Kit (Atmospherics)
ItemKitAtmospherics.png
Stacks False
Recipe
Created With Hydraulic Pipe Bender, Fabricator
Cost 10g Iron, 5g Gold, 20g Copper


Description

This kit produces the following:

Air Conditioner Unit

Air Conditioner
Atmospherics front.jpg
Operation
Power Usage Up to 7000W based on temperature difference
Construction
Placed with Kit (Atmospherics)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Atmospherics)

Description

Used to lower or raise the temperature of Gas in a pipe network. It has a range of -200 through 200 Celsius for the temperature output.

Usage

Once you have placed the Air Conditioner Unit in your desired location, there are 3 separate connections that will need to be made:

  1. Input - The starting gas that is desired to be cooled or heated
  2. Output - The exhausted gas after energy has been transferred to or from the Coolant in the waste pipe network
  3. Waste - Connection where energy is transferred to the Coolant in the pipe network


Waste Pipe Network
A connected gas pipe network containing any desired Coolant. The Air Conditioner Unit will draw or expel heat from/to the coolant to adjust the input gas temperature to match the selected output temperature.

If the waste pipe network is below 100kPa pressure upon starting the Air Conditioning Unit, it will divert inputted gas from the output port to the waste port until the minimum 100kPa pressure threshold is met within the waste pipe network.

Example A/C Setup

Cooling

Attached to the waste pipe network should be either Pipe Radiators or Medium Radiators to convect heat in a pressurized environment or radiate heat in a vacuum environment. Make the pipe network loop on back to the waste port after the radiators for slightly better efficiency.

Heating

Ensuring the temperature of the coolant is higher than the temperature of the gas you want attempting to heat will allow the Air Conditioner Unit to heat the gas being run through the input port. Attaching a Pipe Heater is a quick method of raising the temperature of the Coolant in the waste pipe network.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description
Open Boolean Starts the Air Conditioner Unit, when set to 1. Stops it, when set to 0. (This seems to work only with Batch Writer and not with Logic Writer - tested on game ver: v0.1.1362.6552).
Mode Integer (Unknown) (Judging by the "Mode" output, it accepts values in the range 0-2.)
Lock Boolean Locks the Air Conditioner Unit, when set to 1. Unlocks it, when set to 0.
On Boolean Turns the Air Conditioner Unit on, when set to 1. Turns it off, when set to 0.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Air Conditioner Unit is turned on and receives power. (0 for no, 1 for yes)
Open Boolean Returns whether the Air Conditioner Unit is running. (0 for no, 1 for yes)
Mode Integer (Unknown) (Returns output in the range 0-2, equivalent to the input of the "Mode" parameter.)
Error Boolean Returns whether the Air Conditioner Unit is flashing an error. (0 for no, 1 for yes)
Lock Boolean Returns whether the Air Conditioner Unit is locked. (0 for no, 1 for yes)
On Boolean Returns whether the Air Conditioner Unit is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current amount of power, required by the Air Conditioner, in Watts.

Filtration

Filtration
Filtration.jpg
Operation
Power Usage 10W
Construction
Placed with Kit (Atmospherics)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Atmospherics)

Description

Used to separate gasses from one pipe network into another using filters. Can filter up to two (2) gases at once.

Usage

Place the Kit (Atmospherics) and change the variant to Filtration.
Place filters in the machine for what you want to filter out.
There are three filtration pipe connections.
Filtration Input is where you connect the incoming atmosphere to be passed through the Filtration Atmospherics.
Filtration Unfiltered is the remaining mix after extracting whatever the filters did.
Filtration Filtered is the filtered material for which you placed filters in the machine for.

