Kit (Gas Fuel Generator)
From Unofficial Stationeers Wiki
Revision as of 10:01, 27 May 2023 by 71.202.96.81 (talk)
Revision as of 10:01, 27 May 2023 by 71.202.96.81 (talk)
Recipe | |
---|---|
Created With | Fabricator,Electronics Printer |
Cost | 50x Iron, 10x Copper |
Prefab Hash | 1165997963 |
---|---|
Construction | |
Placed with | Kit (Gas Fuel Generator) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Gas Fuel Generator) |
Contents
Description
As the big brother of the Portable Generator the Gas Generator requires fuel and outputs crazy amounts of power if you don't throttle its gas input.
Notes
- Use a pressure regulator on the input and start it as low as 0.1kpa (Use a Labeller to enter decimal values), since it can be difficult to keep cool.
- Recommended to connect to a Kit (Battery) and to automate it as backup power.
- Can be used in conjunction with a Electrolyzer to generate its fuel.
- The output is a gas mix of CO2, Pollutants, and tiny amounts of uncombusted fuel. It is not water, as would be implied by its compatibility with the Electrolyzer.
- Requires to be placed in an atmosphere to work. Minimum pressure of 20 kPA and temperature ranging between 278-328 degrees Kelvin (5-55 Celsius)
- With a standard fuel mix (33/67 O/H2) can generate up to 14kW. With NOS fuel mix (50/50 NOS/H2) this rises to 98kW with a volume of 99kpa.
- The generator has an internal volume of 10L
Videos
Simple Overview
Stationeers 98Kv Gas fuel generator
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
Parameter Name | Data Type | Description |
---|---|---|
Setting | Float | (Unknown) Affects the Setting output. |
On | Boolean | Turns the Gas Generator on, when set to 1. Turns it off, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Gas Generator is turned on and receives power. (0 for no, 1 for yes) |
Error | Boolean | Returns whether the Gas Generator is flashing an error. (0 for no, 1 for yes) |
Pressure | Float | Returns the pressure in the Gas Generator in kilo pascal. |
Temperature | Float | Returns the temperature in the Gas Generator in kelvin. |
Setting | Float | (Unknown) Affected by the Setting parameter. |
RatioOxygen | Float | Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of oxygen in the Gas Generator. |
RatioCarbonDioxide | Float | Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of carbon dioxide in the Gas Generator. |
RatioNitrogen | Float | Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of nitrogen in the Gas Generator. |
RatioPollutant | Float | Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of pollutant in the Gas Generator. |
RatioVolatiles | Float | Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of volatiles in the Gas Generator. |
RatioWater | Float | Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of water in the Gas Generator. |
Maximum | Integer | (Unknown) Returns 100. |
Ratio | Float | (Unknown) Returns 0.5. |
On | Boolean | Returns whether the Gas Generator is turned on. (0 for no, 1 for yes) |