LArRE
From Unofficial Stationeers Wiki
Constructing Options | LArRE Dock |
---|---|
Properties | |
Stacks | No |
Recipes | |
Electronics Printer | 10g Inconel, 5g Hastelloy, 15g Astroloy |
Logic | |
Item Hash | -1228287398 |
Item Name | ItemKitRoboticArm |
Logic Classes |
SlotClass.None SortingClass.Kits |
Operation | |
---|---|
Power Usage | 10W |
Prefab Hash | -1818718810 |
Prefab Name | StructureRoboticArmDock |
Construction | |
Placed with | Kit (LArRE) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (LArRE) |
Contents
Description
The (L)inear (Ar)ticulated (R)ail (E)ntity or LArRE can be used to plant, harvest and fertilize plants in plant trays. It can also grab items from a Chute Export Bin and drop them in a Chute Import Bin. LArRE can interact with plant trays or chute bins built under a linear rail station or built under its dock.
- Stationpedia
LArRE is a robotic arm that can interact with powered chute bins and hydroponic trays or devices.
Compared to Harvie, LArRE can be configured to care for multiple plants and distribute fertilizer. It can also be used to transport items in general.
Usage
The dock can be connected on both sides to a network of linear rails to enable LArRE to move horizontally and vertically. Linear rail stations must be positioned so that LArRE can stop and interact with the device below. The network can only be linear (i.e. without intersections).
Each station (including the dock) is assigned a number, starting at 0 with the leftmost station.
If the network is modified (by removing or adding a rail), LARrE will be teleported to its dock. LARrE is also susceptible to collisions with players and structures. If it is blocked while moving towards its target station, LArRE will stop and flash an error until the path is cleared or the target is changed.
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the LArRE Dock is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | Powered | |||||
Error | Boolean | Read
|
0 | 1 if device is in error state, otherwise 0 | ||
1 | Error | |||||
Activate | Integer | Read Write
|
||||
Setting | Integer | Read Write
|
||||
On | Boolean | Read Write
|
0 | Off | The current state of the LArRE Dock. | |
1 | On | |||||
RequiredPower | Integer | Read
|
||||
Idle | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
Index | Integer | Read
|
||||
NameHash | Integer | Read
|
Data Slots
These are all parameters, that can be read with a Slots Reader. The outputs are listed in the order a Slots Reader's "VAR" setting cycles through them.
Number | Name | Description |
---|---|---|
0 | Occupied | |
0 | OccupantHash | |
0 | Quantity | |
0 | Damage | |
0 | Class | |
0 | MaxQuantity | |
0 | PrefabHash | |
0 | SortingCLass | |
0 | ReferenceId |
Notes
- Renamed to LArRE to better align with its non-acronym name in 2024-July-22