Actions

Combustion Centrifuge

From Unofficial Stationeers Wiki

Revision as of 11:49, 4 August 2024 by Emilgardis (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)


Kit (Combustion Centrifuge)
KitStructureCombustionCentrifuge.png
Constructing Options Combustion Centrifuge
Properties
Stacks No
Recipes
Autolathe (Tier Two) 20g Steel, 10g Invar, 5g Constantan
Logic
Item Hash 231903234
Item Name KitStructureCombustionCentrifuge
Logic Classes
SlotClass.None
SortingClass.Kits
Combustion Centrifuge
StructureCombustionCentrifuge.png
Operation
Power Usage 50W
Construction
Placed with Kit (Combustion Centrifuge)
Placed on Small Grid
Stage 1
StructureCombustionCentrifuge BuildState0.png
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Combustion Centrifuge)
Stage 2
StructureCombustionCentrifuge BuildState1.png
Next Stage Construction
Constructed with tool Welder
Constructed with item 2x Steel Sheets
Deconstruction
Deconstructed with Angle Grinder
Item received 2x Steel Sheets
Stage 3
Next Stage Construction
Constructed with item 1x Cable Coil
Deconstruction
Deconstructed with Wire Cutters
Item received 1x Cable Coil
The Combustion Centrifuge is a gas powered version of the Centrifuge. If a Recycler or unbalanced Furnace outputs reagent mixture rather than the desired ingots, a centrifuge allows you to reclaim the raw ore.

It also refines Dirty Ore produced from the Deep Miner and Dirty Ore produced from the Rocket Miner. A combustible fuel mix should be supplied to the gas input, and waste gasses should be vented from the output. The machine's RPMs must be controlled via the throttle and combustion limiter levers. If the Combustion Centrifuge gains, or loses, RPMs too fast it will experience stress, and eventually grind to a halt. Higher RPMs directly result in faster processing speeds. The throttle lever controls the amount of fuel being pulled into the machine, increasing the temperature inside the engine, and leading to an increase in RPM. The limiter lever influences the speed of the combustion, and how much uncombusted gas is in the exhaust. Ejecting ore from the Combustion Centrifuge while it is at high RPMs will result in additional stress build up. If turned off while not stressed, the machine will automatically start to brake, and reduce RPMs in a controlled manner.

- Stationpedia

Description

The combustion centrifuge is a gas powered version of the Centrifuge. A combustible fuel mix should be supplied to the gas input, and waste gasses should be vented from the output. The machine's RPM's must be controlled via the throttle and combustion limiter levers. If the Combustion Centrifuge gains, or loses, RPMs too fast it will experience stress, and eventually grind to a halt. Higher RPMs directly result in faster processing speeds.

The throttle lever controls the amount of fuel being pulled into the machine, increasing the temperature inside the engine, and leading to an increase in RPM. The limiter lever influences the speed of combustion, and how much uncombusted gas is in the exhaust.

Ejecting ore from the Combustion Centrifuge while it is at high RPMs will result in additional stress build up. If turned off, while not stressed, the machine will automatically start to brake, and reduce RPMs in a controlled manner.

The Combustion Centrifuge has a socket for an IC10 chip, similar to the Atmospherics machine. It comes with two device ports, d0 and d1, for connecting to other devices. To change or set a device, use a screwdriver to cycle through devices found on the machine's data network.

Important

Can be boosted by Nitrous Oxide in fuel mixture, but don't make mixture to autoigniting, you can blow everything up with overpressured Gas Canister(perhaps, centrifuge too)!

Throttle

Every tick up to 0.01 moles of gas will be pulled in to the machine from the input pipe network. The Throttle parameter linearly controls how much gas to pull in, inputMoles = 0.01*Throttle/100. The Throttle value is rounded to the nearest multiple of 10 when set over the Data Network.

Combustion Limiter

On each tick the Combustion Centrifuge will manually combust up to 75% of the fuel mixture in its internal atmosphere. This happens on the remaining fuel after natural combustion takes place as described in Volatiles. The portion of fuel manually combusted each tick is clamp((Limiter/10)^2 * 0.0075, 0.001, 1). The Combustion Limiter value is rounded to the nearest multiple of 10 when set over the Data Network.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).

