Difference between revisions of "Glass Door"
From Unofficial Stationeers Wiki
(Added note about width being wider than composite doors) |
m |
||
Line 23: | Line 23: | ||
* They can be opened and closed from the panel, or from a [[Console]] equipped with [[Circuitboard (Door Control)]]. | * They can be opened and closed from the panel, or from a [[Console]] equipped with [[Circuitboard (Door Control)]]. | ||
* They are airtight (when closed), and can withstand around 200kPa pressure, which is lower than [[Composite Doors]], which can withstand around 300kPa. <ref>[https://docs.google.com/spreadsheets/d/1QF-nbW7fUMBaZzKwUp9smkQxVwfxMicF7FhgRFf7-Tw/edit#gid=1718464320 Cheat Sheet]</ref> | * They are airtight (when closed), and can withstand around 200kPa pressure, which is lower than [[Composite Doors]], which can withstand around 300kPa. <ref>[https://docs.google.com/spreadsheets/d/1QF-nbW7fUMBaZzKwUp9smkQxVwfxMicF7FhgRFf7-Tw/edit#gid=1718464320 Cheat Sheet]</ref> | ||
− | * They are, however, wider than composite doors so it's easier to get bulkier items like a [[Portable Tank]], [[Portable Air Scrubber]], or [[Portable Air Conditioner]] | + | * They are, however, wider than composite doors so it's easier to get bulkier items like a [[Portable Tank]], [[Portable Air Scrubber]], or [[Portable Air Conditioner]] unit through them. |
{{Data Network Header}} | {{Data Network Header}} |
Revision as of 22:48, 14 February 2021
Properties | |
---|---|
Stacks | No |
Operation | |
---|---|
Power Usage | 10W |
Burst Pressure | 200 kPa |
Construction | |
Placed with | Kit (Door) |
Placed on | Large Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Door) |
Contents
Description
The Glass Doors are created by using building with a Kit (Door).
- They can be opened and closed from the panel, or from a Console equipped with Circuitboard (Door Control).
- They are airtight (when closed), and can withstand around 200kPa pressure, which is lower than Composite Doors, which can withstand around 300kPa. [1]
- They are, however, wider than composite doors so it's easier to get bulkier items like a Portable Tank, Portable Air Scrubber, or Portable Air Conditioner unit through them.
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Glass Door, when set >= 1. Closes it, when set to < 1. |
Lock | Boolean | Locks the Glass Door, when set >= 1. Unlocks it, when set to <1. |
On | Boolean | Turns the Glass Door on, when set >= 1. Turns it off, when set to <1. |
Mode | Boolean | When <1 console on the door opens/closes door. When >= 1 console sets/resets Setting but does not affect door. |
Setting | Boolean | Desired state, mostly usefull for Logic based control when Mode >= 1. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Glass Door is turned on and receives power. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Glass Door is open. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the Glass Door is locked. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Glass Door is turned on. (0 for no, 1 for yes) |
Mode | Boolean | Return mode, 0 for default, 1 for logic based control |
Setting | Boolean | Returns desired state of the door. (0 for close, 1 for open) |
RequiredPower | Integer | Returns the current amount of power, required by the Glass Door, in watts. |