Power Controller
From Unofficial Stationeers Wiki
Max Input Power |
10W for the APC + 1000W Battery Charging + Output Load |
---|---|
Max Output Power | No Limit |
Properties | |
Stacks | Yes (5) |
Recipe | |
Created With | Electronics Printer, Fabricator |
Cost | 5g Iron, 2g Copper, 3g Solder |
Construction | |
---|---|
Placed with | {{{placed_with_item}}} |
Placed on | {{{placed_on_grid}}} |
Contents
Description
The Area Power Controller is used to segregate power into their own subnetworks and reduce power fluctuations.
Usage
The APC can be opened with a Crowbar, once opened the switch must be set to the 'ON' state for it to function. A Battery Cell can be added to act as a power buffer for the subnetwork in the event the main power network gets disconnected. Currently, the dials in the APC do nothing.
The APC can generally be used for machines with varying power requirements such as the Auto lathe, Electronics Printer, Fabricator, Arc Furnace, and more. This will allow all these machines to take lots of power in short intervals as long as the APC has a battery. This is a similar object to the Transformer that only allows a specified amount of power through.
If sufficient power is available upstream, the APC acts as a pass through and will not limit it's output power, it is recommended to use a Cable Fuse or Transformer (Small) when powering a non-heavy cable network to prevent overdraw.
Data Network Properties
These are all Data Network properties of this device. There is no difference in parameters, whether the logic network is connected to the input or output of the Area Power Control.
Mode Values
This shows the values of the "Mode" property, mapped to what the display will show.
Value | Display | Meaning |
---|---|---|
0 | Grey | No output power draw or the Area Power Control is turned off. |
1 | Red | No battery in the Area Power Control and there is power drawn from the output. |
2 | Blue-red blinking | There is a battery in the Area Power Control, the output draw is greater than the input and the battery is discharging. |
3 | Blue-green blinking | There is a battery in the Area Power Control, the output draw is less than the input and the battery is charging. |
4 | Green | There is a battery in the Area Power Control, the output draw is less than the input and the battery is fully charged. |
5 | Grey | (Unknown) |
Data Parameters
These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Area Power Control lid, when set to 1. Closes it, when set to 0. |
Mode | Integer | Sets the mode to the passed value. This will only be set for less than a second, before the Area Power Control will override it with it's current mode. (See Mode Values) |
Lock | Boolean | Locks the Area Power Control, when set to 1. Unlocks it, when set to 0. |
On | Boolean | Turns the Area Power Control on, when set to 1. Turns it off, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Area Power Control is receiving power and is turned on. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Area Power Control is open. (0 for no, 1 for yes) |
Mode | Integer | Returns the current mode of the Area Power Control. (See Mode Values) |
Error | Boolean | Returns whether the Area Power Control is flashing an error. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the Area Power Control is locked. (0 for no, 1 for yes) |
Charge | Integer | Returns the currently available power, that can be output, in Watts. (Input power plus the charge of the battery in the Area Power Control.) |
Maximum | Integer | Returns the maximum charge of the battery in the Area Power Control, in Watts. |
Ratio | Float | Returns a range from 0.0 to 1.0. It returns the current charge percentage of the battery in the Area Power Control. |
PowerPotential | Integer | Returns the current amount of power, available to the Area Power Control input, in Watts. |
PowerActual | Integer | Returns the current amount of power, output by the Area Power Control, in Watts. |
On | Boolean | Returns whether the Area Power Control is on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power needed at the input, in Watts. (This includes the amount of power draw of the battery inside.) |
History
- In older versions of the game, the APC had specific Input and Output connection sides until a later update added a variant of the APC with reversed sides.
- In older versions of the game, a battery must be placed in the APC for it to function. This is no longer the case after the power rework update in v0.1.1062.5426 as you do not need a battery in the APC for it to function anymore.