Click here to see/hide all the data network properties
Parameter Name Data Type Access Value Description
Power Boolean
Read
0 Unpowered Can be read to return if the Combustion Centrifuge is correctly powered or not, set via the power system, return 1 if powered and 0 if not
1 Powered
Open Integer
Read Write
0 Closed 1 if device is open, otherwise 0
1 Open
Error Boolean
Read
0

1 if device is in error state, otherwise 0
1 Error
Pressure Float
Read
The current pressure reading of the Combustion Centrifuge
Temperature Integer
Read
The current temperature reading of the Combustion Centrifuge
Lock Boolean
Read Write
0 Unlocked Disable manual operation of the Combustion Centrifuge.
1 Locked
Reagents Integer
Read
Total number of reagents recorded by the Combustion Centrifuge
RatioOxygen Float
Read
0.0 to 1.0 The ratio of Oxygen in device atmosphere
RatioCarbonDioxide Float
Read
0.0 to 1.0 The ratio of Carbon Dioxide in device atmosphere
RatioNitrogen Float
Read
0.0 to 1.0 The ratio of Nitrogen in device atmosphere
RatioPollutant Float
Read
0.0 to 1.0 The ratio of Pollutant in device atmosphere
RatioVolatiles Float
Read
0.0 to 1.0 The ratio of Volatiles in device atmosphere
RatioWater Float
Read
0.0 to 1.0 The ratio of Water in device atmosphere
On Boolean
Read Write
0 Off The current state of the Combustion Centrifuge.
1 On
RequiredPower Integer
Read
Idle operating power quantity, does not necessarily include extra demand power
ClearMemory Integer
Write
When set to 1, clears the counter memory (e.g. ExportCount). Will set itself back to 0 when actioned
ExportCount Integer
Read
How many items exported since last ClearMemory
ImportCount Integer
Read
How many items imported since last ClearMemory
TotalMoles Float
Read
Returns the total moles of the Combustion Centrifuge
RatioNitrousOxide Float
Read
0.0 to 1.0 The ratio of Nitrous Oxide in device atmosphere
PrefabHash Integer
Read
The hash of the structure
Combustion Boolean
Read
0 or 1 Assess if the atmosphere is on fire. Returns 1 if atmosphere is on fire, 0 if not.
PressureInput Float
Read
The current pressure reading of the Combustion Centrifuge's Input Network
TemperatureInput Float
Read
The current temperature reading of the Combustion Centrifuge's Input Network
RatioOxygenInput Float
Read
0.0 to 1.0 The ratio of Oxygen in device's input network
RatioCarbonDioxideInput Float
Read
0.0 to 1.0 The ratio of Carbon Dioxide in device's input network
RatioNitrogenInput Float
Read
0.0 to 1.0 The ratio of Nitrogen in device's input network
RatioPollutantInput Float
Read
0.0 to 1.0 The ratio of Pollutant in device's input network
RatioVolatilesInput Float
Read
0.0 to 1.0 The ratio of Volatiles in device's input network
RatioWaterInput Float
Read
0.0 to 1.0 The ratio of Water in device's input network
RatioNitrousOxideInput Float
Read
0.0 to 1.0 The ratio of Nitrous Oxide in device's input network
TotalMolesInput Float
Read
Returns the total moles of the Combustion Centrifuge's Input Network
PressureOutput Float
Read
The current pressure reading of the Combustion Centrifuge's Output Network
TemperatureOutput Float
Read
The current temperature reading of the Combustion Centrifuge's Output Network
RatioOxygenOutput Float
Read
0.0 to 1.0 The ratio of Oxygen in device's Output network
RatioCarbonDioxideOutput Float
Read
0.0 to 1.0 The ratio of Carbon Dioxide in device's Output network
RatioNitrogenOutput Float
Read
0.0 to 1.0 The ratio of Nitrogen in device's Output network
RatioPollutantOutput Float
Read
0.0 to 1.0 The ratio of Pollutant in device's Output network
RatioVolatilesOutput Float
Read
0.0 to 1.0 The ratio of Volatiles in device's Output network
RatioWaterOutput Float
Read
0.0 to 1.0 The ratio of Water in device's Output network
