Difference between revisions of "Constructionkit (Chutes)"
From Unofficial Stationeers Wiki
LordJakson (talk | contribs) (Redirected page to Chutes) |
Ipottinger (talk | contribs) (Corrected name from Chutes) |
||
Line 1: | Line 1: | ||
− | # | + | [[Category:Data Network]] |
+ | {{Itembox | ||
+ | | image = [[File:ItemKitChute.png]] | ||
+ | | name = Constructionkit (Chutes) | ||
+ | | createdwith = [[Autolathe]], [[Fabricator]], [[Hydraulic Pipe Bender]] | ||
+ | | cost = 1g [[Iron]]* | ||
+ | | stacks = 10 | ||
+ | }} | ||
+ | {{Structurebox | ||
+ | | name = Chute | ||
+ | | image = | ||
+ | | dectool = [[Wrench]] | ||
+ | | placement = Small Grid | ||
+ | }} | ||
+ | |||
+ | == Description == | ||
+ | Used to transport items. The Kit can be used to create 7 different variants, some of them are able to connect to power and logic network. | ||
+ | |||
+ | == Recipes ==<!--T:3--> | ||
+ | {{Recipe | ||
+ | |{{Recipe/row |machine = Autolathe |mats = 3g [[Iron]] |time = 5 |energy = 500}} | ||
+ | |{{Recipe/row |machine = Fabricator |mats = 1g [[Iron]] |time = 1 |energy = 500}} | ||
+ | |{{Recipe/row |machine = Hydraulic Pipe Bender |mats = 1g [[Iron]] |time = 5 |energy = 500}} | ||
+ | |{{Recipe/row |machine = Recycler |mats = 1,5g [[Iron]] |time = 5 |energy = 1000}} | ||
+ | }} | ||
+ | |||
+ | == Data Network Properties == | ||
+ | These are all [[:Category:Data Network|Data Network]] properties of this devices. | ||
+ | |||
+ | === Chute Bin === | ||
+ | |||
+ | ==== Data Parameters ==== | ||
+ | These are all parameters, that can be written to with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]]. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them. | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! Parameter Name !! Data Type !! Description | ||
+ | |- | ||
+ | | Open || Boolean || Opens the Chute Bin, when set to 1. Closes it, when set to 0. | ||
+ | |- | ||
+ | | On || Boolean || Turns the Chute Bin on when set to 1. Turns it off, when set to 0. | ||
+ | |} | ||
+ | |||
+ | ==== Data Outputs ==== | ||
+ | These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]]. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them. | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! Output Name !! Data Type !! Description | ||
+ | |- | ||
+ | | Power || Boolean || Returns whether the Chute Bin is turned on and receives power. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | Open || Boolean || Returns whether the Chute Bin is open. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | Error || Boolean || Returns whether the Chute Bin is flashing an error. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | On || Boolean || Returns whether the Chute Bin is turned on. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | RequiredPower || Integer || Returns the current amount of power, required by the Chute Bin, in watts. | ||
+ | |} | ||
+ | |||
+ | === Chute Outlet === | ||
+ | |||
+ | ==== Data Parameters ==== | ||
+ | These are all parameters, that can be written to with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]]. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them. | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! Parameter Name !! Data Type !! Description | ||
+ | |- | ||
+ | | Open || Boolean || Opens the Chute Outlet when set to 1. | ||
+ | |- | ||
+ | | Lock || Boolean || Locks the Chute Outlet when set to 1. Unlocks it, when set to 0. | ||
+ | |} | ||
+ | |||
+ | ==== Data Outputs ==== | ||
+ | These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]]. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them. | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! Output Name !! Data Type !! Description | ||
+ | |- | ||
+ | | Open || Boolean || Returns whether the Chute Outlet is open. (0 for no, 1 for yes) This only returns 1 briefly, when the Chute Outlet opens. | ||
+ | |- | ||
+ | | Lock || Boolean || Returns whether the Chute Outlet is locked. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | ImportQuantity || Integer || Returns the number of items, the Chute Outlet is holding, in grams. | ||
+ | |- | ||
+ | | ImportSlotOccupant || Boolean || Returns whether the Chute Outlet is holding an item. (0 for no, 1 for yes) | ||
+ | |} | ||
+ | |||
+ | === Chute Inlet === | ||
+ | |||
+ | ==== Data Parameters ==== | ||
+ | This device does not have any logic parameters and can not be selected with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]]. | ||
+ | |||
+ | ==== Data Outputs ==== | ||
+ | These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]]. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them. | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! Output Name !! Data Type !! Description | ||
+ | |- | ||
+ | | ImportQuantity || Integer || Returns the number of items, the Chute Inlet is holding, in grams. | ||
+ | |- | ||
+ | | ImportSlotOccupant || Boolean || Returns whether the Chute Inlet is holding an item. (0 for no, 1 for yes) | ||
+ | |} |
Revision as of 01:07, 20 April 2018
Properties | |
---|---|
Stacks | Yes (10) |
Recipe | |
Created With | Autolathe, Fabricator, Hydraulic Pipe Bender |
Cost | 1g Iron* |
Construction | |
---|---|
Placed with | {{{placed_with_item}}} |
Placed on | {{{placed_on_grid}}} |
Contents
Description
Used to transport items. The Kit can be used to create 7 different variants, some of them are able to connect to power and logic network.
Recipes
Manufactory | Materials | Time | Energy |
---|---|---|---|
Autolathe | 3g Iron | 5 | 500 |
Fabricator | 1g Iron | 1 | 500 |
Hydraulic Pipe Bender | 1g Iron | 5 | 500 |
Recycler | 1,5g Iron | 5 | 1000 |
Data Network Properties
These are all Data Network properties of this devices.
Chute Bin
Data Parameters
These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Chute Bin, when set to 1. Closes it, when set to 0. |
On | Boolean | Turns the Chute Bin on when set to 1. Turns it off, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Chute Bin is turned on and receives power. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Chute Bin is open. (0 for no, 1 for yes) |
Error | Boolean | Returns whether the Chute Bin is flashing an error. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Chute Bin is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power, required by the Chute Bin, in watts. |
Chute Outlet
Data Parameters
These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Chute Outlet when set to 1. |
Lock | Boolean | Locks the Chute Outlet when set to 1. Unlocks it, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Open | Boolean | Returns whether the Chute Outlet is open. (0 for no, 1 for yes) This only returns 1 briefly, when the Chute Outlet opens. |
Lock | Boolean | Returns whether the Chute Outlet is locked. (0 for no, 1 for yes) |
ImportQuantity | Integer | Returns the number of items, the Chute Outlet is holding, in grams. |
ImportSlotOccupant | Boolean | Returns whether the Chute Outlet is holding an item. (0 for no, 1 for yes) |
Chute Inlet
Data Parameters
This device does not have any logic parameters and can not be selected with a Logic Writer or a Batch Writer.
Data Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
ImportQuantity | Integer | Returns the number of items, the Chute Inlet is holding, in grams. |
ImportSlotOccupant | Boolean | Returns whether the Chute Inlet is holding an item. (0 for no, 1 for yes) |