Actions

Difference between revisions of "Airlock (Structure)"

From Unofficial Stationeers Wiki

(Initial contents)
 
(update desc and params)
 
(13 intermediate revisions by 5 users not shown)
Line 1: Line 1:
#REDIRECT [[Airlock]]
 
 
[[Category:Atmospherics]]
 
[[Category:Atmospherics]]
 
<languages/>
 
<languages/>
 
<translate>
 
<translate>
 
{{Structurebox
 
{{Structurebox
| image           =  
+
| name = Airlock
| name            = Airlock
+
| image = [[File:StructureAirlock.png]]
| power_usage     = 25W
+
| prefab_hash = -2105052344
| placed_with_item = [[Kit (Airlock)]]
+
| prefab_name = StructureAirlock
| placed_on_grid  = Large Grid
+
| power_usage = 25W
| decon_with_tool1 = [[Hand Drill]]
+
| placed_on_grid = Small Grid
| item_rec1        = [[Kit (Airlock)]]
+
| decon_with_tool1 = [[Wrench]]
 +
| placed_with_item = [[Kit (Airlock)]]
 +
| item_rec1 = [[Kit (Airlock)]]
 +
| decon_with_tool2 = [[Hand Drill]]
 +
| const_with_tool1 = [[Welding Torch]]
 +
| const_with_item1 = 2 x [[Steel Sheets]]
 +
| item_rec2 = 2 x [[Steel Sheets]]
 +
| decon_with_tool3 = [[Angle Grinder]]
 +
| const_with_tool2 = [[Crowbar]]
 +
| const_with_item2 = 2 x [[Plastic Sheets]]
 +
| item_rec3 = 2 x [[Plastic Sheets]]
 
}}
 
}}
 +
 +
<!--T:1-->
 
==Description==
 
==Description==
An Airlock is a powered door suitable for use in constructing an [[Special:MyLanguage/Guide (Airlock)|airlock chamber]]. It can withstand a [[Special:MyLanguage/Pressure|pressure]] differential of 1MPA and consumes 25W of [[Special:MyLanguage/Energy|energy]] per [[Special:MyLanguage/Energy#Tick|tick]].
+
<blockquote><q>The standard airlock is a powered portal that forms the main component of an airlock chamber. As long as the airlock is not locked, it can be manually opened using a crowbar.</q><br>
 +
'''- Stationpedia'''</blockquote>
 +
[[Guide (Airlock)]] provides additional information regarding the function, construction, and operation of airlocks.
  
An Airlock has separate [[Special:MyLanguage/Power#Ports|power]] and [[Special:MyLanguage/Data#Ports|data]] ports, a keypad on both sides which when clicked will open or close the door as long as it has power. An Airlock also has indicator lights which will turn red if the door is locked and green if the door is unlocked. As long as the door is unlocked it can be manually operated using a [[Special:MyLanguage/Crowbar|crowbar]] regardless of its power state.
+
<!--T:2-->
 +
==Characteristics==
 +
* It can withstand a [[Pressure]] differential of 1MPA.
 +
* It consumes 25W of [[Power]] per [[Tick]].
 +
* It has a separate [[Power Port]] and [[Data Port]].
 +
* It has a keypad on both sides.
 +
* It has indicator lights.  
 +
* If unlocked, it can be manually operated using a [[Crowbar]] regardless of its power state.
 +
* If enslaved by a [[Circuitboard (Airlock)|regular]] or a [[Circuitboard (Advanced Airlock)|advanced]] airlock circuit, it cannot be operated manually.
  
The airlock can be automatically controlled using a [[Special:MyLanguage/Circuitboard (Airlock)|regular]] or a [[Special:MyLanguage/Circuitboard (Advanced Airlock Control)|advanced]] airlock circuit board inside a [[Special:MyLanguage/Kit (Consoles) Console|console]]. Doing so will prevent the Airlock from being opened or closed manually, which could be a problem when power is lost.
+
<!--T:3-->
 +
==User Interface==
 +
An Airlock provides the following user interface:
 +
{| class="wikitable"
 +
|-
 +
! Name || Type !! Function
 +
|-
 +
| Keypad || Keypad  || Opens or closes the door as long as it has power
 +
|-
 +
| Lock || Indicator || Turns red when locked and green when unlocked
 +
|-
 +
|}
  
 +
<!--T:4-->
 +
==Settings==
 +
An Airlock has no settings.
 +
 +
<!--T:5-->
 
==Construction==
 
==Construction==
An Airlock is constructed using 1 x [[Special:MyLanguage/Kit (Airlock)|Kit (Airlock)]].
+
An Airlock is constructed using 1 x [[Kit (Airlock)]], 2 x [[Steel Sheets]], and 2 x [[Plastic Sheets]].
  
 +
You must first place the [[Kit (Airlock)]] by right clicking and selecting the unobstructed area. After the kit is placed, you will use a welding torch with 2 [[Steel Sheets]] in your other hand to complete stage 2.  To finalize the airlock, you must use your crowbar with 2 [[Plastic Sheets]] in your other hand.
 +
<!--T:6-->
 
==Deconstruction==
 
==Deconstruction==
An Airlock can be deconstructed at anytime using a [[Special:MyLanguage/Hand Drill|Hand Drill]].
+
An Airlock can be deconstructed in 3 stages.  You will first use your angle grinder to take off the 2 x [[Plastic Sheets]].  You will then use your hand drill to remove the 2 x [[Steel Sheets]]. Finally to remove the airlock, you will use your wrench to receive the 1 x [[Kit (Airlock)]].
 +
 