RatioNitrousOxideOutput Float
Read
0.0 to 1.0 The ratio of Nitrous Oxide in device's Output network
TotalMolesOutput Float
Read
Returns the total moles of the Combustion Centrifuge's Output Network
CombustionInput Boolean
Read
0 or 1 Assess if the atmosphere is on fire. Returns 1 if device's input network is on fire, 0 if not.
CombustionOutput Boolean
Read
0 or 1 Assess if the atmosphere is on fire. Returns 1 if device's Output network is on fire, 0 if not.
CombustionLimiter Integer
Read Write
Retards the rate of combustion inside the machine (range: 0-100), with 0 being the slowest rate of combustion and 100 being the fastest
Throttle Integer
Read Write
Increases the rate at which the machine works (range: 0-100)
Rpm Integer
Read
The number of revolutions per minute that the Combustion Centrifuge's spinning mechanism is doing
Stress Integer
Read
Machines get stressed when working hard. When Stress reaches 100 the machine will automatically shut down
RatioLiquidNitrogen Float
Read
0.0 to 1.0 The ratio of Liquid Nitrogen in device atmosphere
RatioLiquidNitrogenInput Float
Read
0.0 to 1.0 The ratio of Liquid Nitrogen in device's input network
RatioLiquidNitrogenOutput Float
Read
0.0 to 1.0 The ratio of Liquid Nitrogen in device's Output network
RatioLiquidOxygen Float
Read
0.0 to 1.0 The ratio of Liquid Oxygen in device's Atmosphere
RatioLiquidOxygenInput Float
Read
0.0 to 1.0 The ratio of Liquid Oxygen in device's Input Atmosphere
RatioLiquidOxygenOutput Float
Read
0.0 to 1.0 The ratio of Liquid Oxygen in Combustion Centrifuge's Output Atmosphere
RatioLiquidVolatiles Float
Read
0.0 to 1.0 The ratio of Liquid Volatiles in device's Atmosphere
RatioLiquidVolatilesInput Float
Read
0.0 to 1.0 The ratio of Liquid Volatiles in device's Input Atmosphere
RatioLiquidVolatilesOutput Float
Read
0.0 to 1.0 The ratio of Liquid Volatiles in Combustion Centrifuge's Output Atmosphere
RatioSteam Float
Read
0.0 to 1.0 The ratio of Steam in device's Atmosphere
RatioSteamInput Float
Read
0.0 to 1.0 The ratio of Steam in device's Input Atmosphere
RatioSteamOutput Float
Read
0.0 to 1.0 The ratio of Steam in Combustion Centrifuge's Output Atmosphere
RatioLiquidCarbonDioxide Float
Read
0.0 to 1.0 The ratio of Liquid Carbon Dioxide in device's Atmosphere
RatioLiquidCarbonDioxideInput Float
Read
0.0 to 1.0 The ratio of Liquid Carbon Dioxide in device's Input Atmosphere
RatioLiquidCarbonDioxideOutput Float
Read
0.0 to 1.0 The ratio of Liquid Carbon Dioxide in Combustion Centrifuge's Output Atmosphere
RatioLiquidPollutant Float
Read
0.0 to 1.0 The ratio of Liquid Pollutant in device's Atmosphere
RatioLiquidPollutantInput Float
Read
0.0 to 1.0 The ratio of Liquid Pollutant in device's Input Atmosphere
RatioLiquidPollutantOutput Float
Read
0.0 to 1.0 The ratio of Liquid Pollutant in Combustion Centrifuge's Output Atmosphere
RatioLiquidNitrousOxide Float
Read
0.0 to 1.0 The ratio of Liquid Nitrous Oxide in device's Atmosphere
RatioLiquidNitrousOxideInput Float
Read
0.0 to 1.0 The ratio of Liquid Nitrous Oxide in device's Input Atmosphere
RatioLiquidNitrousOxideOutput Float
Read
0.0 to 1.0 The ratio of Liquid Nitrous Oxide in Combustion Centrifuge's Output Atmosphere
ReferenceId Integer
Read
Unique Reference Identifier for this object
RatioHydrogen Float
Read
0.0 to 1.0 DEPRECATED
RatioLiquidHydrogen Float
Read
0.0 to 1.0 DEPRECATED
RatioPollutedWater Float
Read
0.0 to 1.0 The ratio of polluted water in device atmosphere
NameHash Integer
Read
Provides the hash value for the name of the object as a 32 bit integer.
Template:Slots
Slot Name Type Index
Import None 0
Export None 1
Programmable Chip Programmable Chip 2

Template:Connections

Connection Name Index
Chute Input 0
Chute Output 1
Data 2
Power 3
Pipe Input 4
Pipe Input 5