Actions

Difference between revisions of "Circuitboard (Advanced Airlock)"

From Unofficial Stationeers Wiki

m (Add substitution option)
m (Refinements after in-game testing)
Line 3: Line 3:
 
<translate>
 
<translate>
 
{{Itembox
 
{{Itembox
  | image      =  
+
  | image      = [[File:Circuitboard_door_control.jpg]]
 
  | name        = Circuitboard (Advanced Airlock)
 
  | name        = Circuitboard (Advanced Airlock)
 
  | createdwith = [[Electronics Printer]], [[Fabricator]]
 
  | createdwith = [[Electronics Printer]], [[Fabricator]]
Line 12: Line 12:
 
}}
 
}}
 
==Description==
 
==Description==
A Circuitboard (Advanced Airlock) can be used to automate the operation of an airlock separating two pressurized atmospheres.  
+
A Circuitboard (Advanced Airlock) can be used to automate the operation of an airlock separating two pressurized atmospheres. [[Guide (Airlock) Atmosphere to Atmosphere]] provides additional information regarding the function, construction, and operation of airlock using a Circuitboard (Advanced Airlock).
  
For a detailed guide to the function, construction, and operation of airlock using a Circuitboard (Advanced Airlock), please refer to [[Guide (Airlock) Atmosphere to Atmosphere]].
+
A [[Circuitboard (Airlock)]] might serve as a suitable substitution, being a simpler system to construct but lacking support for more than one pressurized atmosphere and [[Console Slave]]s.  
  
A [[Circuitboard (Airlock)]] might serve as a suitable substitution, be a more simple system to construct but lacking support for two pressurized atmospheres and [[Guide (Airlock) Atmosphere to Atmosphere#Console Slaves|Console Slaves]].  
+
==Characteristics==
 +
* Its settings will refer to the two adjoining environments as either "interior" or "exterior".
 +
* Its pressurization phase will stall if there is not enough gas available to the selected interior or exterior [[Active Vent]] to reach the set "External #Pa" or "Internal #Pa".
 +
* Its depressurization phase will stall if a complete vacuum cannot be achieved within the [[Large Grid]] volumes in which all selected [[Gas Sensor]]s reside.
 +
* If its settings for "External #Pa" or "Internal #Pa" are set to 0, the corresponding pressurization phase will be skipped.
 +
* When powered, all selected [[Portals]] and Active Vents will be locked, preventing their manual use even when power is subsequently denied.
 +
* Supports only one "interior" and one "exterior" [[Active Vent]]
 +
* Supports multiple [[Gas Sensor]]s
 +
* Supports additional [[Console Slave]]s
 +
 
 +
==Console Slave==
 +
Additional control [[Console]]s are useful when airlocks become large or remote control is desired. A Circuitboard (Advanced Airlock) can support one or more additional enslaved consoles. All Console Slaves will mirror the action and state of the console that enslaved them. Only one "master" console can enslave other Circuitboard (Advanced Airlock) equipped consoles residing on the same [[Wire Network]].  
  
 
==User Interface==
 
==User Interface==
A Circuitboard (Advanced Airlock) equipped and powered [[Console]] will display the following user interfaces:
+
A powered [[Console]] equipped with a Circuitboard (Advanced Airlock) and will display the following user interface:
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
 
! Name || Type !! Function
 
! Name || Type !! Function
 
|-
 
|-
| Cancel Depressurize || On-screen button ||  
+
| Cancel Depressurize || Console button || Cancel depressurization and proceed to repressurization (Warning: Atmospheric mixing may occur)
 
|-
 
|-
| Cancel Pressurize || On-screen button ||  
+
| Cancel Pressurize || Console button || Cancel pressurization and opens door
 
|-
 
|-
| Emergency Override || On-screen button ||  
+
| Emergency Override || Console button || Unused
 
|-
 
|-
| Cycle to Exterior|| On-screen button ||  
+
| Cycle to Exterior || Console button || Begin airlock operations to allow access to Exterior environment
 
|-
 
|-
| Cycle to Interior|| On-screen button ||  
+
| Cycle to Interior || Console button || Begin airlock operations to allow access to Interior environment
 
|-
 
|-
 
|}
 
|}
  
==Characteristics==
+
==Settings==
 +
A powered [[Console]] equipped with a Circuitboard (Advanced Airlock) and will display the following user interface:
 +
{| class="wikitable"
 +
|-
 +
! Name || Description
 +
|-
 +
| External #Pa || Set minimum internal airlock pressure to open exterior portal
 +
|-
 +
| Internal #Pa || Set minimum internal airlock pressure to open interior portal
 +
|-
 +
| «[[Portal]]» EXTERNAL || Designates one portal to exterior environment
 +
|-
 +
| «Portal» INTERNAL || Designates one portal to interior environment
 +
|-
 +
| «[[Active Vent]]» EXTERNAL || Designates one Active Vent for exterior atmosphere
 +
|-
 +
| «Active Vent» INTERNAL || Designates one Active Vent for interior atmosphere
 +
|-
 +
| «[[Gas Sensor]]» SENSOR || Designates one or more Gas Sensors for airlock pressure measurements
 +
|-
 +
| «[[Light]]» LIGHT || Designates one or more Lights to be activated only during airlock operation
 +
|-
 +
| «[[Console]]» MAKE SLAVE || Designates one or more [[Console Slaves]]
 +
|-
 +
|}
  
