Actions

Difference between revisions of "Atmospheric Components Quick Reference"

From Unofficial Stationeers Wiki

(No compressor can mean no pressure changes.)
(Add storage components.)
Line 5: Line 5:
 
! Component !! Kit !! Inputs !! Outputs !! One-way? !! Switched? !! Compressor? !! Max. Power !! Primary Function
 
! Component !! Kit !! Inputs !! Outputs !! One-way? !! Switched? !! Compressor? !! Max. Power !! Primary Function
 
|-
 
|-
| [[Pipes|Pipe]] (various shapes) || [[Pipes]] || colspan="2"|2-6 generic || No || No || No || - || Provide a pathway.
+
| [[Pipes|Pipe]] (various shapes) || [[Pipes|Kit (Pipe)]] || colspan="2"|2-6 generic || No || No || No || - || Provide a pathway.
 
|-
 
|-
| [[Pipe Valve]] || [[Pipe Valve]] || colspan="2"|2 generic || No || Manual || No|| -|| Open/close flow manually.
+
| [[Pipe Valve]] || [[Pipe Valve|Kit (Pipe Valve)]] || colspan="2"|2 generic || No || Manual || No|| -|| Open/close flow manually.
 
|-
 
|-
| [[Pipe Digital Valve]] || [[Pipe Digital Valve]] || colspan="2"|2 generic || No || Yes || No || 25W || Open/close flow using [[Kit (Logic I/O)|logic circuits]].
+
| [[Pipe Digital Valve]] || [[Pipe Digital Valve|Kit (Digital Valve)]] || colspan="2"|2 generic || No || Yes || No || 25W || Open/close flow using [[Kit (Logic I/O)|logic circuits]].
 
|-
 
|-
| [[Pipe Volume Pump]] || [[Pipe Volume Pump]] || 1 || 1 || Yes || Yes || Yes || 800W, varies || Pump fluid at adjustable rate.
+
| [[Pipe Volume Pump]] || [[Pipe Volume Pump|Kit (Volume Pump)]] || 1 || 1 || Yes || Yes || Yes || 800W, varies || Pump fluid at adjustable rate.
 
|-
 
|-
| [[Pressure_Regulator#Pressure_Regulator|Pressure Regulator]] || [[Pressure Regulator]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at output.
+
| [[Pressure_Regulator#Pressure_Regulator|Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at output.
 
|-
 
|-
| [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || [[Pressure Regulator]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at input.
+
| [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || [[Pressure Regulator|Kit (Pressure Regulator)]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at input.
 
|-
 
|-
| [[Pipe Gas Mixer]] || [[Pipe Gas Mixer]] || 2 || 1 || Yes || Yes || Yes<sup>1</sup> || 100W || Combine two input mixes into one output mix, at an adjustable ratio.
+
| [[Pipe Gas Mixer]] || [[Pipe Gas Mixer|Kit (Gas Mixer)]] || 2 || 1 || Yes || Yes || Yes<sup>1</sup> || 100W || Combine two input mixes into one output mix, at an adjustable ratio.
 
|-
 
|-
 
| [[Kit (Atmospherics) Filtration|Filtration]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || 5W || Separate an input mix into a pure output and a "leftover" output.
 
| [[Kit (Atmospherics) Filtration|Filtration]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || 5W || Separate an input mix into a pure output and a "leftover" output.
Line 25: Line 25:
 
| [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || 7,000W, varies || Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs.
 
| [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || 7,000W, varies || Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs.
 
|-
 
|-
| [[Wall Cooler]] || [[Wall Cooler]] || space || 1 || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || ? || Actively remove heat from a space into a pipe.
+
| [[Wall Cooler]] || [[Wall Cooler|Kit (Wall Cooler)]] || space || 1 || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || Yes, for heat<sup>2</sup> || ? || Actively remove heat from a space into a pipe.
 
|-
 
|-
| [[Active Vent]] || [[Active Vent]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe.
+
| [[Active Vent]] || [[Active Vent|Kit (Active Vent)]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe.
 
|-
 
|-
| [[Passive Vent]] || [[Passive Vent]] || colspan="2"|1 pipe, 1 space || No || No || No || - || Equalize pressure between a space and a pipe.
+
| [[Passive Vent]] || [[Passive Vent|Kit (Passive Vent)]] || colspan="2"|1 pipe, 1 space || No || No || No || - || Equalize pressure between a space and a pipe.
 
|-
 
|-
| [[Gas Tank Storage]] || kit || x || x || 1w || switch || comp || 100W || function
+
| [[Gas Tank Storage]] || [[Gas Tank Storage|Kit (Canister Storage)]] || colspan="2"|1 generic || No || No || No || - || Attach pipes to [[Gas Canister]]s (removable, inventory-portable fluid storage).
 
