Suit Storage
From Unofficial Stationeers Wiki
Revision as of 14:57, 7 August 2023 by TheSavageProdigy (talk | contribs) (I have clarified to users what gases are in each input port to avoid confusion.)
Recipe | |
---|---|
Created With | Hydraulic Pipe Bender, Fabricator |
Cost | 15g Iron, 5g Copper, 5g Silver |
Construction | |
---|---|
Placed with | Kit (Suit Storage) |
Placed on | Free (forced right side up) |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Suit Storage) |
Contents
Description
Used to store the EVA Suit, Helmet, Headlamp, and Spacepack. If the suit storage is powered and has pipes connected with Oxygen [O2] or Propellant [N2], it will recharge the batteries (1kW charge rate + 50w Standby\Operating cost) and equalize the Air Tank Canister and the Propellant Tank Canister with the pipesystem inside it. The wastetank will be pumped out to the pipe connected to the waste outlet.
All pipes must be connected or it will error out, it will still charge the battery in error mode.
It does not have internal pressure regulators, Must be connected to regulated O2/N2 supply.
Inputs/Outputs: Front Input is O2 Back Bottom Input is N2 Top Output is Waste
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
Parameter Name | Data Type | Description |
---|---|---|
Setting | Integer | Inherited from pump class. |
On | Boolean | Turns the device on, when set >= 1. Turns it off, when set to <1. |
Data Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the device is turned on and receives power. (0 for no, 1 for yes). |
Error | Boolean | Returns whether the device is flashing an error. (0 for no, 1 for yes). |
Setting | Integer | Inherited from pump class. |
Maximum | Integer | Inherited from pump class. |
Ratio | Integer | Inherited from pump class. |
On | Boolean | Returns whether the device is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power, required by the device, in watts. |
Data Slots
These are all parameters, that can be read with a Slots Reader. The outputs are listed in the order a Slots Reader's "VAR" setting cycles through them.
Number | Name | Description |
---|---|---|
0 | Helmet | |
1 | Suit | |
2 | Back |
Name | Data Type | Description |
---|---|---|
All | ||
Occupied | Boolean | Returns whether the slot occupied. (0 for no, 1 for yes). |
OccupantHash | Integer | Returns ItemHash of item in slot. |
MaxQuantity | Integer | Size of stack. |
Damage | Integer | Item durability in percent. |
Class | Integer | Item class ID. |
Quantity | Integer | Size of stack. |
PrefabHash | Integer | Returns ItemHash of item in slot. |
Suit | ||
ChargeRatio | Integer | Percent charge in 0-1. |
Charge | Integer | Charge in Joules. |
PressureWaste | Integer | Pressure of wastetank. |
PressureAir | Integer | Pressure of airtank. |
Back | ||
Pressure | Integer | Pressure of Jettank. |