 
==Manufacture==
 
==Manufacture==
Line 54: Line 89:
  
 
==Destruction==
 
==Destruction==
Circuitboard (Advanced Airlock)'s can be destroyed using a [[Arc Furnace]], a [[Furnace]] or with ?? shots from a [[Weapons|weapon]]
+
Circuitboard (Advanced Airlock)'s can be destroyed using a [[Arc Furnace]], a [[Furnace]] or with ## shots from a [[Weapons|weapon]]
  
 
==See Also==
 
==See Also==

Revision as of 02:54, 20 March 2019


Circuitboard (Advanced Airlock)
Circuitboard door control.jpg
Stacks No
Paintable No
Recipe
Created With Electronics Printer, Fabricator

Description

A Circuitboard (Advanced Airlock) can be used to automate the operation of an airlock separating two pressurized atmospheres. Guide (Airlock) Atmosphere to Atmosphere provides additional information regarding the function, construction, and operation of airlock using a Circuitboard (Advanced Airlock).

A Circuitboard (Airlock) might serve as a suitable substitution, being a simpler system to construct but lacking support for more than one pressurized atmosphere and Console Slaves.

Characteristics

  • Its settings will refer to the two adjoining environments as either "interior" or "exterior".
  • Its pressurization phase will stall if there is not enough gas available to the selected interior or exterior Active Vent to reach the set "External #Pa" or "Internal #Pa".
  • Its depressurization phase will stall if a complete vacuum cannot be achieved within the Large Grid volumes in which all selected Gas Sensors reside.
  • If its settings for "External #Pa" or "Internal #Pa" are set to 0, the corresponding pressurization phase will be skipped.
  • When powered, all selected Portals and Active Vents will be locked, preventing their manual use even when power is subsequently denied.
  • Supports only one "interior" and one "exterior" Active Vent
  • Supports multiple Gas Sensors
  • Supports additional Console Slaves

Console Slave

Additional control Consoles are useful when airlocks become large or remote control is desired. A Circuitboard (Advanced Airlock) can support one or more additional enslaved consoles. All Console Slaves will mirror the action and state of the console that enslaved them. Only one "master" console can enslave other Circuitboard (Advanced Airlock) equipped consoles residing on the same Wire Network.

User Interface

A powered Console equipped with a Circuitboard (Advanced Airlock) and will display the following user interface:

Name Type Function
Cancel Depressurize Console button Cancel depressurization and proceed to repressurization (Warning: Atmospheric mixing may occur)
Cancel Pressurize Console button Cancel pressurization and opens door
Emergency Override Console button Unused
Cycle to Exterior Console button Begin airlock operations to allow access to Exterior environment
Cycle to Interior Console button Begin airlock operations to allow access to Interior environment

Settings

A powered Console equipped with a Circuitboard (Advanced Airlock) and will display the following user interface:

Name Description
External #Pa Set minimum internal airlock pressure to open exterior portal
Internal #Pa Set minimum internal airlock pressure to open interior portal
«Portal» EXTERNAL Designates one portal to exterior environment
«Portal» INTERNAL Designates one portal to interior environment
«Active Vent» EXTERNAL Designates one Active Vent for exterior atmosphere
«Active Vent» INTERNAL Designates one Active Vent for interior atmosphere
«Gas Sensor» SENSOR Designates one or more Gas Sensors for airlock pressure measurements
«Light» LIGHT Designates one or more Lights to be activated only during airlock operation
«Console» MAKE SLAVE Designates one or more Console Slaves

Manufacture

Circuitboard (Advanced Airlock)'s are manufactured using:

Manufacturer Requirements
Electronics Printer ###J Energy, 1g Iron, 5g Gold, 5g Copper
Fabricator ###J Energy, 1g Iron, 5g Gold, 5g Copper

Recycling

Circuitboard (Advanced Airlock)'s can be recycled using a Recycler in conjunction with a Centrifuge to yield ##g Iron, ##g Gold, and ##g Copper

Destruction

Circuitboard (Advanced Airlock)'s can be destroyed using a Arc Furnace, a Furnace or with ## shots from a weapon

See Also