 +
{{Data Network Header}}
 +
 
 +
{{Data Parameters|
 +
{{Data Parameters/row|Power|Boolean|w=0|Can be read to return if the Airlock is correctly powered or not, set via the power system, return 1 if powered and 0 if not|multiple=2|0|Unpowered|1|Powered}}
 +
{{Data Parameters/row|Open|Integer|1 if device is open, otherwise 0}}
 +
{{Data Parameters/row|Mode|Integer|The mode of the Airlock.|multiple=2|0|Operate|1|Logic}}
 +
{{Data Parameters/row|Lock|Boolean|Disable manual operation of the Airlock.|multiple=2|0|Unlocked|1|Locked}}
 +
{{Data Parameters/row|Setting|Integer|A variable setting that can be read or written.}}
 +
{{Data Parameters/row|On|Boolean|The current state of the Airlock.|multiple=2|0|Off|1|On}}
 +
{{Data Parameters/row|RequiredPower|Integer|w=0|Idle operating power quantity, does not necessarily include extra demand power}}
 +
{{Data Parameters/row|Idle|Integer|w=0|Returns 1 if the Airlock is currently idle, otherwise 0}}
 +
{{Data Parameters/row|PrefabHash|Integer|w=0|The hash of the structure}}
 +
{{Data Parameters/row|ReferenceId|Integer|w=0|Unique Reference Identifier for this object}}
 +
{{Data Parameters/row|NameHash|Integer|w=0|Provides the hash value for the name of the object as a 32 bit integer.}}
 +
}}
  
 +
<!--T:9-->
 
==See Also==
 
==See Also==
<ul>
+
* [[Guide (Airlock)]]
    <li>[[Special:MyLanguage/Guide (Airlock)|Guide (Airlock)]]</li>
+
 
    <li>[[Special:MyLanguage/Kit (Airlock)|Kit (Airlock)]]</li>
+
* [[Circuitboard (Advanced Airlock)]]
    <li>[[Special:MyLanguage/Circuitboard (Advanced Airlock Control)|Circuitboard (Advanced Airlock Control)]]</li>
+
* [[Circuitboard (Airlock)]]
    <li>[[Special:MyLanguage/Circuitboard (Airlock)|Circuitboard (Airlock)]]</li>
+
* [[Kit (Airlock)]]
</ul>
 
 
</translate>
 
</translate>

Latest revision as of 05:44, 20 May 2024


Airlock
StructureAirlock.png
Operation
Power Usage 25W
Prefab Hash -2105052344
Prefab Name StructureAirlock
Construction
Placed with Kit (Airlock)
Placed on Small Grid
Stage 1
Next Stage Construction
Constructed with tool Welding Torch
Constructed with item 2 x Steel Sheets
Deconstruction
Deconstructed with Wrench
Item received Kit (Airlock)
Stage 2
Next Stage Construction
Constructed with tool Crowbar
Constructed with item 2 x Plastic Sheets
Deconstruction
Deconstructed with Hand Drill
Item received 2 x Steel Sheets
Stage 3
Deconstruction
Deconstructed with Angle Grinder
Item received 2 x Plastic Sheets



Description[edit]

The standard airlock is a powered portal that forms the main component of an airlock chamber. As long as the airlock is not locked, it can be manually opened using a crowbar.
- Stationpedia

Guide (Airlock) provides additional information regarding the function, construction, and operation of airlocks.

Characteristics[edit]

  • It can withstand a Pressure differential of 1MPA.
  • It consumes 25W of Power per Tick.
  • It has a separate Power Port and Data Port.
  • It has a keypad on both sides.
  • It has indicator lights.
  • If unlocked, it can be manually operated using a Crowbar regardless of its power state.
  • If enslaved by a regular or a advanced airlock circuit, it cannot be operated manually.

User Interface[edit]

An Airlock provides the following user interface:

Name Type Function
Keypad Keypad Opens or closes the door as long as it has power
Lock Indicator Turns red when locked and green when unlocked

Settings[edit]

An Airlock has no settings.

Construction[edit]

An Airlock is constructed using 1 x Kit (Airlock), 2 x Steel Sheets, and 2 x Plastic Sheets.

You must first place the Kit (Airlock) by right clicking and selecting the unobstructed area. After the kit is placed, you will use a welding torch with 2 Steel Sheets in your other hand to complete stage 2. To finalize the airlock, you must use your crowbar with 2 Plastic Sheets in your other hand.

Deconstruction[edit]

An Airlock can be deconstructed in 3 stages. You will first use your angle grinder to take off the 2 x Plastic Sheets. You will then use your hand drill to remove the 2 x Steel Sheets. Finally to remove the airlock, you will use your wrench to receive the 1 x Kit (Airlock).

Data Network Properties[edit]

These are all Data Network properties of this device.

Data Parameters[edit]

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).

Click here to see/hide all the data network properties
Parameter Name Data Type Access Value Description
Power Boolean
Read
0 Unpowered Can be read to return if the Airlock is correctly powered or not, set via the power system, return 1 if powered and 0 if not
1 Powered
Open Integer
Read Write
1 if device is open, otherwise 0
Mode Integer
Read Write
0 Operate The mode of the Airlock.
1 Logic
Lock Boolean
Read Write
0 Unlocked Disable manual operation of the Airlock.
1 Locked
Setting Integer
Read Write
A variable setting that can be read or written.
On Boolean
Read Write
0 Off The current state of the Airlock.
1 On
RequiredPower Integer
Read
Idle operating power quantity, does not necessarily include extra demand power
Idle Integer
Read
Returns 1 if the Airlock is currently idle, otherwise 0
PrefabHash Integer
Read
The hash of the structure
ReferenceId Integer
Read
Unique Reference Identifier for this object
NameHash Integer
Read
Provides the hash value for the name of the object as a 32 bit integer.


See Also[edit]