Difference between revisions of "Atmospheric Components Quick Reference"
From Unofficial Stationeers Wiki
TheNicestGuy (talk | contribs) (Digital Valve: Add link to Logic I/O.) |
TheNicestGuy (talk | contribs) (Add Kit column.) |
||
Line 3: | Line 3: | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
− | ! Component !! Inputs !! Outputs !! One-way? !! Switched? !! Compressor? !! Max. Power !! Primary Function | + | ! Component !! Kit !! Inputs !! Outputs !! One-way? !! Switched? !! Compressor? !! Max. Power !! Primary Function |
|- | |- | ||
− | | [[Pipes|Pipe]] (various shapes) || colspan="2"|2-6 generic || No || No || No || - || Provide a pathway. | + | | [[Pipes|Pipe]] (various shapes) || [[Pipes]] || colspan="2"|2-6 generic || No || No || No || - || Provide a pathway. |
|- | |- | ||
− | | [[Pipe Valve]] || colspan="2"|2 generic || No || Manual || No|| -|| Open/close flow manually. | + | | [[Pipe Valve]] || [[Pipe Valve]] || colspan="2"|2 generic || No || Manual || No|| -|| Open/close flow manually. |
|- | |- | ||
− | | [[Pipe Digital Valve]] || colspan="2"|2 generic || No || Yes || No || 25W || Open/close flow using [[Kit (Logic I/O)|logic circuits]]. | + | | [[Pipe Digital Valve]] || [[Pipe Digital Valve]] || colspan="2"|2 generic || No || Yes || No || 25W || Open/close flow using [[Kit (Logic I/O)|logic circuits]]. |
|- | |- | ||
− | | [[Pipe Volume Pump]] || 1 || 1 || Yes || Yes || Yes || 800W, varies || Pump fluid at adjustable rate. | + | | [[Pipe Volume Pump]] || [[Pipe Volume Pump]] || 1 || 1 || Yes || Yes || Yes || 800W, varies || Pump fluid at adjustable rate. |
|- | |- | ||
− | | [[Pressure_Regulator#Pressure_Regulator|Pressure Regulator]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at output. | + | | [[Pressure_Regulator#Pressure_Regulator|Pressure Regulator]] || [[Pressure Regulator]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at output. |
|- | |- | ||
− | | [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at input. | + | | [[Pressure_Regulator#Back_Pressure_Regulator|Back Pressure Regulator]] || [[Pressure Regulator]] || 1 || 1 || Yes || Yes || Yes || 100W || Achieve target pressure at input. |
|- | |- | ||
− | | [[Pipe Gas Mixer]] || 2 || 1 || Yes || Yes || Yes<sup>1</sup> || 100W || Combine two input mixes into one output mix, at an adjustable ratio. | + | | [[Pipe Gas Mixer]] || [[Pipe Gas Mixer]] || 2 || 1 || Yes || Yes || Yes<sup>1</sup> || 100W || Combine two input mixes into one output mix, at an adjustable ratio. |
|- | |- | ||
− | | [[Kit (Atmospherics) Filtration|Filtration]] || 1 || 2 || Yes || Yes || Yes || 5W || Separate an input mix into a pure output and a "leftover" output. | + | | [[Kit (Atmospherics) Filtration|Filtration]] || [[Kit (Atmospherics)]] || 1 || 2 || Yes || Yes || Yes || 5W || Separate an input mix into a pure output and a "leftover" output. |
|- | |- | ||
− | | [[Kit (Atmospherics) Electrolyzer|Electrolyzer]] || 1 || 1 || Yes || Yes || Yes || 1,400W || From input [[water|H<sub>2</sub>O]], output mixed [[Oxygen|O<sub>2</sub>]] and [[Volatiles]]. | + | | [[Kit (Atmospherics) Electrolyzer|Electrolyzer]] || [[Kit (Atmospherics)]] || 1 || 1 || Yes || Yes || Yes || 1,400W || From input [[water|H<sub>2</sub>O]], output mixed [[Oxygen|O<sub>2</sub>]] and [[Volatiles]]. |
|- | |- | ||
− | | [[Active Vent]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe. | + | | [[Active Vent]] || [[Active Vent]] || colspan="2"|1 pipe, 1 space || Yes, reversable || Yes || Yes || 100W || Pump pressure between a space and a pipe. |
|- | |- | ||
− | | [[Passive Vent]] || colspan="2"|1 pipe, 1 space || No || No || No || - || Equalize pressure between a space and a pipe. | + | | [[Passive Vent]] || [[Passive Vent]] || colspan="2"|1 pipe, 1 space || No || No || No || - || Equalize pressure between a space and a pipe. |
|- | |- | ||
− | | [[Wall Cooler]] || x || x || 1w || switch || comp || 100W || function | + | | [[Wall Cooler]] || [[Wall Cooler]] || x || x || 1w || switch || comp || 100W || function |
|- | |- | ||
− | | [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || x || x || 1w || switch || comp || 100W || function | + | | [[Kit (Atmospherics) Air Conditioner|Air Conditioner]] || [[Kit (Atmospherics)]] || x || x || 1w || switch || comp || 100W || function |
|- | |- | ||
