Kit (Gas Fuel Generator)
From Unofficial Stationeers Wiki
Revision as of 08:49, 19 January 2020 by Sunspots (talk | contribs) (Sunspots moved page Kit (Gas Generator) to Kit (Gas Fuel Generator))
Revision as of 08:49, 19 January 2020 by Sunspots (talk | contribs) (Sunspots moved page Kit (Gas Generator) to Kit (Gas Fuel Generator))
Recipe | |
---|---|
Created With | Fabricator,Electronics Printer |
Cost | 50x Iron, 10x Copper |
Construction | |
---|---|
Placed with | Kit (Gas Fuel Generator) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Gas Fuel Generator) |
Description
As the big brother of the Portable Generator the Gas Generator requires fuel and outputs crazy amounts of power if you don't throttle it's gas input.
Notes
- Use a pressure regulator on the input and start it as low as 1kpa, recommended to connect to a Kit (Battery) and to automate it as backup power.
Can be used in conjunction with a Electrolyzer to generate it's fuel.
- Requires to be placed in an atmosphere to work. Minimum pressure of 20 kPA and temperature ranging between 278-328 degrees Kelvin (5-55 Celsius)
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
Parameter Name | Data Type | Description |
---|---|---|
Setting | Float | (Unknown) Affects the Setting output. |
On | Boolean | Turns the Gas Generator on, when set to 1. Turns it off, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Gas Generator is turned on and receives power. (0 for no, 1 for yes) |
Error | Boolean | Returns whether the Gas Generator is flashing an error. (0 for no, 1 for yes) |
Pressure | Float | Returns the pressure in the Gas Generator in kilo pascal. |
Temperature | Float | Returns the temperature in the Gas Generator in kelvin. |
Setting | Float | (Unknown) Affected by the Setting parameter. |
RatioOxygen | Float | Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of oxygen in the Gas Generator. |
RatioCarbonDioxide | Float | Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of carbon dioxide in the Gas Generator. |
RatioNitrogen | Float | Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of nitrogen in the Gas Generator. |
RatioPollutant | Float | Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of pollutant in the Gas Generator. |
RatioVolatiles | Float | Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of volatiles in the Gas Generator. |
RatioWater | Float | Returns a range from 0.0 to 1.0. Returns the percentage ratio of the amount of water in the Gas Generator. |
Maximum | Integer | (Unknown) Returns 100. |
Ratio | Float | (Unknown) Returns 0.5. |
On | Boolean | Returns whether the Gas Generator is turned on. (0 for no, 1 for yes) |