Actions

Difference between revisions of "Atmospheric Components Quick Reference"

From Unofficial Stationeers Wiki

(Split large and small tank. Improve phrasing of functions.)
(Add clamp-on components.)
Line 6: Line 6:
 
|-
 
|-
 
| [[Pipes|Pipe]] (various shapes) || [[Pipes|Kit (Pipe)]] || colspan="2"|2-6 generic || No || No || No || - || Provide a pathway.
 
| [[Pipes|Pipe]] (various shapes) || [[Pipes|Kit (Pipe)]] || colspan="2"|2-6 generic || No || No || No || - || Provide a pathway.
 +
|-
 +
| [[Pipe Label]] || [[Pipe Label|Kit (Pipe Label)]] || colspan="2"|clamp-on || - || - || - || - || Visually label pipes.
 
|-
 
|-
 
| [[Pipe Valve]] || [[Pipe Valve|Kit (Pipe Valve)]] || colspan="2"|2 generic || No || Manual only || No|| -|| Open/close flow manually.
 
| [[Pipe Valve]] || [[Pipe Valve|Kit (Pipe Valve)]] || colspan="2"|2 generic || No || Manual only || No|| -|| Open/close flow manually.
Line 16: Line 18:
 
|-
 
|-
 
| [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at input.
 
| [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at input.
 +
|-
 +
| [[Pipe Meter]] || [[Pipe Meter|Kit (Pipe Meter)]] || colspan="2"|clamp-on || - || - || - || - || Visually show pipe's pressure.
 +
|-
 +
| [[Pipe Analyzer]] || [[Pipe Analyzer|Kit (Pipe Analyzer)]] || colspan="2"|clamp-on || - || - || - || 50W || Sense pipe's pressure, temperature, and composition, for visual display and logic circuits.
 
|-
 
|-
 
| [[Pipe Gas Mixer]] || [[Pipe Gas Mixer|Kit (Gas Mixer)]] || 2 || 1 || Yes || Yes || Yes<sup>1</sup> || 100W || Mix fluids: Combine two input mixes into one output mix, at an adjustable ratio.
 
| [[Pipe Gas Mixer]] || [[Pipe Gas Mixer|Kit (Gas Mixer)]] || 2 || 1 || Yes || Yes || Yes<sup>1</sup> || 100W || Mix fluids: Combine two input mixes into one output mix, at an adjustable ratio.
Line 27: Line 33:
 
| [[Wall Cooler]] || [[Wall Cooler|Kit (Wall Cooler)]] || space || 1 || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || ? || Cool a space: Actively remove heat from a space into a pipe.
 
| [[Wall Cooler]] || [[Wall Cooler|Kit (Wall Cooler)]] || space || 1 || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || ? || Cool a space: Actively remove heat from a space into a pipe.
 
|-
 
|-
| [[Active Vent]] || [[Active Vent|Kit (Active Vent)]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe.
+
| [[Pipe Radiator]] || [[Pipe Radiator|Kit (Pipe Radiator)]] || colspan="2"|clamp-on || - || - || - || - || Cool fluid or heat space: Passively transfer heat from a pipe to a space.
 
|-
 
|-
| [[Passive Vent]] || [[Passive Vent|Kit (Passive Vent)]] || colspan="2"|1 pipe, 1 space || No || No || No || - || Equalize pressure between a space and a pipe.
+
| [[Active Vent]] || [[Active Vent|Kit (Active Vent)]] || colspan="2"|1 generic, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe.
 +
|-
 +
| [[Passive Vent]] || [[Passive Vent|Kit (Passive Vent)]] || colspan="2"|1 generic, 1 space || No || No || No || - || Equalize pressure between a space and a pipe.
 
|-
 
|-
 
| [[Gas Tank Storage]] || [[Gas Tank Storage|Kit (Canister Storage)]] || colspan="2"|1 generic || No || No || No || - || Small storage: Attach pipes to [[Gas Canister]]s (removable, inventory-portable fluid storage).
 
| [[Gas Tank Storage]] || [[Gas Tank Storage|Kit (Canister Storage)]] || colspan="2"|1 generic || No || No || No || - || Small storage: Attach pipes to [[Gas Canister]]s (removable, inventory-portable fluid storage).
Line 40: Line 48:
 
|}
 
|}
  
'''Kit''': The item used to build the component. All of these items are manufactured with a [[Hydraulic Pipe Bender]] or [[Fabricator]], except where noted.
+
'''Kit''': The item used to build the component. All of these items are manufactured with a [[Hydraulic Pipe Bender]] or [[Fabricator]].
 +
 
 +
'''Input/Output''': "Generic" connections are pipe fittings that are not explicitly for input or output. "Space" indicates an interface to fluids that are not contained in pipes (e.g., the atmosphere or the contents of a room). "Clamp-on" components have no fittings of their own; they clamp onto an existing Straight Pipe.
  
