Actions

Difference between revisions of "Elevator"

From Unofficial Stationeers Wiki

(Elevator Level: fixing more bad writing)
(show data properties)
Line 17: Line 17:
  
 
<hr>
 
<hr>
== Elevator Shaft ==
+
= Elevator Shaft =
 
{{Structurebox
 
{{Structurebox
 
  | name            = Elevator Shaft
 
  | name            = Elevator Shaft
Line 31: Line 31:
 
Currently does not require power.
 
Currently does not require power.
  
=== Data Network Properties ===
+
{{Data Network Header}}
<div class="toccolours mw-collapsible mw-collapsed">
 
These are all [[:Category:Data Network|Data Network]] properties of this device.
 
<div class="mw-collapsible-content">
 
  
==== Data Parameters ====
+
{{Data Parameters}}
These are all parameters, that can be written to with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]]. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
 
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 47: Line 43:
 
|}
 
|}
  
==== Data Outputs ====
+
{{Data Outputs}}
These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]]. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
 
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 63: Line 58:
 
| Elevatorlevel || Integer || Returns current level carriage is on
 
| Elevatorlevel || Integer || Returns current level carriage is on
 
|}
 
|}
</div>
 
</div>
 
  
 
<hr>
 
<hr>
== Elevator Level ==
+
= Elevator Level =
 
{{Structurebox
 
{{Structurebox
 
  | name            = Elevator Level
 
  | name            = Elevator Level
Line 80: Line 73:
 
Requires power to open the door automatically and use the call button
 
Requires power to open the door automatically and use the call button
  
=== Data Network Properties ===
+
{{Data Network Header}}
<div class="toccolours mw-collapsible mw-collapsed">
 
These are all [[:Category:Data Network|Data Network]] properties of this device.
 
<div class="mw-collapsible-content">
 
  
==== Data Parameters ====
+
{{Data Parameters}}
The following are parameters that can be written to with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]]. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
 
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 97: Line 86:
 
| On || Boolean || Turns the device on, when set >= 1. Turns it off, when set to <1.
 
| On || Boolean || Turns the device on, when set >= 1. Turns it off, when set to <1.
 
|-
 
|-
| Elevatorlevel || Integer || Write the level you want the carriage to go to
+
| Elevatorlevel || Integer || Write the level you want the carriage to go to.
 
|}
 
|}
  
==== Data Outputs ====
+
 
The following are parameters that can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]]. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
+
{{Data Outputs}}
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 118: Line 107:
 
| RequiredPower || Integer || Returns the current amount of power, required by the Glass Door, in watts.
 
| RequiredPower || Integer || Returns the current amount of power, required by the Glass Door, in watts.
 
|-
 
|-
| Elevatorspeed || Integer || Returns 1 going up, 0 standing still and -1 going down
+
| ElevatorSpeed || Integer || Returns 1 going up, 0 standing still and -1 going down
 
|-
 
|-
| Elevatorlevel || Integer || Returns current level carriage is on
+
| ElevatorLevel || Integer || Returns current level carriage is on
 
|}
 
|}
</div>
 
</div>
 

Revision as of 14:04, 1 September 2018

Kit (Elevator)
ItemKitElevator.png
Constructing Options Elevator Shaft, Elevator Level
Properties
Stacks Yes (5)
Recipe
Created With Electronics Printer, Fabricator
Cost 2g Copper, 4g Gold, 2g Steel, 2g Solder


Description

The elevator allows easy travel to other floors.

Use

Elevators allow easy access to other floors. They operate using two placement types: elevator level for floors where the elevator stops, and elevator shaft for those where they don't.
Logic and enumeration are automatically applied, and the elevator car is created when building a level.

All levels and shafts must face the same direction, so that their spines align..


Elevator Shaft

Elevator Shaft
Elevator Shaft front.png
Operation
Power Usage 5W
Construction
Placed with Kit (Elevator)
Placed on Large Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Elevator)


The shaft section to build on floors it should not open like floor frames etc.
Currently does not require power.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
On Boolean Turns the device on, when set >= 1. Turns it off, when set to <1.
Elevatorlevel Integer Returns current level carriage is on

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the device is turned on and receives power. (0 for no, 1 for yes)
On Boolean Returns whether the device is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current amount of power, required by the device, in watts.
Elevatorspeed Integer Returns 1 going up, 0 standing still and -1 going down
Elevatorlevel Integer Returns current level carriage is on

Elevator Level

Elevator Level
Elevator Level front.png
Operation
Power Usage 5W
Construction
Placed with Kit (Elevator)
Placed on Large Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Elevator)

The elevator level provides an entrance/exit stop for the elevator car.
Requires power to open the door automatically and use the call button

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
Open Boolean Opens the device , when set >= 1. Closes it, when set to < 1.
Lock Boolean Locks the device , when set >= 1. Unlocks it, when set to <1.
On Boolean Turns the device on, when set >= 1. Turns it off, when set to <1.
Elevatorlevel Integer Write the level you want the carriage to go to.


Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power Boolean Returns whether the device is turned on and receives power. (0 for no, 1 for yes)
Open Boolean Returns whether the device is open. (0 for no, 1 for yes)
Error Boolean Returns whether the device is flashing an error. (0 for no, 1 for yes)
Lock Boolean Returns whether the device is locked. (0 for no, 1 for yes)
On Boolean Returns whether the device is turned on. (0 for no, 1 for yes)
RequiredPower Integer Returns the current amount of power, required by the Glass Door, in watts.
ElevatorSpeed Integer Returns 1 going up, 0 standing still and -1 going down
ElevatorLevel Integer Returns current level carriage is on