StructureSatelliteDish.png
Operation
Power Usage 100W
Construction
Placed with Kit (Satellite Dish)
Stage 1
Deconstruction
Item received Kit (Large Satellite Dish)


Description[edit]

"The large communications unit can be used to trade with nearby vessels."
- Stationpedia


Like all satellite dishes it is used together with a Computer fitted with a Motherboard (Communications) to allow Interstellar Communications.

The Satellite Dish must be guided by Satellite Tracking onto a signal and communications may be established once the signal strength is greater than 94%


Large Satellite Dish[edit]

Data Network Properties[edit]

Click here to see/hide all the data network properties

Input Data (Write)[edit]

These are all parameters, that can be written to with different means of using logic.

Parameter Name Data Type Value Description
On Boolean 0 Turns the device off. Also toggles the switch accordingly.
1 Turns the device on. Also toggles the switch accordingly.
Activate Boolean 0 If the vessel's being interrogated, stop interrogating the vessel; or nothing.
1 If the vessel's has not been interrogated, start interrogating the vessel. If the vessel has been interrogated, call down the vessel to the TargetPadIndex.
Setting Integer 0 ~ Max watts of device. Set output watts to the specified number.
Horizontal Integer 0 ~ 360 Set dish's horizontal angle to the specified number.
Vertical Integer 0 ~ 90 Set dish's vertical angle to the specified number.
TargetPadIndex Integer Sets the landing pad index for potential call down.
BestContactFilter Integer Lock dish to track the specified ContactIDHash ONLY, set to -1 to unlock.
Update 0.2.5888.25957 - Sun 7/9/2025 /Data_Network

Output Data (Read)[edit]

These are all parameters, that can be read by using different means of logic.

Parameter Name Data Type Value Description
On Boolean 0 The Dish is not powered. This is the same as the physical red powerswitch located on the structure.
1 The Dish is powered. This is the same as the physical red powerswitch located on the structure.
Activate Boolean 0 Read out current Activate value; if Activate == 1, it means the dish is either interrogating the vessel or the vessel is just coming down to landing pad.
Power Boolean 0 The dish is not powered. Can be read to determine if the dish is correctly powered or not. Set by the power system, return 1 if powered and 0 if not.
1 The Dish is powered.
Setting Integer Read out current dish's output watts.
Horizontal Integer Read out current dish's horizontal angle.
Vertical Integer Read out current dish's vertical angle.
RequiredPower Integer Idle operating power quantity. Does not include extra power during actual usage.
Idle Boolean Read out if the dish is not moving.
Idle Boolean 0 Dish not moving, and not interrogating.
1 Dish is either moving or interrogating.
Error Boolean 0 1 if device is in error state, otherwise 0.
1 1 if device is in error state, otherwise 0.
SignalStrength Integer The signal strength of currently tracking signal, negative value, larger is better.
If the dish is moving, this value always show -1.
SignalID Integer The signal IDHASH of currently tracking signal.
InterrogationProgress Integer This value only has meaning if the dish has started interrogation to the vessel.
Show's percentage on the process of the interrogation.
TargetPadIndex Integer Read out current value of target landing pad index, useful if you want to call down the vessel by code.
SizeX Integer The length on X axis of the vessel, see SHUTTLE_TYPE.
SizeZ Integer The length on Z axis of the vessel, see SHUTTLE_TYPE.
Reagents Integer Total number of reagents inside the device (e.g. 92g of iron = 92).
MinimumWattsToContact Integer The minimum watts required reaching target vessel before one can initiate interrogation.
This is the requirement imposed by the vessel.
WattsReachingContact Integer The current effective watts reached target vessel due to angle setting and dish's watts output setting.
ContactTypeId Integer The category of the vessel, see ContactTypeID.
BestContactFilter Integer Currently locked ContactID, or -1 if not set.
StackSize Integer Read out the stack Byte count of the structure.
NameHash Integer The hash of the custom name of the structure.
PrefabHash Integer The hash of the structure.
Referenceld Integer Unique Reference Identifier for this object.
Update 0.2.5888.25957 - Sun 7/9/2025 /Data_Network