|-
 
|-
| [[Tank]] (Large and Small) || kit || x || x || 1w || switch || comp || 100W || function
+
| [[Tank Connector]] || [[Tank Connector|Kit (Tank Connector)]] || colspan="2"|1 generic || No || No || No || - || Attach pipes to [[Portable Tank]]s (removable, luggable fluid storage), and also to [[Portable Air Scrubber]]s and [[Portable Air Conditioner]]s.
 
|-
 
|-
| [[Tank Connector]] || kit || x || x || 1w || switch || comp || 100W || function
+
| [[Tank]] (Large and Small) || [[Tank|Kit (Tank)]] || colspan="2"|1 generic || No || Logic only? || No || - || Permanent, high-capacity fluid storage.
 
|}
 
|}
  
Line 42: Line 42:
 
'''One-way''': Does the component prevent fluid from flowing the wrong way, from output to input?
 
'''One-way''': Does the component prevent fluid from flowing the wrong way, from output to input?
  
'''Switched''': Does it prevent all flow when switched off or unpowered? All switched components can be switched either manually or using [[Kit (Logic I/O)|logic circuits]].
+
'''Switched''': Does it prevent all flow when switched off or unpowered? Except where noted, switched components can be switched either manually or using [[Kit (Logic I/O)|logic circuits]].
  
 
'''Compressor''': Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output, or it does not enable any pressure changes.
 
'''Compressor''': Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output, or it does not enable any pressure changes.

Revision as of 12:43, 26 May 2020

This is a quick reference to the various components of a piped-fluid network.

Component Kit Inputs Outputs One-way? Switched? Compressor? Max. Power Primary Function
Pipe (various shapes) Kit (Pipe) 2-6 generic No No No - Provide a pathway.
Pipe Valve Kit (Pipe Valve) 2 generic No Manual No - Open/close flow manually.
Pipe Digital Valve Kit (Digital Valve) 2 generic No Yes No 25W Open/close flow using logic circuits.
Pipe Volume Pump Kit (Volume Pump) 1 1 Yes Yes Yes 800W, varies Pump fluid at adjustable rate.
Pressure Regulator Kit (Pressure Regulator) 1 1 Yes Yes Yes 100W Achieve target pressure at output.
Back Pressure Regulator Kit (Pressure Regulator) 1 1 Yes Yes Yes 100W Achieve target pressure at input.
Pipe Gas Mixer Kit (Gas Mixer) 2 1 Yes Yes Yes1 100W Combine two input mixes into one output mix, at an adjustable ratio.
Filtration Kit (Atmospherics) 1 2 Yes Yes Yes 5W Separate an input mix into a pure output and a "leftover" output.
Electrolyzer Kit (Atmospherics) 1 1 Yes Yes Yes 1,400W From input H2O, output mixed O2 and Volatiles.
Air Conditioner Kit (Atmospherics) 1 2 Yes Yes Yes 7,000W, varies Heat or cool a fluid: From input, split heat between right-temperature and wrong-temperature outputs.
Wall Cooler Kit (Wall Cooler) space 1 Yes, for heat2 Yes, for heat2 Yes, for heat2  ? Actively remove heat from a space into a pipe.
Active Vent Kit (Active Vent) 1 pipe, 1 space Yes, reversable Yes Yes 100W Pump pressure between a space and a pipe.
Passive Vent Kit (Passive Vent) 1 pipe, 1 space No No No - Equalize pressure between a space and a pipe.
Gas Tank Storage Kit (Canister Storage) 1 generic No No No - Attach pipes to Gas Canisters (removable, inventory-portable fluid storage).
Tank Connector Kit (Tank Connector) 1 generic No No No - Attach pipes to Portable Tanks (removable, luggable fluid storage), and also to Portable Air Scrubbers and Portable Air Conditioners.
Tank (Large and Small) Kit (Tank) 1 generic No Logic only? No - Permanent, high-capacity fluid storage.

Kit: The item used to build the component. All of these items are manufactured with a Hydraulic Pipe Bender or Fabricator, except where noted.

One-way: Does the component prevent fluid from flowing the wrong way, from output to input?

Switched: Does it prevent all flow when switched off or unpowered? Except where noted, switched components can be switched either manually or using logic circuits.

Compressor: Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output, or it does not enable any pressure changes.

Note 1: While the Pipe Gas Mixer will actively compress from output to input, it will stop when either input is empty, to preserve the mix ratio.

Note 2: The Wall Cooler's one-way, switched, and "compressor" qualities apply only to the heat exchange. It does not directly affect the pressure or flow in its attached pipe.