Difference between revisions of "Atmospherics"
From Unofficial Stationeers Wiki
(document which slot is which) |
(add some new filter data outputs) |
||
Line 108: | Line 108: | ||
|- | |- | ||
! Output Name !! Data Type !! Description | ! Output Name !! Data Type !! Description | ||
+ | |- | ||
+ | | CombustionInput | ||
+ | |- | ||
+ | | CombustionOutput | ||
+ | |- | ||
+ | | CombustionOutput2 | ||
|- | |- | ||
| Power || Boolean || Returns whether the Filtration Unit is turned on and receives power. (0 for no, 1 for yes) | | Power || Boolean || Returns whether the Filtration Unit is turned on and receives power. (0 for no, 1 for yes) | ||
|- | |- | ||
| Error || Boolean || Returns whether the Filtration Unit is flashing an error. (0 for no, 1 for yes) | | Error || Boolean || Returns whether the Filtration Unit is flashing an error. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | Lock | ||
+ | |- | ||
+ | | Maximum | ||
+ | |- | ||
+ | | Mode || Integer || 0=Idle, 1=Active | ||
|- | |- | ||
| On || Boolean || Returns whether the Filtration Unit is turned on. (0 for no, 1 for yes) | | On || Boolean || Returns whether the Filtration Unit is turned on. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | Open | ||
+ | |- | ||
+ | | OperationalTemperatureEfficiency | ||
|- | |- | ||
| RequiredPower || Integer || Returns the current amount of power, required by the Filtration Unit, in Watts. | | RequiredPower || Integer || Returns the current amount of power, required by the Filtration Unit, in Watts. | ||
|- | |- | ||
| PrefabHash || Integer || The Hash of the structure. | | PrefabHash || Integer || The Hash of the structure. | ||
+ | |- | ||
+ | | PressureEfficiency || Float | ||
|- | |- | ||
| PressureInput || Float || the pressure on the input pipe | | PressureInput || Float || the pressure on the input pipe | ||
Line 170: | Line 188: | ||
|- | |- | ||
| Setting | | Setting | ||
+ | |- | ||
+ | | TemperatureDifferencialEfficiency || Float || a value from 0..1.0 indicating the efficiency based on the temperature differential between the "waste" output and the conditioned air stream. This is not updated while the unit is Idle. | ||
|- | |- | ||
| TemperatureInput | | TemperatureInput |
Revision as of 22:27, 3 September 2022
Properties | |
---|---|
Stacks | no |
Recipe | |
Created With | Hydraulic Pipe Bender, Fabricator |
Cost | 10g Iron, 5g Gold, 20g Copper |
Air Conditioner Unit
Operation | |
---|---|
Power Usage | Up to 7000W based on temperature difference |
Construction | |
Placed with | Kit (Atmospherics) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Atmospherics) |
Description
Used to lower and raise the temperature fed through it from the input pipe.
It has a range from -200 to 200 Celsius for the output
If the coolant pipe does not have 100kpa pressure it will divert output to coolant waste port to fill its coolant pipe
Usage
Place the Kit (Atmospherics) and run some pipes to the place you want to vent the heat. Place a few Pipe Radiators on the pipe, fill it with whatever gas mixture you want.
Make a return loop on the coolant system back to the coolant waste port for slightly better efficiency.
It will try to draw or expel heat to the coolant mix to make the input match the desired output.
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Starts the Air Conditioner Unit, when set to 1. Stops it, when set to 0. (This seems to work only with Batch Writer and not with Logic Writer - tested on game ver: v0.1.1362.6552). |
Mode | Integer | (Unknown) (Judging by the "Mode" output, it accepts values in the range 0-2.) |
Lock | Boolean | Locks the Air Conditioner Unit, when set to 1. Unlocks it, when set to 0. |
On | Boolean | Turns the Air Conditioner Unit on, when set to 1. Turns it off, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Air Conditioner Unit is turned on and receives power. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Air Conditioner Unit is running. (0 for no, 1 for yes) |
Mode | Integer | (Unknown) (Returns output in the range 0-2, equivalent to the input of the "Mode" parameter.) |
Error | Boolean | Returns whether the Air Conditioner Unit is flashing an error. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the Air Conditioner Unit is locked. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Air Conditioner Unit is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power, required by the Air Conditioner, in Watts. |
Filtration
Operation | |
---|---|
Power Usage | 10W |
Construction | |
Placed with | Kit (Atmospherics) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Atmospherics) |
Description
Used to filter out specific gasses and fluids from a mixture.
it can filter out up to 2 things at once
Pumps filter gasses through itself.
Usage
Place the Kit (Atmospherics) and change the variant to Filtration.
Place filters in the machine for what you want to filter out.
There are three filtration pipe connections.
Filtration Input is where you connect the incoming atmosphere to be passed through the Filtration Atmospherics.