 
'''One-way''': Does the component prevent fluid from flowing the wrong way, from output to input?
 
'''One-way''': Does the component prevent fluid from flowing the wrong way, from output to input?

Revision as of 13:32, 26 May 2020

This is a quick reference to the various components of a piped-fluid network.

Component Kit Inputs Outputs One-way? Switched? Compressor? Max. Power Primary Function
Pipe (various shapes) Kit (Pipe) 2-6 generic No No No - Provide a pathway.
Pipe Label Kit (Pipe Label) clamp-on - - - - Visually label pipes.
Pipe Valve Kit (Pipe Valve) 2 generic No Manual only No - Open/close flow manually.
Pipe Digital Valve Kit (Digital Valve) 2 generic No Yes No 25W Open/close flow using logic circuits.
Pipe Volume Pump Kit (Volume Pump) 1 1 Yes Yes Yes 800W, varies Pump fluid at adjustable rate.
Pressure Regulator Kit (Pressure Regulator) 1 1 Yes Yes Yes 100W Achieve target pressure at output.
Back Pressure Regulator Kit (Pressure Regulator) 1 1 Yes Yes Yes 100W Achieve target pressure at input.
Pipe Meter Kit (Pipe Meter) clamp-on - - - - Visually show pipe's pressure.
Pipe Analyzer Kit (Pipe Analyzer) clamp-on - - - 50W Sense pipe's pressure, temperature, and composition, for visual display and logic circuits.
Pipe Gas Mixer Kit (Gas Mixer) 2 1 Yes Yes Yes1 100W Mix fluids: Combine two input mixes into one output mix, at an adjustable ratio.
Filtration Kit (Atmospherics) 1 2 Yes Yes Yes 5W Sort fluids: Separate an input mix into a pure output and a "leftover" output.
Electrolyzer Kit (Atmospherics) 1 1 Yes Yes Yes 1,400W Create fuel: From input H2O, output mixed O2 and Volatiles.
Air Conditioner Kit (Atmospherics) 1 2 Yes Yes Yes 7,000W, varies Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs.
Wall Cooler Kit (Wall Cooler) space 1 Yes, for heat2 Yes, for heat2 Yes, for heat2  ? Cool a space: Actively remove heat from a space into a pipe.
Pipe Radiator Kit (Pipe Radiator) clamp-on - - - - Cool fluid or heat space: Passively transfer heat from a pipe to a space.
Active Vent Kit (Active Vent) 1 generic, 1 space Yes, reversable Yes Yes 100W Pump pressure between a space and a pipe.
Passive Vent Kit (Passive Vent) 1 generic, 1 space No No No - Equalize pressure between a space and a pipe.
Gas Tank Storage Kit (Canister Storage) 1 generic No No No - Small storage: Attach pipes to Gas Canisters (removable, inventory-portable fluid storage).
Tank Connector Kit (Tank Connector) 1 generic No No No - Medium storage: Attach pipes to Portable Tanks (removable, luggable fluid storage), and also to Portable Air Scrubbers and Portable Air Conditioners.
Small Tank Kit (Tank) 1 generic No Logic only? No - Permanent, high-capacity fluid storage.
Large Tank Kit (Tank) × 5 1 generic No Logic only? No - Permanent, super-capacity fluid storage.

Kit: The item used to build the component. All of these items are manufactured with a Hydraulic Pipe Bender or Fabricator.

Input/Output: "Generic" connections are pipe fittings that are not explicitly for input or output. "Space" indicates an interface to fluids that are not contained in pipes (e.g., the atmosphere or the contents of a room). "Clamp-on" components have no fittings of their own; they clamp onto an existing Straight Pipe.

One-way: Does the component prevent fluid from flowing the wrong way, from output to input?

Switched: Does it prevent all flow when switched off or unpowered? Except where noted, switched components can be switched either manually or using logic circuits.

Compressor: Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output, or it does not enable any pressure changes.

Note 1: While the Pipe Gas Mixer will actively compress from output to input, it will stop when either input is empty, to preserve the mix ratio.

Note 2: The Wall Cooler's one-way, switched, and "compressor" qualities apply only to the heat exchange. It does not directly affect the pressure or flow in its attached pipe.