Powered Vent
From Unofficial Stationeers Wiki
Revision as of 23:16, 29 September 2025 by Banangecko (talk | contribs) (Updated strength comparison)
![]() | |
| Constructing Options | Powered Vent, Powered Vent Large |
|---|---|
| Properties | |
| Stacks | Yes (5) |
| Recipes | |
| Hydraulic Pipe Bender (Tier Two) | 5g Steel, 5g Electrum, 2g Invar |
| Logic | |
| Item Hash | 2015439334 |
| Item Name | ItemKitPoweredVent |
| Logic Classes |
SlotClass.None SortingClass.Kits |
| File:StructurePoweredVent.png | |
| Operation | |
|---|---|
| Power Usage | 250W |
| Prefab Hash | 938836756 |
| Prefab Name | StructurePoweredVent |
| Construction | |
| Placed with | Kit (Powered Vent) |
| Placed on | Small Grid |
| Stage 1 | |
| Next Stage Construction | |
| Constructed with tool | Screwdriver |
| Constructed with item | 2 x Kit (Pipe) |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | Kit (Powered Vent) |
| Stage 2 | |
| Next Stage Construction | |
| Constructed with tool | Welding Torch |
| Constructed with item | 2 x Plastic Sheets |
| Deconstruction | |
| Deconstructed with | Wrench |
| Stage 3 | |
| Deconstruction | |
| Deconstructed with | Angle Grinder |
| File:StructurePoweredVentLarge.png | |
| Operation | |
|---|---|
| Power Usage | 500W |
| Prefab Hash | -785498334 |
| Prefab Name | StructurePoweredVentLarge |
| Construction | |
| Placed with | Kit (Powered Vent) |
| Placed on | Small Grid |
| Stage 1 | |
| Next Stage Construction | |
| Constructed with tool | Screwdriver |
| Constructed with item | 2 x Electronic Parts |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | Kit (Powered Vent) |
| Stage 2 | |
| Next Stage Construction | |
| Constructed with tool | Welding Torch |
| Constructed with item | 4 x Plastic Sheets |
| Deconstruction | |
| Deconstructed with | Wrench |
| Stage 3 | |
| Deconstruction | |
| Deconstructed with | Angle Grinder |
Contents
Description
Powered vents move air and pull vacuum far more quickly than an active vent. Powered vents have a unique behavior to "scavenge" air from grids outside the one it's built on once the pressure is low enough (~20kpa), skipping the wait for the last few pascals of gas to diffuse into the vent.
Powered Vent
Great for moving large quantities of air into a pipe network. Its primary purpose is for the creation of multi-grid airlocks. It can efficiently pull a vacuum on a small to medium sized room.
- Stationpedia
By moles per tick, pulls inward ~2.04x and blows outward about 2.14x as much as an active vent. Scavenge range 9x9x9 large grid centered on vent.
Powered Vent Large
For building large scale airlock systems and pressurized hangars, a bigger and bolder version of the powered vent that can efficiently pull a vacuum in large room.
- Stationpedia
By moles per tick, pulls inward ~4.14x and blows outward about 4.34x as much as an active vent. Scavenge range 13x13x13 large grid centered on vent.
Data Network Properties
These are all Data Network properties of this device.
Mode Values
These list the values and meanings for the "Mode" property of the Power Vent/Large.
| Value | Meaning |
|---|---|
| 0 | "Outward" mode (Moves gas from the connected pipe network to the surrounding atmosphere.) |
| 1 | "Inward" mode (Moves gas from the surrounding atmosphere to the connected pipe network.) |
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
| Parameter Name | Data Type | Access | Value | Description | ||
|---|---|---|---|---|---|---|
| Power | Boolean | Read
|
0 | Off | Can be read to return if the device is correctly powered or not, set via the power system, returns 1 if powered and 0 if not | |
| 1 | On | |||||
| PressureExternal | Float | Read Write
|
||||
| Mode | Integer | Read Write
|
0 | Outward | The mode of the Power Vent. | |
| 1 | Inward | |||||
| Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Power Vent. | |
| 1 | Locked | |||||
| On | Boolean | Read Write
|
0 | Off | The current state of the Power Vent. | |
| 1 | On | |||||
| RequiredPower | Integer | Read
|
||||
| PrefabHash | Integer | Read
|
||||
| ReferenceId | Integer | Read
|
||||
| NameHash | Integer | Read
|
||||

