Difference between revisions of "Active Vent"
From Unofficial Stationeers Wiki
F1r3w4rr10r (talk | contribs) (Update to use the new Data Network templates) |
(Tested out the active vent data inputs, they don't seem to work.) |
||
Line 39: | Line 39: | ||
|} | |} | ||
− | {{Data | + | {{Data Inputs}} |
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
! Parameter Name !! Data Type !! Description | ! Parameter Name !! Data Type !! Description | ||
|- | |- | ||
− | | Open || Boolean || | + | | Open || Boolean || Does not function. |
|- | |- | ||
| Mode || Integer || Sets the Active Vent mode to the passed setting. (See [[#Mode_Values|Mode Values]]) | | Mode || Integer || Sets the Active Vent mode to the passed setting. (See [[#Mode_Values|Mode Values]]) | ||
|- | |- | ||
− | | PressureExternal || Float || | + | | PressureExternal || Float || Does not function. |
|- | |- | ||
− | | PressureInternal || Float || | + | | PressureInternal || Float || Does not function. |
|- | |- | ||
| Lock || Boolean || Locks the Active Vent, when set to 1. Unlocks it, when set to 0. | | Lock || Boolean || Locks the Active Vent, when set to 1. Unlocks it, when set to 0. | ||
|- | |- | ||
− | | Setting || Float || | + | | Setting || Float || Does not function. |
|- | |- | ||
| On || Boolean || Turns the Active Vent on, when set to 1. Turns it off, when set to 0. | | On || Boolean || Turns the Active Vent on, when set to 1. Turns it off, when set to 0. |
Revision as of 19:00, 21 July 2018
Properties | |
---|---|
Stacks | Yes (5) |
Recipe | |
Created With | Hydraulic Pipe Bender, Fabricator |
Cost | 5g Iron, 1g Gold, 5g Copper |
Operation | |
---|---|
Power Usage | 100W |
Construction | |
Placed with | Active Vent (Item) |
Placed on | Small Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Active Vent (Item) |
Description
Used to move gasses from pipes, by using its inward or outward switches. It needs to be powered to function.
Note: The insert slot currently takes any item and seems to have no effect.
Data Network Properties
These are all Data Network properties of this device.
Mode Values
These lists the values and meanings for the "Mode" property of the Active Vent.
Value | Meaning |
---|---|
0 | "Outward" mode (Pumping gas from the connected pipe network to the outside.) |
1 | "Inward" mode (Pumping gas from the outside to the connected pipe network.) |
2 | (Unknown) |
Parameter Name | Data Type | Description |
---|---|---|
Open | Boolean | Does not function. |
Mode | Integer | Sets the Active Vent mode to the passed setting. (See Mode Values) |
PressureExternal | Float | Does not function. |
PressureInternal | Float | Does not function. |
Lock | Boolean | Locks the Active Vent, when set to 1. Unlocks it, when set to 0. |
Setting | Float | Does not function. |
On | Boolean | Turns the Active Vent on, when set to 1. Turns it off, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Active Vent is receiving power and is turned on. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Active Vent is open. (0 for no, 1 for yes) (Untested) |
Mode | Integer | Returns the setting of the current mode of the Active Vent. (See Mode Values) |
Error | Boolean | Returns whether the Active Vent is currently flashing an error. (0 for no, 1 for yes) |
PressureExternal | Float | Returns the desired external pressure of the Active Vent. (Untested) |
PressureInternal | Float | Returns the desired internal pressure of the Active vent. (Untested) |
Lock | Boolean | Returns whether the Active Vent is locked. (0 for no, 1 for yes) |
Setting | Float | Returns a range from 0.0 to 100.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent. |
Maximum | Integer | Returns 100. (Assumption) Returns the maximum throughput percentage of the Active Vent. |
Ratio | Float | Returns a range from 0.0 to 1.0. (Assumption) Returns the percentage amount of pumping throughput of the Active Vent. |
On | Boolean | Returns whether the Active Vent is set to on. (0 for no, 1 for yes) |
RequiredPower | Integer | Returns the current amount of power needed for the Active Vent. |