Be aware that the filtration unit unrealistically has an infinitely powerful pump integrated into its output port. That means as long as it is turned on and there is gas to filter out from the input it will pump that filtered out gas into the output pipe network (no matter how high the pressure in that output pipe network already is!). So eventually that pipe network will burst (around 60 MPa) unless you provide some sort of pop-off valve (e.g. a combination of a back-pressure regulator and a passive vent) or use a pipe analyzer and some logic to turn the filtration unit off when a certain amount of pressure is exceeded in the output pipe network. The filtration system can handle an input gas flow of just over 2.3L from a volume pump.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description
On Boolean Turns the Filtration Unit on, when set to 1. Turns it off, when set to 0.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Logic

Output Name Data Type Description
Power Boolean Returns whether the Filtration Unit is turned on and receives power. (0 for no, 1 for yes)
Error Boolean Returns whether the Filtration Unit is flashing an error. (0 for no, 1 for yes)
Lock Boolean Returns whether the Filtration Unit is locked. (0 for no, 1 for yes)
Maximum
Mode Integer 0=Idle, 1=Active
On Boolean Returns whether the Filtration Unit is turned on. (0 for no, 1 for yes)
Open Boolean Returns whether the Filtration Unit is flashing an error. (0 for no, 1 for yes)
OperationalTemperatureEfficiency
RequiredPower Integer Returns the current amount of power, required by the Filtration Unit, in Watts.
PrefabHash Integer The Hash of the structure.
PressureEfficiency Float
CombustionInput
CombustionOutput
CombustionOutput2
PressureInput Float the pressure on the input pipe
PressureOutput Float the pressure on the filtered output pipe
PressureOutput2 Float the pressure on the waste output pipe
Ratio Float
RatioCarbonDioxideInput
RatioCarbonDioxideOutput
RatioCarbonDioxideOutput2
RatioNitrogenInput
RatioNitrogenOutput
RatioNitrogenOutput2
RatioNitrousOxideInput
RatioNitrousOxideOutput
RatioNitrousOxideOutput2
RatioOxygenInput
RatioOxygenOutput
RatioOxygenOutput2
RatioPollutantInput
RatioPollutantOutput
RatioPollutantOutput2
RatioVolatilesInput
RatioVolatilesOuput
RatioVolatilesOuput2
RatioWaterInput
RatioWaterOutput
RatioWaterOutput2
Setting
TemperatureDifferencialEfficiency Float a value from 0..1.0 indicating the efficiency based on the temperature differential between the "waste" output and the conditioned air stream. This is not updated while the unit is Idle.
TemperatureInput
TemeratureOutput
TemeratureOutput2
TotalMolesInput
TotalMolesOutput
TotalMolesOutput2

Logic Slots

Slot 0 and 1 are the two gas filters. Slot 2 is the programmable chip

Output Name Data Type Description
Occupied Boolean Returns whether the slot is occupied. (0 for no, 1 for yes)
OccupantHash Integer Returns the hash of the object in the slot.
Quantity Integer Returns the current quantity, such as stack size, of the item in the slot.
Damage Integer Returns the damage state of the item in the slot.
Class Integer Returns an integer representing the class of object.
MaxQuanity Integer Returns max stack size of the item in the slot.
PrefabHash Integer Returns the hash of the structure in the slot.

Electrolyzer

Electrolyzer
Electrolyzer front.png
Operation
Power Usage 1200W
Construction
Placed with Kit (Atmospherics)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Atmospherics)

Description

Used to separate water (H2O) into H2 and O2 in a 2 to 1 ratio (perfect fuel).

Usage

Place the Kit (Atmospherics) and change the variant to Electrolyzer.
There are two pipe connections.
Electrolyzer Input is where you connect the incoming water.
Electrolyzer Output is where the H2 and O2 comes out mixed together.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Parameter Name Data Type Description
Lock Boolean Locks the Electrolyzer , when set to 1. Unlocks it, when set to 0.
On Boolean Turns the Electrolyzer on, when set to 1. Turns it off, when set to 0.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the Electrolyzer is turned on and receives power. (0 for no, 1 for yes)
Error Boolean Returns whether the Electrolyzer is flashing an error. (0 for no, 1 for yes)
Lock Boolean Returns whether the Electrolyzer is locked. (0 for no, 1 for yes)
On Boolean Returns whether the Electrolyzer is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current amount of power, required by the Electrolyzer, in Watts.

Hydrogen Combustor

The hydrogen combustor takes a fuel mix (H2+O2), and generates water, a *lot* of heat, and waste gasses.

Limiting inflow is *highly* recommended, due to the massive amounts of heat generated.