Actions

Difference between revisions of "Composite Door"

From Unofficial Stationeers Wiki

m (Better explanation)
m (Correction)
Line 102: Line 102:
 
| Lock || Boolean || Returns whether the lock on the door is active.
 
| Lock || Boolean || Returns whether the lock on the door is active.
 
|-
 
|-
| Setting || Boolean || Returns desired state of the door. (0 for close, 1 for open)
+
| Setting || Boolean || Returns desired state of the door. (0 for close, 1 for open) When Mode = 1
 
|-
 
|-
 
| Mode || Integer || 0 = Manual Control, 1 = Logic Control.
 
| Mode || Integer || 0 = Manual Control, 1 = Logic Control.

Revision as of 19:39, 29 August 2021


Composite Door
Recipe
Created With Autolathe, Fabricator
Cost 7g Iron, 3g Copper
Composite Door
Operation
Power Usage 10W
Construction
Placed with Kit (Door)
Placed on Large Grid
Stage 1
Deconstruction
Deconstructed with Crowbar

Purpose

A Composite Door is one type of door created using the Kit_(Door).

Characteristics

Tips

  • A Crowbar can be used to force the door open, as long as it is not Locked.

User Interface

An <ITEM> has no user interface. An <ITEM> provides the following user interface:

Name Type Function
<Name> <Type> <Function>

Settings

An <ITEM> has no settings. An <ITEM> will have the following settings:

Name Description
<Name> <Description>

Construction

Deconstruction

The following tools must be used in order to deconstruct the Door:

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
On Boolean Turns the Door on when set to 1. Turns it off when set to 0.
Open Boolean Opens the Door when set to 1. Closes it when set to 0.
Lock Boolean Locks the Door when set to 1. Unlocks it when set to 0.
Setting Boolean No Function.
Mode Integer 0 = Manual Control, 1 = Logic Control.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Door is turned on and receives power. (0 for no, 1 for yes)
On Boolean Returns whether the Door is turned on. (0 for no, 1 for yes)
Open Boolean Returns whether the Door is currently open.
Lock Boolean Returns whether the lock on the door is active.
Setting Boolean Returns desired state of the door. (0 for close, 1 for open) When Mode = 1
Mode Integer 0 = Manual Control, 1 = Logic Control.
RequiredPower Integer Returns the current amount of power required by the Door, in watts.

See Also

  • [[Guide (<Subject>)]]
  • [[<Related Kits or Items>)]]