Filtration Unfiltered is the remaining mix after extracting whatever the filters did.
Filtration Filtered is the filtered material for which you placed filters in the machine for.
Be aware that the filtration unit unrealistically has an infinitely powerful pump integrated into its output port. That means as long as it is turned on and there is gas to filter out from the input it will pump that filtered out gas into the output pipe network (no matter how high the pressure in that output pipe network already is!). So eventually that pipe network will burst (around 60 MPa) unless you provide some sort of pop-off valve (e.g. a combination of a back-pressure regulator and a passive vent) or use a pipe analyzer and some logic to turn the filtration unit off when a certain amount of pressure is exceeded in the output pipe network. The filtration system can handle an input gas flow of just over 2.3L from a volume pump.
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
On | Boolean | Turns the Filtration Unit on, when set to 1. Turns it off, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Logic
Output Name | Data Type | Description |
---|---|---|
CombustionInput | ||
CombustionOutput | ||
CombustionOutput2 | ||
Power | Boolean | Returns whether the Filtration Unit is turned on and receives power. (0 for no, 1 for yes) |
Error | Boolean | Returns whether the Filtration Unit is flashing an error. (0 for no, 1 for yes) |
Lock | ||
Maximum | ||
Mode | Integer | 0=Idle, 1=Active |
On | Boolean | Returns whether the Filtration Unit is turned on. (0 for no, 1 for yes) |
Open | ||
OperationalTemperatureEfficiency | ||
RequiredPower | Integer | Returns the current amount of power, required by the Filtration Unit, in Watts. |
PrefabHash | Integer | The Hash of the structure. |
PressureEfficiency | Float | |
PressureInput | Float | the pressure on the input pipe |
PressureOutput | Float | the pressure on the filtered output pipe |
PressureOutput2 | Float | the pressure on the waste output pipe |
Ratio | Float | |
RatioCarbonDioxideInput | ||
RatioCarbonDioxideOutput | ||
RatioCarbonDioxideOutput2 | ||
RatioNitrogenInput | ||
RatioNitrogenOutput | ||
RatioNitrogenOutput2 | ||
RatioNitrousOxideInput | ||
RatioNitrousOxideOutput | ||
RatioNitrousOxideOutput2 | ||
RatioOxygenInput | ||
RatioOxygenOutput | ||
RatioOxygenOutput2 | ||
RatioPollutantInput | ||
RatioPollutantOutput | ||
RatioPollutantOutput2 | ||
RatioVolatilesInput | ||
RatioVolatilesOuput | ||
RatioVolatilesOuput2 | ||
RatioWaterInput | ||
RatioWaterOutput | ||
RatioWaterOutput2 | ||
Setting | ||
TemperatureDifferencialEfficiency | Float | a value from 0..1.0 indicating the efficiency based on the temperature differential between the "waste" output and the conditioned air stream. This is not updated while the unit is Idle. |
TemperatureInput | ||
TemeratureOutput | ||
TemeratureOutput2 | ||
TotalMolesInput | ||
TotalMolesOutput | ||
TotalMolesOutput2 |
Logic Slots
Slot 0 and 1 are the two gas filters. Slot 2 is the programmable chip
Output Name | Data Type | Description |
---|---|---|
Occupied | Boolean | Returns whether the slot is occupied. (0 for no, 1 for yes) |
OccupantHash | Integer | Returns the hash of the object in the slot. |
Quantity | Integer | Returns the current quantity, such as stack size, of the item in the slot. |
Damage | Integer | Returns the damage state of the item in the slot. |
Class | Integer | Returns an integer representing the class of object. |
MaxQuanity | Integer | Returns max stack size of the item in the slot. |
PrefabHash | Integer | Returns the hash of the structure in the slot. |
Electrolyzer
Operation | |
---|---|
Power Usage | 1200W |
Construction | |
Placed with | Kit (Atmospherics) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Atmospherics) |
Description
Used to separate water (H2O) into H2 and O2 in a 2 to 1 ratio (perfect fuel).
Usage
Place the Kit (Atmospherics) and change the variant to Electrolyzer.
There are two pipe connections.
Electrolyzer Input is where you connect the incoming water.
Electrolyzer Output is where the H2 and O2 comes out mixed together.
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Lock | Boolean | Locks the Electrolyzer , when set to 1. Unlocks it, when set to 0. |
On | Boolean | Turns the Electrolyzer on, when set to 1. Turns it off, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Electrolyzer is turned on and receives power. (0 for no, 1 for yes) |
Error | Boolean | Returns whether the Electrolyzer is flashing an error. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the Electrolyzer is locked. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Electrolyzer is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power, required by the Electrolyzer, in Watts. |
Hydrogen Combustor
The hydrogen combustor takes a fuel mix (H2+O2), and generates water, a *lot* of heat, and waste gasses.
Limiting inflow is *highly* recommended, due to the massive amounts of heat generated.