Active Vent
From Unofficial Stationeers Wiki
Revision as of 05:00, 7 April 2018 by F1r3w4rr10r (talk | contribs) (Add logic properties and structure box)
Revision as of 05:00, 7 April 2018 by F1r3w4rr10r (talk | contribs) (Add logic properties and structure box)
Properties | |
---|---|
Stacks | Yes (5) |
Recipe | |
Created With | Hydraulic Pipe Bender, Fabricator |
Cost | 5g Iron, 1g Gold, 5g Copper |
Construction | |
---|---|
Placed with | {{{placed_with_item}}} |
Placed on | {{{placed_on_grid}}} |
Description
Used to move gasses from pipes, by using its inward or outward switches. It needs to be powered to function.
Note: The insert slot currently takes any item and seems to have no effect.
Logic Properties
These are all logic properties of this device.
Mode Values
These lists the values and meanings for the "Mode" property of the Active Vent.
Value | Meaning |
---|---|
0 | "Outward" mode (Pumping gas from the connected pipe network to the outside.) |
1 | "Inward" mode (Pumping gas from the outside to the connected pipe network.) |
2 | (Unknown) |
Logic Parameters
These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Active Vent, when set to 1. Closes it, when set to 0. (Untested) |
Mode | Integer | Sets the Active Vent mode to the passed setting. (See Mode Values) |
PressureExternal | Float | Sets the desired external pressure of the space outside the Active Vent. (Untested) |
PressureInternal | Float | Sets the desired internal pressure of the pipe network, connected to the Active Vent. (Untested) |
Lock | Boolean | Locks the Active Vent, when set to 1. Unlocks it, when set to 0. |
Setting | Float | Takes a range from 0.0 to 100.0. (Assumption) This sets the percentage amount of pumping throughput of the Active Vent. |
On | Boolean | Turns the Active Vent on, when set to 1. Turns it off, when set to 0. |
Logic Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Active Vent is receiving power and is turned on. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Active Vent is open. (0 for no, 1 for yes) (Untested) |
Mode | Integer | Returns the setting of the current mode of the Active Vent. (See Mode Values) |
Error | Boolean | Returns whether the Active Vent is currently flashing an error. (0 for no, 1 for yes) |
PressureExternal | Float | Returns the desired external pressure of the Active Vent. (Untested) |
PressureInternal | Float | Returns the desired internal pressure of the Active vent. (Untested) |
Lock | Boolean | Returns whether the Active Vent is locked. (0 for no, 1 for yes) |
Setting | Float | Returns a range from 0.0 to 100.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent. |
Maximum | Integer | Returns 100. (Assumption) Returns the maximum throughput percentage of the Active Vent. |
Ratio | Float | Returns a range from 0.0 to 1.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent. |
On | Boolean | Returns whether the Active Vent is set to on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power needed for the Active Vent. |