Active Vent
From Unofficial Stationeers Wiki
Revision as of 04:33, 8 July 2018 by F1r3w4rr10r (talk | contribs) (Update to use the new Data Network templates)
Revision as of 04:33, 8 July 2018 by F1r3w4rr10r (talk | contribs) (Update to use the new Data Network templates)
Properties | |
---|---|
Stacks | Yes (5) |
Recipe | |
Created With | Hydraulic Pipe Bender, Fabricator |
Cost | 5g Iron, 1g Gold, 5g Copper |
Operation | |
---|---|
Power Usage | 100W |
Construction | |
Placed with | Active Vent (Item) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Active Vent (Item) |
Contents
Description
Used to move gasses from pipes, by using its inward or outward switches. It needs to be powered to function.
Note: The insert slot currently takes any item and seems to have no effect.
Data Network Properties
These are all Data Network properties of this device.
Mode Values
These lists the values and meanings for the "Mode" property of the Active Vent.
Value | Meaning |
---|---|
0 | "Outward" mode (Pumping gas from the connected pipe network to the outside.) |
1 | "Inward" mode (Pumping gas from the outside to the connected pipe network.) |
2 | (Unknown) |
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Active Vent, when set to 1. Closes it, when set to 0. (Untested) |
Mode | Integer | Sets the Active Vent mode to the passed setting. (See Mode Values) |
PressureExternal | Float | Sets the desired external pressure of the space outside the Active Vent. (Untested) |
PressureInternal | Float | Sets the desired internal pressure of the pipe network, connected to the Active Vent. (Untested) |
Lock | Boolean | Locks the Active Vent, when set to 1. Unlocks it, when set to 0. |
Setting | Float | Takes a range from 0.0 to 100.0. (Assumption) This sets the percentage amount of pumping throughput of the Active Vent. |
On | Boolean | Turns the Active Vent on, when set to 1. Turns it off, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Active Vent is receiving power and is turned on. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Active Vent is open. (0 for no, 1 for yes) (Untested) |
Mode | Integer | Returns the setting of the current mode of the Active Vent. (See Mode Values) |
Error | Boolean | Returns whether the Active Vent is currently flashing an error. (0 for no, 1 for yes) |
PressureExternal | Float | Returns the desired external pressure of the Active Vent. (Untested) |
PressureInternal | Float | Returns the desired internal pressure of the Active vent. (Untested) |
Lock | Boolean | Returns whether the Active Vent is locked. (0 for no, 1 for yes) |
Setting | Float | Returns a range from 0.0 to 100.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent. |
Maximum | Integer | Returns 100. (Assumption) Returns the maximum throughput percentage of the Active Vent. |
Ratio | Float | Returns a range from 0.0 to 1.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent. |
On | Boolean | Returns whether the Active Vent is set to on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power needed for the Active Vent. |