− | | [[Gas Tank Storage]] || x || x || 1w || switch || comp || 100W || function | + | | [[Gas Tank Storage]] || kit || x || x || 1w || switch || comp || 100W || function |
|- | |- | ||
− | | [[Tank]] (Large and Small) || x || x || 1w || switch || comp || 100W || function | + | | [[Tank]] (Large and Small) || kit || x || x || 1w || switch || comp || 100W || function |
|- | |- | ||
− | | [[Tank Connector]] || x || x || 1w || switch || comp || 100W || function | + | | [[Tank Connector]] || kit || x || x || 1w || switch || comp || 100W || function |
|} | |} | ||
+ | |||
+ | '''Kit''': The item used to build the component. All of these items are manufactured with a [[Hydraulic Pipe Bender]] or [[Fabricator]], except where noted. | ||
'''One-way''': Does the component prevent gas from flowing the wrong way, from output to input? | '''One-way''': Does the component prevent gas from flowing the wrong way, from output to input? | ||
− | '''Switched''': Does it prevent all gas flow when switched off or unpowered? | + | '''Switched''': Does it prevent all gas flow when switched off or unpowered? All switched components can be switched either manually or using [[Kit (Logic I/O)|logic circuits]]. |
'''Compressor''': Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output. | '''Compressor''': Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output. | ||
'''Note 1:''' While the Pipe Gas Mixer will actively compress from output to input, it will stop when either input is empty, to preserve the mix ratio. | '''Note 1:''' While the Pipe Gas Mixer will actively compress from output to input, it will stop when either input is empty, to preserve the mix ratio. |
Revision as of 10:26, 26 May 2020
This is a quick reference to the traits of the various components of a piped-fluid network.
Component | Kit | Inputs | Outputs | One-way? | Switched? | Compressor? | Max. Power | Primary Function |
---|---|---|---|---|---|---|---|---|
Pipe (various shapes) | Pipes | 2-6 generic | No | No | No | - | Provide a pathway. | |
Pipe Valve | Pipe Valve | 2 generic | No | Manual | No | - | Open/close flow manually. | |
Pipe Digital Valve | Pipe Digital Valve | 2 generic | No | Yes | No | 25W | Open/close flow using logic circuits. | |
Pipe Volume Pump | Pipe Volume Pump | 1 | 1 | Yes | Yes | Yes | 800W, varies | Pump fluid at adjustable rate. |
Pressure Regulator | Pressure Regulator | 1 | 1 | Yes | Yes | Yes | 100W | Achieve target pressure at output. |
Back Pressure Regulator | Pressure Regulator | 1 | 1 | Yes | Yes | Yes | 100W | Achieve target pressure at input. |
Pipe Gas Mixer | Pipe Gas Mixer | 2 | 1 | Yes | Yes | Yes1 | 100W | Combine two input mixes into one output mix, at an adjustable ratio. |
Filtration | Kit (Atmospherics) | 1 | 2 | Yes | Yes | Yes | 5W | Separate an input mix into a pure output and a "leftover" output. |
Electrolyzer | Kit (Atmospherics) | 1 | 1 | Yes | Yes | Yes | 1,400W | From input H2O, output mixed O2 and Volatiles. |
Active Vent | Active Vent | 1 pipe, 1 space | Yes, reversable | Yes | Yes | 100W | Pump pressure between a space and a pipe. | |
Passive Vent | Passive Vent | 1 pipe, 1 space | No | No | No | - | Equalize pressure between a space and a pipe. | |
Wall Cooler | Wall Cooler | x | x | 1w | switch | comp | 100W | function |
Air Conditioner | Kit (Atmospherics) | x | x | 1w | switch | comp | 100W | function |
Gas Tank Storage | kit | x | x | 1w | switch | comp | 100W | function |
Tank (Large and Small) | kit | x | x | 1w | switch | comp | 100W | function |
Tank Connector | kit | x | x | 1w | switch | comp | 100W | function |
Kit: The item used to build the component. All of these items are manufactured with a Hydraulic Pipe Bender or Fabricator, except where noted.
One-way: Does the component prevent gas from flowing the wrong way, from output to input?
Switched: Does it prevent all gas flow when switched off or unpowered? All switched components can be switched either manually or using logic circuits.
Compressor: Will it actively increase pressure in the output and decrease pressure in the input? If no, the component only allows pressure to change toward equilibrium between input and output.
Note 1: While the Pipe Gas Mixer will actively compress from output to input, it will stop when either input is empty, to preserve the mix ratio.