Elevator
From Unofficial Stationeers Wiki
(Redirected from Kit (Elevator) Elevator Shaft)
Constructing Options | Elevator Shaft, Elevator Level |
---|---|
Properties | |
Stacks | Yes (5) |
Recipe | |
Created With | Electronics Printer, Fabricator |
Cost | 2g Copper, 4g Gold, 2g Steel, 2g Solder |
Contents
Description[edit]
The elevator allows easy travel to other floors.
Use[edit]
Elevators allow easy access to other floors. They operate using two placement types: elevator level for floors where the elevator stops, and elevator shaft for those where they don't.
Logic and enumeration are automatically applied, and the elevator car is created when building a level.
All levels and shafts must face the same direction, so that their spines align..
Warning: All elevator-placements need to be connected. Otherwise it seems like one elevator but in reality you build several stacked and won't be able to travel from level to level.
Elevator Shaft[edit]
Operation | |
---|---|
Power Usage | 5W |
Construction | |
Placed with | Kit (Elevator) |
Placed on | Large Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Elevator) |
The shaft section to build on floors it should not open like floor frames etc.
Currently does not require power.
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
On | Boolean | Turns the device on, when set >= 1. Turns it off, when set to <1. |
ElevatorSpeed | Integer | Sets the desired speed of the elevator. (0.5 - 20) |
ElevatorLevel | Integer | When written to, makes the carriage go to that level. |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the device is turned on and receives power. (0 for no, 1 for yes) |
On | Boolean | Returns whether the device is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power, required by the device, in watts. |
ElevatorSpeed | Integer | Returns the current speed setting. (0.5 - 20) |
ElevatorLevel | Integer | Returns current level carriage is on |
Elevator Level[edit]
Operation | |
---|---|
Power Usage | 5W |
Construction | |
Placed with | Kit (Elevator) |
Placed on | Large Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Elevator) |
The elevator level provides an entrance/exit stop for the elevator car.
Requires power to open the door automatically and use the call button
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the device , when set >= 1. Closes it, when set to < 1. |
Lock | Boolean | Locks the device , when set >= 1. Unlocks it, when set to <1. |
On | Boolean | Turns the device on, when set >= 1. Turns it off, when set to <1. |
ElevatorSpeed | Integer | Sets the desired speed of the elevator. (0.5 - 20) |
Elevatorlevel | Integer | When written to, makes the carriage go to that level. |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the device is turned on and receives power. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the device is open. (0 for no, 1 for yes) |
Error | Boolean | Returns whether the device is flashing an error. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the device is locked. (0 for no, 1 for yes) |
On | Boolean | Returns whether the device is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power, required by the Glass Door, in watts. |
ElevatorSpeed | Integer | Returns the current speed setting. (0.5 - 20) |
ElevatorLevel | Integer | Returns current level carriage is on |