Atmospherics
From Unofficial Stationeers Wiki
Revision as of 12:48, 7 April 2018 by F1r3w4rr10r (talk | contribs) (Adjust logic properties for new patch)
Properties | |
---|---|
Stacks | no |
Recipe | |
Created With | Hydraulic Pipe Bender, Fabricator |
Cost | 10g Iron, 5g Gold, 20g Copper |
Construction | |
---|---|
Placed with | {{{placed_with_item}}} |
Placed on | {{{placed_on_grid}}} |
Contents
Air Conditioner Unit
Description
Used to lower and raise the temperature fed through it from the input pipe.
It has a range from -99 to 99 Celsius for the output
If the coolant pipe does not have 100kpa pressure it will divert output to coolant waste port to fill its coolant pipe
Usage
Place the Kit (Atmospherics) and run some pipes to the place you want to vent the heat. Place a few Pipe Radiators on the pipe, fill it with whatever gas mixture you want.
Make a return loop on the coolant system back to the coolant waste port for a slightly better efficiency.
It will try to draw or expel heat to the coolant mix to make the input match the desired output.
Logic Properties
These are all logic properties of this device.
Logic Parameters
These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Starts the Air Conditioner Unit, when set to 1. Stops it, when set to 0. |
Mode | Integer | (Unknown) (Judging by the "Mode" output, it accepts values in the range 0-2.) |
Lock | Boolean | Locks the Air Conditioner Unit, when set to 1. Unlocks it, when set to 0. |
On | Boolean | Turns the Air Conditioner Unit on, when set to 1. Turns it off, when set to 0. |
Logic Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Air Conditioner Unit is turned on and receives power. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Air Conditioner Unit is running. (0 for no, 1 for yes) |
Mode | Integer | (Unknown) (Returns output in the range 0-2, equivalent to the input of the "Mode" parameter.) |
Error | Boolean | Returns whether the Air Conditioner Unit is flashing an error. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the Air Conditioner Unit is locked. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Air Conditioner Unit is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power, required by the Air Conditioner, in Watts. |
Filtration Unit
Description
Used to filter out specific gasses and fluids from a mixture.
it can filter out up to 2 things at once
Usage
Place the Kit (Atmospherics) and change the variant to Filtration.
Place filters in the machine for what you want to filter out.
There are three filtration pipe connections.
Filtration Input is where you connect the incoming atmosphere to be passed through the Filtration Atmospherics.
Filtration Waste is the remaining mix after extracting whatever the filters did.
Filtration Output is the filtered material for which you placed filters in the machine for.
Logic Properties
These are all logic properties of this device.
Logic Parameters
These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
Parameter Name | Data Type | Description |
---|---|---|
On | Boolean | Turns the Filtration Unit on, when set to 1. Turns it off, when set to 0. |
Logic Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Filtration Unit is turned on and receives power. (0 for no, 1 for yes) |
Error | Boolean | Returns whether the Filtration Unit is flashing an error. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Filtration Unit is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power, required by the Filtration Unit, in Watts. |