Basic Chutes
From Unofficial Stationeers Wiki
Properties | |
---|---|
Stacks | Yes (10) |
Recipe | |
Created With | Autolathe, Fabricator, Hydraulic Pipe Bender |
Cost | 1g Iron* |
Construction | |
---|---|
Placed with | Kit (Chutes) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Wrench |
Item received | Kit (Chutes) |
Contents
Chute
Description
Used to transport items. The Kit can be used to create 9 different variants, some of them are able to connect to power and logic network.
- Straight chute: transports items on a straight line
- Window chute: transports items on a straight line, and the items are visible inside the chute
- Corner chute: transports items on a perpendicular line
- Junction (consumes two kits): transports items on a straight and perpendicular line (merges two lines into one)
- Flip flop Splitter: alternates between transporting an item on a straight and perpendicular line (splits one line in two)
- Chute Valve: transports items on a straight line. Can be open and closed
- Chute overflow: transports items on a straight and perpendicular line, where priority is given to the straight line (similar to a flip flop, but instead of 50%, it only goes perpendicular if straight is full)
- Chute inlet: items can be dropped on it and will transport them on a perpendicular line
- Chute outlet: items are dropped from the chute to the floor
Recipes
Manufactory | Materials | Time | Energy |
---|---|---|---|
Autolathe | 3g Iron | 5 | 500 |
Hydraulic Pipe Bender | 3g Iron | 5 | 500 |
Recycler | 1,5g Iron | 5 | 1000 |
Chute Bin
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Chute Bin, when set to 1. Closes it, when set to 0. |
On | Boolean | Turns the Chute Bin on when set to 1. Turns it off, when set to 0. |
Lock | Boolean | Prevents the player from pulling the lever on the Chute Bin. 1 = Locked, 0 = Unlocked. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Chute Bin is turned on and receives power. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Chute Bin is open. (0 for no, 1 for yes) |
Error | Boolean | Returns whether the Chute Bin is flashing an error. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Chute Bin is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power, required by the Chute Bin, in watts. |
Chute Outlet
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Chute Outlet when set to 1. |
Lock | Boolean | Locks the Chute Outlet when set to 1. Unlocks it, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Open | Boolean | Returns whether the Chute Outlet is open. (0 for no, 1 for yes) This only returns 1 briefly, when the Chute Outlet opens. |
Lock | Boolean | Returns whether the Chute Outlet is locked. (0 for no, 1 for yes) |
ImportQuantity | Integer | Returns the number of items, the Chute Outlet is holding, in grams. |
ImportSlotOccupant | Boolean | Returns whether the Chute Outlet is holding an item. (0 for no, 1 for yes) |
Chute Inlet
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Parameter Name | Data Type | Access | Value | Description |
---|
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Lock | Boolean | 1 if the inlet is locked, 0 if it is not. |
ImportCount | Integer | Returns the number of stacks imported by the inlet. |
PrefabHash | Integer | Returns a hash. (Chute Inlet ItemID?) |