Difference between revisions of "Atmospheric Components Quick Reference"
From Unofficial Stationeers Wiki
TheNicestGuy (talk | contribs) (Add storage components.) |
TheNicestGuy (talk | contribs) (Split large and small tank. Improve phrasing of functions.) |
||
Line 7: | Line 7: | ||
| [[Pipes|Pipe]] (various shapes) || [[Pipes|Kit (Pipe)]] || colspan="2"|2-6 generic || No || No || No || - || Provide a pathway. | | [[Pipes|Pipe]] (various shapes) || [[Pipes|Kit (Pipe)]] || colspan="2"|2-6 generic || No || No || No || - || Provide a pathway. | ||
|- | |- | ||
− | | [[Pipe Valve]] || [[Pipe Valve|Kit (Pipe Valve)]] || colspan="2"|2 generic || No || Manual || No|| -|| Open/close flow manually. | + | | [[Pipe Valve]] || [[Pipe Valve|Kit (Pipe Valve)]] || colspan="2"|2 generic || No || Manual only || No|| -|| Open/close flow manually. |
|- | |- | ||
| [[Pipe Digital Valve]] || [[Pipe Digital Valve|Kit (Digital Valve)]] || colspan="2"|2 generic || No || Yes || No || 25W || Open/close flow using [[Kit (Logic I/O)|logic circuits]]. | | [[Pipe Digital Valve]] || [[Pipe Digital Valve|Kit (Digital Valve)]] || colspan="2"|2 generic || No || Yes || No || 25W || Open/close flow using [[Kit (Logic I/O)|logic circuits]]. | ||
Line 17: | Line 17: | ||
| [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at input. | | [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at input. | ||
|- | |- | ||
− | | [[Pipe Gas Mixer]] || [[Pipe Gas Mixer|Kit (Gas Mixer)]] || 2 || 1 || Yes || Yes || Yes<sup>1</sup> || 100W || Combine two input mixes into one output mix, at an adjustable ratio. | + | | [[Pipe Gas Mixer]] || [[Pipe Gas Mixer|Kit (Gas Mixer)]] || 2 || 1 || Yes || Yes || Yes<sup>1</sup> || 100W || Mix fluids: Combine two input mixes into one output mix, at an adjustable ratio. |
|- | |- | ||
− | | [[Kit (Atmospherics) Filtration|Filtration]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || 5W || Separate an input mix into a pure output and a "leftover" output. | + | | [[Kit (Atmospherics) Filtration|Filtration]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || 5W || Sort fluids: Separate an input mix into a pure output and a "leftover" output. |
|- | |- | ||
− | | [[Kit (Atmospherics) Electrolyzer|Electrolyzer]] || [[Kit (Atmospherics)]] || 1 || 1 || Yes || Yes || Yes || 1,400W || From input [[water|H<sub>2</sub>O]], output mixed [[Oxygen|O<sub>2</sub>]] and [[Volatiles]]. | + | | [[Kit (Atmospherics) Electrolyzer|Electrolyzer]] || [[Kit (Atmospherics)]] || 1 || 1 || Yes || Yes || Yes || 1,400W || Create fuel: From input [[water|H<sub>2</sub>O]], output mixed [[Oxygen|O<sub>2</sub>]] and [[Volatiles]]. |
|- | |- | ||
| [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || 7,000W, varies || Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs. | | [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || 7,000W, varies || Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs. | ||
|- | |- | ||
− | | [[Wall Cooler]] || [[Wall Cooler|Kit (Wall Cooler)]] || space || 1 || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || ? || Actively remove heat from a space into a pipe. | + | | [[Wall Cooler]] || [[Wall Cooler|Kit (Wall Cooler)]] || space || 1 || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || ? || Cool a space: Actively remove heat from a space into a pipe. |
|- | |- | ||
| [[Active Vent]] || [[Active Vent|Kit (Active Vent)]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe. | | [[Active Vent]] || [[Active Vent|Kit (Active Vent)]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe. | ||
Line 31: | Line 31: | ||
| [[Passive Vent]] || [[Passive Vent|Kit (Passive Vent)]] || colspan="2"|1 pipe, 1 space || No || No || No || - || Equalize pressure between a space and a pipe. | | [[Passive Vent]] || [[Passive Vent|Kit (Passive Vent)]] || colspan="2"|1 pipe, 1 space || No || No || No || - || Equalize pressure between a space and a pipe. | ||
|- | |- | ||
− | | [[Gas Tank Storage]] || [[Gas Tank Storage|Kit (Canister Storage)]] || colspan="2"|1 generic || No || No || No || - || Attach pipes to [[Gas Canister]]s (removable, inventory-portable fluid storage). | + | | [[Gas Tank Storage]] || [[Gas Tank Storage|Kit (Canister Storage)]] || colspan="2"|1 generic || No || No || No || - || Small storage: Attach pipes to [[Gas Canister]]s (removable, inventory-portable fluid storage). |
|- | |- | ||
− | | [[Tank Connector]] || [[Tank Connector|Kit (Tank Connector)]] || colspan="2"|1 generic || No || No || No || - || Attach pipes to [[Portable Tank]]s (removable, luggable fluid storage), and also to [[Portable Air Scrubber]]s and [[Portable Air Conditioner]]s. | + | | [[Tank Connector]] || [[Tank Connector|Kit (Tank Connector)]] || colspan="2"|1 generic || No || No || No || - || Medium storage: Attach pipes to [[Portable Tank]]s (removable, luggable fluid storage), and also to [[Portable Air Scrubber]]s and [[Portable Air Conditioner]]s. |
|- | |- | ||
− | | [[Tank]] (Large | + | | [[Tank|Small Tank]] || [[Tank|Kit (Tank)]] || colspan="2"|1 generic || No || Logic only? || No || - || Permanent, high-capacity fluid storage. |
+ | |- | ||
+ | | [[Tank|Large Tank]] || [[Tank|Kit (Tank)]] × 5 || colspan="2"|1 generic || No || Logic only? || No || - || Permanent, super-capacity fluid storage. | ||
|} | |} | ||
Revision as of 11:57, 26 May 2020
This is a quick reference to the various components of a piped-fluid network.
