Glass Door
From Unofficial Stationeers Wiki
Properties | |
---|---|
Stacks | No |
Operation | |
---|---|
Power Usage | 10W |
Burst Pressure | 200 kPa |
Construction | |
Placed with | Kit (Door) |
Placed on | Large Grid |
Stage 1 | |
Next Stage Construction | |
Constructed with tool | Welding Torch |
Constructed with item | Plastic Sheet |
Deconstruction | |
Deconstructed with | Wrench |
Item received | Kit (Door) |
Stage 2 | |
Next Stage Construction | |
Constructed with tool | Crowbar |
Constructed with item | 2x Glass Sheets |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Plastic Sheet |
Stage 3 | |
Deconstruction | |
Deconstructed with | Angle Grinder |
Item received | 2x Glass Sheets |
Contents
Description[edit]
The Glass Doors are created by using building with a Kit (Door).
- They can be opened and closed from the panel, or from a Console equipped with Circuitboard (Door Control).
- They are airtight (when closed), and can withstand around 200kPa pressure, which is lower than Composite Doors, which can withstand around 300kPa. [1]
- They are, however, wider than composite doors so it's easier to get bulkier items like a Portable Tank, Portable Air Scrubber, or Portable Air Conditioner unit through them.
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Glass Door, when set >= 1. Closes it, when set to < 1. |
Lock | Boolean | Locks the Glass Door, when set >= 1. Unlocks it, when set to <1. |
On | Boolean | Turns the Glass Door on, when set >= 1. Turns it off, when set to <1. |
Mode | Boolean | When <1 console on the door opens/closes door. When >= 1 console sets/resets Setting but does not affect door. |
Setting | Boolean | Desired state, mostly usefull for Logic based control when Mode >= 1. |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Glass Door is turned on and receives power. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Glass Door is open. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the Glass Door is locked. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Glass Door is turned on. (0 for no, 1 for yes) |
Mode | Boolean | Return mode, 0 for default, 1 for logic based control |
Setting | Boolean | Returns desired state of the door. (0 for close, 1 for open) When Mode = 1 |
RequiredPower | Integer | Returns the current amount of power, required by the Glass Door, in watts. |