Difference between revisions of "Glass Door"
From Unofficial Stationeers Wiki
m (Added references section and tag to fix a page formatting bug.) |
F1r3w4rr10r (talk | contribs) (Update to use the new Structurebox syntax) |
||
Line 9: | Line 9: | ||
| cost = 3g [[Copper Ore]], 7g [[Iron Ore]] | | cost = 3g [[Copper Ore]], 7g [[Iron Ore]] | ||
}} | }} | ||
− | {{ | + | {{Structurebox |
− | | name | + | | name = Glass Door |
− | | image | + | | image = [[File:{{#setmainimage:Glass door.jpg}}]] |
− | | | + | | power_usage = 25W |
− | | | + | | placed_with_item = [[Kit (Door)]] |
− | | | + | | placed_on_grid = Small Grid |
+ | | decon_with_tool1 = [[Hand Drill]] | ||
+ | | item_rec1 = [[Kit (Door)]] | ||
}} | }} | ||
== Description == <!--T:2--> | == Description == <!--T:2--> |
Revision as of 13:34, 1 July 2018
Properties | |
---|---|
Stacks | No |
Operation | |
---|---|
Power Usage | 25W |
Construction | |
Placed with | Kit (Door) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Door) |
Contents
Description
The Glass Doors are created by using building with a Kit (Door).
- They can be opened and closed from the panel, or from a Console equipped with Circuitboard (Door Control).
- They are airtight (when closed), and can withstand around 200kPa pressure, which is lower than Composite Doors, which can withstand around 300kPa. [1]
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Opens the Glass Door, when set >= 1. Closes it, when set to < 1. |
Lock | Boolean | Locks the Glass Door, when set >= 1. Unlocks it, when set to <1. |
On | Boolean | Turns the Glass Door on, when set >= 1. Turns it off, when set to <1. |
Data Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Glass Door is turned on and receives power. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Glass Door is open. (0 for no, 1 for yes) |
Lock | Boolean | Returns whether the Glass Door is locked. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Glass Door is turned on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power, required by the Glass Door, in watts. |