Component | Kit | Inputs | Outputs | One-way? | Switched? | Compressor? | Max. Power | Primary Function |
---|---|---|---|---|---|---|---|---|
Pipe (various shapes) | Kit (Pipe) | 2-6 generic | No | No | No | - | Provide a pathway. | |
Pipe Valve | Kit (Pipe Valve) | 2 generic | No | Manual only | No | - | Open/close flow manually. | |
Pipe Digital Valve | Kit (Digital Valve) | 2 generic | No | Yes | No | 25W | Open/close flow using logic circuits. | |
Pipe Volume Pump | Kit (Volume Pump) | 1 | 1 | Yes | Yes | Yes | 800W, varies | Pump fluid at adjustable rate. |
Pressure Regulator | Kit (Pressure Regulator) | 1 | 1 | Yes | Yes | Yes | 100W | Achieve target pressure at output. |
Back Pressure Regulator | Kit (Pressure Regulator) | 1 | 1 | Yes | Yes | Yes | 100W | Achieve target pressure at input. |
Pipe Gas Mixer | Kit (Gas Mixer) | 2 | 1 | Yes | Yes | Yes1 | 100W | Mix fluids: Combine two input mixes into one output mix, at an adjustable ratio. |
Filtration | Kit (Atmospherics) | 1 | 2 | Yes | Yes | Yes | 5W | Sort fluids: Separate an input mix into a pure output and a "leftover" output. |
Electrolyzer | Kit (Atmospherics) | 1 | 1 | Yes | Yes | Yes | 1,400W | Create fuel: From input H2O, output mixed O2 and Volatiles. |
Air Conditioner | Kit (Atmospherics) | 1 | 2 | Yes | Yes | Yes | 7,000W, varies | Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs. |
Wall Cooler | Kit (Wall Cooler) | space | 1 | Yes, for heat2 | Yes, for heat2 | Yes, for heat2 | ? | Cool a space: Actively remove heat from a space into a pipe. |
Active Vent | Kit (Active Vent) | 1 pipe, 1 space | Yes, reversable | Yes | Yes | 100W | Pump pressure between a space and a pipe. | |
Passive Vent | Kit (Passive Vent) | 1 pipe, 1 space | No | No | No | - | Equalize pressure between a space and a pipe. | |
Gas Tank Storage | Kit (Canister Storage) | 1 generic | No | No | No | - | Small storage: Attach pipes to Gas Canisters (removable, inventory-portable fluid storage). | |
Tank Connector | Kit (Tank Connector) | 1 generic | No | No | No | - | Medium storage: Attach pipes to Portable Tanks (removable, luggable fluid storage), and also to Portable Air Scrubbers and Portable Air Conditioners. | |
Small Tank | Kit (Tank) | 1 generic | No | Logic only? | No | - | Permanent, high-capacity fluid storage. | |
Large Tank | Kit (Tank) × 5 | 1 generic | No | Logic only? | No | - | Permanent, super-capacity fluid storage. |
Kit: The item used to build the component. All of these items are manufactured with a Hydraulic Pipe Bender or Fabricator, except where noted.
One-way: Does the component prevent fluid from flowing the wrong way, from output to input?
Switched: Does it prevent all flow when switched off or unpowered? Except where noted, switched components can be switched either manually or using logic circuits.
Compressor: Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output, or it does not enable any pressure changes.
Note 1: While the Pipe Gas Mixer will actively compress from output to input, it will stop when either input is empty, to preserve the mix ratio.
Note 2: The Wall Cooler's one-way, switched, and "compressor" qualities apply only to the heat exchange. It does not directly affect the pressure or flow in its attached pipe.