Actions

AIMEe

From Unofficial Stationeers Wiki

Revision as of 14:54, 2 April 2022 by 5.57.195.254 (talk) (addet a note that saias that mode 0 will automatically be assigned after the robot arrives at its target)


Robot
Robot.png
Properties
Stacks No
Recipe
Created With Electronics Printer MK2
Cost 5g Gold, 5g Copper, 22g Steel, 15g Electrum, 7g Invar, 8g Constantan, 10g Astroloy

AIMEe or Automated Independent Mechanical Entity is a small mining robot that can be automated to search, mine and retrieve ores. AIMEe does get damaged by storms and can not be repaired with Duct Tape.

Robot
Robot.png
Operation
Power Usage Unknown
Construction


Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
TargetX Set the target for Mode RobotMode.PathToTarget & RobotMode.MoveToTarget
TargetY Set the target for Mode RobotMode.PathToTarget & RobotMode.MoveToTarget
TargetZ Set the target for Mode RobotMode.PathToTarget & RobotMode.MoveToTarget
Mode 0-6
On
  • robot. RobotMode.None = 0
    Do nothing (Will automatically be assigned after arriving at target)
  • RobotMode.Follow = 1
    Follow nearest player
  • RobotMode.MoveToTarget = 2
    Move to Target in straight line
  • RobotMode.Roam = 3
    Wander around looking for ores in 15 coords radius
  • RobotMode.Unload = 4
    Unload in chute input or chute bin within 3 meters \ 1.5 large grid
  • RobotMode.PathToTarget = 5
    Path(find) to Target
  • RobotMode.StorageFull = 6
    Automatic assigned state that will show when storage slots are full (not stacks)

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
PressureExternal Read external pressure in Pascal
TemperatureExternal Read external temperature in Kelvin
PositionX Read current position
PositionY Read current position
PositionZ Read current position
VelocityMagnitude
VelocityRelativeX
VelocityRelativeY
VelocityRelativeZ
Mode 0-6
Power
Error
On
MineablesInQueue
MineablesInVicinity

Data Slots

These are all parameters, that can be read with a Slots Reader. The outputs are listed in the order a Slots Reader's "VAR" setting cycles through them.

Number Name Description
0 Battery
1 IC10
2-9 Storage Internal storage slots.


Name Data Type Description
Battery Slot 0
Occupied Boolean Returns whether the slot occupied. (0 for no, 1 for yes).
OccupantHash Integer Returns ItemHash of item in slot.
MaxQuantity Integer Max Size of stack.
Damage Integer Item durability in percent.
Class Integer Item class ID.
Quantity Integer Size of stack.
ChargeRatio Integer Ratio of charge 0-1.
Charge Integer Charge in joules.
PrefabHash Integer Returns ItemHash of item in slot.
Name Data Type Description
IC10 Slot 1
Occupied Boolean Returns whether the slot occupied. (0 for no, 1 for yes).
OccupantHash Integer Returns ItemHash of item in slot.
MaxQuantity Integer Max Size of stack.
Damage Integer Item durability in percent.
Class Integer Item class ID.
Quantity Integer Size of stack.
PrefabHash Integer Returns ItemHash of item in slot.
Name Data Type Description
Inventory Slot 2-9
Occupied Boolean Returns whether the slot occupied. (0 for no, 1 for yes).
OccupantHash Integer Returns ItemHash of item in slot.
MaxQuantity Integer Max Size of stack.
Damage Integer Item durability in percent.
Class Integer Item class ID.
Quantity Integer Size of stack.
PrefabHash Integer Returns ItemHash of item in slot.