Stacker
From Unofficial Stationeers Wiki
Recipe | |
---|---|
Created With | Autolathe, Fabricator |
Cost | 10g Iron, 2g Copper |
Contents
Description[edit]
The kit has 3 variations : 2 are the Stacker, with the power/data port on one side or the other. The last variant is the Unloader
Stacker[edit]
Operation | |
---|---|
Power Usage | 50W |
Construction | |
Placed with | Kit (Stacker) |
Placed on | Small Grid |
Slots | |
Slot 0 | Import |
Slot 1 | Export |
Slot 2 | Inside Machine |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Stacker) |
Used to stack items in a chosen quantity. The stacker holds back the input until the configured quantity can be stacked _or_ until the input item type changes. If the input is bigger than the chosen quantity, the stacker (despite its name) splits it.
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Mode | Integer | 0 = Automatic stacking and export, 1 = Stack and hold until Activate = 1 |
Activate | Boolean | If set to 1, the Stacker will clear its content via its Export Slot without regard to the Setting |
Lock | Boolean | |
Setting | Integer | Default is 1. Sets the Stack Size (won't actually stack to that size if item's max stack size is smaller) |
On | Boolean | |
ClearMemory | Integer? | Writing on this Parameter will reset the ExportCount and ImportCount values to zero. |
Output | Integer | Value of 0 for Mode 0. If you set this to 1 while in Mode 1 the stacker will export a batch of items from storage with quantity Setting. If there are not enough items in storage, they will not be output. |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Mode | Boolean | |
Lock | Boolean | |
ImportCount | Integer | Incremented each time an item stack enter by the Import slot |
ExportCount | Integer | Incremented each time an item stack exit by the Export Slot |
Error | Boolean | |
Activate | Boolean | 1 if empty, 0 if something is inside the Stacker. When set to 0 The player can use the lever to clear the Stacker |
Setting | Integer | Default is 1. Shows the Stack Size this Stacker is set to. |
RequiredPower | Integer | In watts. The Stacker requires 5W to operate. |
PrefabHash | Float | Hash ID of the Stacker. |
Power | Boolean | |
Output | Integer | Value of 0 in Mode 0. Mode 1 sets this to -1. |
On | Boolean |
Notes[edit]
The stacker can only stack things up to the stacking limit of the given item:
- Ingots can be stacked up to 500.
- Ore will not stack over 50.
Unloader[edit]
Operation | |
---|---|
Power Usage | 50W |
Construction | |
Placed with | Kit (Stacker) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Stacker) |
The unloader variant will empty the content of a belt/container. It will output everything that is inside, followed by belt/container itself.
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Mode | Integer | 0 = automatic export, 1 = holds export until Output set |
Lock | Boolean | |
On | Boolean | |
ClearMemory | Integer? | Writing on this Parameter will reset the ExportCount and ImportCount values to zero. |
Output | Integer | Value of 0 in Mode 0. Mode 1 sets this to -1 as default. Writing a 0 (import) will export the entire container and reset Output to -1, 1 (export) will export a single item stack from the container and will reset Output to -1 |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | |
Mode | Boolean | |
Error | Boolean | |
Lock | Boolean | |
On | Boolean | |
RequiredPower | Integer | In watts. The Unloader require 50W to operate. |
ExportCount | Integer | Incremented each time an item stack exit by the Export Slot |
ImportCount | Integer | Incremented each time an item stack enter by the Import slot |
Output | Integer | Value of 0 for Mode 0. Mode 1 sets this to -1(hold output) and will reset after output is written and an item is exported. |