Actions

Difference between revisions of "Filter"

From Unofficial Stationeers Wiki

(Corrected seemingly half finished sentence about filters costing the same regardless of type in the same size category.)
(Tips: Zrillians breathe volatiles, not hydrogen (which isn't a thing currently, and isn't what volatiles are even once it becomes a thing, according to patch notes))
 
(5 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 
<languages />
 
<languages />
 
<translate>
 
<translate>
[[Category:Atmospherics]]
+
[[Category:Atmospherics]][[Category:Gas]]
 
{{Itembox
 
{{Itembox
 
  | name        = Filter (''gas'')
 
  | name        = Filter (''gas'')
Line 30: Line 30:
 
== Filter Size ==
 
== Filter Size ==
  
* Small filter lasts 2 hours.
+
* Small filter lasts 2 hours. <!-- 144 ticks per 1% -->
* Medium filter lasts 10 hours.
+
* Medium filter lasts 10 hours. <!-- 720 ticks per 1% -->
* Large filter lasts 20 hours.
+
* Large filter lasts 40 hours. <!-- 2880 ticks per 1% -->
 +
* Catalytic Filter lasts an unlimited amount of time, but are only available in creative mode.
 +
* The duration is counted as the number of ticks the filter is being used, and only counts ticks in which the filter removed the targeted gas from the input volume.  If none of the target gas is present in the input volume, the filter will not count as being used and will not degrade.
  
 
== Filter Types ==
 
== Filter Types ==
Line 41: Line 43:
 
* [[Pollutant]]
 
* [[Pollutant]]
 
* [[Volatiles]]
 
* [[Volatiles]]
 +
* [[Water]]
  
 
== Tips ==
 
== Tips ==
Line 46: Line 49:
 
# Players start the game with three filters, three [[Carbon Dioxide|CO2]] filters in the suit.
 
# Players start the game with three filters, three [[Carbon Dioxide|CO2]] filters in the suit.
 
# Players breathe out [[Carbon Dioxide|CO2]] (just like in real life) and this may need to be considered when setting up a pressurized atmosphere where a helmet will not be worn.
 
# Players breathe out [[Carbon Dioxide|CO2]] (just like in real life) and this may need to be considered when setting up a pressurized atmosphere where a helmet will not be worn.
 +
## Note that unlike real life, where concentrations of CO2 as low as 7-10% can cause asphyxiation, CO2 in Stationeers is entirely safe.  Players can comfortably breathe even very large ratios of CO2, as long as sufficient partial pressure of oxygen (specifically, 16 kPa) is also present.
 
# [[Arc Furnace|Arc Furnaces]] and [[Furnace|Furnaces]] produce waste products like pollutants or [[Carbon Dioxide|CO2]] which will need to be scrubbed out of a pressurized base (assuming the [[Furnace]] is not already hooked up to a [[Pipe]] system)
 
# [[Arc Furnace|Arc Furnaces]] and [[Furnace|Furnaces]] produce waste products like pollutants or [[Carbon Dioxide|CO2]] which will need to be scrubbed out of a pressurized base (assuming the [[Furnace]] is not already hooked up to a [[Pipe]] system)
# If you're choosing to play as a [[Zrilian]] you will instead have 3 [[Nitrous Oxide]] filters instead of 3 [[Carbon Dioxide|CO2]] filters as they breath in [[hydrogen]] and exhale [[Nitrous Oxide]] instead of [[Carbon Dioxide|CO2]].
+
# If you're choosing to play as a [[Zrilian]] you will instead have 3 [[Nitrous Oxide]] filters instead of 3 [[Carbon Dioxide|CO2]] filters as they breath in [[Volatiles]] and exhale [[Nitrous Oxide]] instead of [[Carbon Dioxide|CO2]].
  
 
== Variants ==
 
== Variants ==

Latest revision as of 04:21, 18 June 2024


Filter (gas)
ItemGasFilterOxygen.png
Properties
Stacks no
Recipe
Created With Hydraulic Pipe Bender
Cost 5g Iron


Medium Filter (gas)
ItemGasFilterOxygenM.png
Properties
Stacks no
Recipe
Created With Hydraulic Pipe Bender
Cost 5g Iron, 5g Silver, 1g Constantan


Heavy Filter (gas)
ItemGasFilterOxygenL.png
Properties
Stacks no
Recipe
Created With Hydraulic Pipe Bender
Cost 5g Steel, 1g Invar, 1g Stellite


Filters are used to filter out gas from an input. Only gasses matching the filters type will pass through it.

All filters of the same size cost the same regardless of type and can be made in the Hydraulic Pipe Bender.

Filter Size[edit]

  • Small filter lasts 2 hours.
  • Medium filter lasts 10 hours.
  • Large filter lasts 40 hours.
  • Catalytic Filter lasts an unlimited amount of time, but are only available in creative mode.
  • The duration is counted as the number of ticks the filter is being used, and only counts ticks in which the filter removed the targeted gas from the input volume. If none of the target gas is present in the input volume, the filter will not count as being used and will not degrade.

Filter Types[edit]

Tips[edit]

  1. Players start the game with three filters, three CO2 filters in the suit.
  2. Players breathe out CO2 (just like in real life) and this may need to be considered when setting up a pressurized atmosphere where a helmet will not be worn.
    1. Note that unlike real life, where concentrations of CO2 as low as 7-10% can cause asphyxiation, CO2 in Stationeers is entirely safe. Players can comfortably breathe even very large ratios of CO2, as long as sufficient partial pressure of oxygen (specifically, 16 kPa) is also present.
  3. Arc Furnaces and Furnaces produce waste products like pollutants or CO2 which will need to be scrubbed out of a pressurized base (assuming the Furnace is not already hooked up to a Pipe system)
  4. If you're choosing to play as a Zrilian you will instead have 3 Nitrous Oxide filters instead of 3 CO2 filters as they breath in Volatiles and exhale Nitrous Oxide instead of CO2.

Variants[edit]