Difference between revisions of "Pipe Analyzer"
From Unofficial Stationeers Wiki
DerMarsianer (talk | contribs) (add RatioNitrousOxide to list of parameters) |
|||
Line 44: | Line 44: | ||
| RatioOxygen || Float || The ratio of oxygen in the pipe. A value between 0 (no oxygen at all, or 0%) and 1 ( pure oxygen atmosphere, or 100%) | | RatioOxygen || Float || The ratio of oxygen in the pipe. A value between 0 (no oxygen at all, or 0%) and 1 ( pure oxygen atmosphere, or 100%) | ||
|- | |- | ||
− | | RatioCarbonDioxide || Float || | + | | RatioCarbonDioxide || Float || ratio in mass percent / 100 |
|- | |- | ||
− | | RatioNitrogen || Float || | + | | RatioNitrogen || Float || ratio in mass percent / 100 |
|- | |- | ||
− | | | + | | RatioNitrousOxide|| Float || ratio in mass percent / 100 |
|- | |- | ||
− | | RatioVolatiles || Float || | + | | RatioPollutant || Float || ratio in mass percent / 100 |
+ | |- | ||
+ | | RatioVolatiles || Float || ratio in mass percent / 100 | ||
|- | |- | ||
| RatioWater || Float || | | RatioWater || Float || | ||
Line 58: | Line 60: | ||
| Requiredpower || Integer || In Watts. The Pipe Analyzer require 50W of power to function | | Requiredpower || Integer || In Watts. The Pipe Analyzer require 50W of power to function | ||
|- | |- | ||
− | | TotalMoles || Float || | + | | TotalMoles || Float || |
|} | |} | ||
</translate> | </translate> |
Revision as of 05:48, 3 July 2022
Properties | |
---|---|
Stacks | Yes (5) |
Recipe | |
Created With | Atmospherics, Fabricator |
Cost | 20g Iron, 2g Gold, 2g Copper, 2g Electrum |
Description
Just like the Pipe Meter it can be used to display the pressure inside the pipes, but also displaying the contents and temperature. It requires 50W of power and can be hooked up to consoles or computers.
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Lock | Boolean | |
On | Boolean |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | |
Error | Boolean | |
Pressure | Float | In kPa |
Temperature | Float | In Kelvin |
Lock | Boolean | |
RatioOxygen | Float | The ratio of oxygen in the pipe. A value between 0 (no oxygen at all, or 0%) and 1 ( pure oxygen atmosphere, or 100%) |
RatioCarbonDioxide | Float | ratio in mass percent / 100 |
RatioNitrogen | Float | ratio in mass percent / 100 |
RatioNitrousOxide | Float | ratio in mass percent / 100 |
RatioPollutant | Float | ratio in mass percent / 100 |
RatioVolatiles | Float | ratio in mass percent / 100 |
RatioWater | Float | |
On | Boolean | |
Requiredpower | Integer | In Watts. The Pipe Analyzer require 50W of power to function |
TotalMoles | Float |