Actions

Difference between revisions of "Circuitboard (Air Control)"

From Unofficial Stationeers Wiki

(updating info a bit more)
m (elaborated on some information)
Line 37: Line 37:
 
== Operation ==  <!--T:7-->
 
== Operation ==  <!--T:7-->
  
Pressure mode with automatically try to maintain pressure at 100kPa, toggling the active vent between inward and outward.
+
Pressure mode with automatically try to maintain pressure at 100kPa, toggling the active vent between inward and outward as needed and turning off when the target pressure is reached.
 
 
Draught mode fills the room to 100kpa but then keep air flowing both ways.
 
  
 +
Draught mode tries to maintain pressure at 100kpa but doesn't turn off when the target pressure is reached. The vent will internally toggle between inward and outward airflow to continiously circulate gas between the pipe and room.
 +
 
Offline disables the active vent.
 
Offline disables the active vent.
  

Revision as of 22:06, 16 February 2018


Circuitboard (Air Control)
File:Circuitboard Air control.jpg
Properties
Stacks ??
Recipe
Created With Electronics Printer, Fabricator
Cost 5g Copper, 5g Gold


Description

Circuitboard (Air Control) can be placed inside of a Console to form a Air Control Console. It is one of many Circuitboards that can be fitted to a Console.

Console (Air Control)
Construction
Placed with {{{placed_with_item}}}
Placed on {{{placed_on_grid}}}


Air Control

The Air Control circuitboard in a console can be used to control active vents and display information about the environment.

Setup

Setup mode can be entered by placing a Data Disk into the slot on the Console.

The setup mode has three options: Pressure, Draught, and Offline. For basic functionality, at least one Gas Sensor and Active Vent should be selected on the setup screen.

Console (Air Control) in setup mode
Construction
Placed with {{{placed_with_item}}}
Placed on {{{placed_on_grid}}}


Operation

Pressure mode with automatically try to maintain pressure at 100kPa, toggling the active vent between inward and outward as needed and turning off when the target pressure is reached.

Draught mode tries to maintain pressure at 100kpa but doesn't turn off when the target pressure is reached. The vent will internally toggle between inward and outward airflow to continiously circulate gas between the pipe and room.

Offline disables the active vent.

Manual Operation Disabled
Construction
Placed with {{{placed_with_item}}}
Placed on {{{placed_on_grid}}}