Basic Chutes
From Unofficial Stationeers Wiki
Revision as of 05:52, 20 May 2024 by Emilgardis (talk | contribs)
Constructing Options | Chute (Straight), Chute (Corner), Chute (Window), Chute (Junction), Chute Flip Flop Splitter, Chute Valve, Chute Overflow, Chute Inlet, Chute Outlet |
---|---|
Properties | |
Stacks | Yes (10) |
Recipes | |
Autolathe | 3g Iron |
Hydraulic Pipe Bender | 3g Iron |
Logic | |
Item Hash | 1025254665 |
Item Name | ItemKitChute |
Logic Classes |
SlotClass.None SortingClass.Kits |
Construction | |
---|---|
Placed with | Kit (Chutes) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Wrench |
Item received | Kit (Chutes) |
Contents
Chute
Description
Used to transport items. The Kit can be used to create 9 different variants, some of them are able to connect to power and logic network.
- Straight chute: transports items on a straight line
- Window chute: transports items on a straight line, and the items are visible inside the chute
- Corner chute: transports items on a perpendicular line
- Junction (consumes two kits): transports items on a straight and perpendicular line (merges two lines into one)
- Flip flop Splitter: alternates between transporting an item on a straight and perpendicular line (splits one line in two)
- Chute Valve: transports items on a straight line. Can be open and closed
- Chute overflow: transports items on a straight and perpendicular line, where priority is given to the straight line (similar to a flip flop, but instead of 50%, it only goes perpendicular if straight is full)
- Chute inlet: items can be dropped on it and will transport them on a perpendicular line
- Chute outlet: items are dropped from the chute to the floor
Recipes
Manufactory | Materials | Time | Energy |
---|---|---|---|
Autolathe | 3g Iron | 5 | 500 |
Hydraulic Pipe Bender | 3g Iron | 5 | 500 |
Recycler | 1,5g Iron | 5 | 1000 |
Chute Bin
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Power | Boolean | Read
|
0 | Unpowered | Can be read to return if the Chute Bin is correctly powered or not, set via the power system, return 1 if powered and 0 if not | |
1 | Powered | |||||
Open | Integer | Read Write
|
||||
Error | Boolean | Read
|
0 | 1 if device is in error state, otherwise 0 | ||
1 | Error | |||||
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Chute Bin. | |
1 | Locked | |||||
On | Boolean | Read Write
|
0 | Off | The current state of the Chute Bin. | |
1 | On | |||||
RequiredPower | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|
Chute Outlet
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Chute Outlet. | |
1 | Locked | |||||
ClearMemory | Integer | Write
|
||||
ExportCount | Integer | Read
|
||||
ImportCount | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|
Chute Inlet
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
Parameter Name | Data Type | Access | Value | Description | ||
---|---|---|---|---|---|---|
Lock | Boolean | Read Write
|
0 | Unlocked | Disable manual operation of the Chute Inlet. | |
1 | Locked | |||||
ClearMemory | Integer | Write
|
||||
ImportCount | Integer | Read
|
||||
PrefabHash | Integer | Read
|
||||
ReferenceId | Integer | Read
|
||||
NameHash | Integer | Read
|