Difference between revisions of "Pipe Digital Valve"
From Unofficial Stationeers Wiki
Socramazibi (talk | contribs) |
Kahsikmahn (talk | contribs) (Updated Wattage usage from 25 to 5 Watts) |
||
(5 intermediate revisions by 5 users not shown) | |||
Line 1: | Line 1: | ||
− | + | [[Category:Atmospherics]] | |
− | |||
− | |||
{{Itembox | {{Itembox | ||
| name = Pipe Digital Valve | | name = Pipe Digital Valve | ||
| image = [[File:ItemPipeDigitalValve.png]] | | image = [[File:ItemPipeDigitalValve.png]] | ||
| stacks = 1 | | stacks = 1 | ||
+ | | createdwith = [[Hydraulic Pipe Bender]], [[Fabricator]] | ||
+ | | cost = 2g [[Copper Ingot|Copper]], 5g [[Steel Ingot|Steel]], 3g [[Invar Ingot|Invar]] | ||
}} | }} | ||
+ | =Pipe Digital Valve= | ||
+ | ==Description== | ||
+ | A valve which can be operated by logic network. Switching its "On" variable to 1 causes the valve to be fully open, switching to 0 closes the valve to completely close. | ||
+ | Power usage: 0 Watts when off. 5 Watts when on. | ||
+ | {{Data Network Header}} | ||
+ | {{Data Parameters}} | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! Parameter Name !! Data Type !! Description | ||
+ | |- | ||
+ | | Lock || Boolean || Locks the Pipe Digital Valve, when set to 1. Unlocks it, when set to 0. | ||
+ | |- | ||
+ | | Setting || Float || Does not function. | ||
+ | |- | ||
+ | | On || Boolean || Turns the Pipe Digital Valve on, when set to 1. Turns it off, when set to 0. | ||
+ | |} | ||
− | + | {{Data Outputs}} | |
− | + | {| class="wikitable" | |
+ | |- | ||
+ | ! Output Name !! Data Type !! Description | ||
+ | |- | ||
+ | | Maximum || Integer || Returns 100. (Assumption) Returns the maximum throughput percentage of the Pipe Digital Valve. | ||
+ | |- | ||
+ | | Lock || Boolean || Returns whether the Pipe Digital Valve is locked. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | Error || Boolean || Returns whether the Pipe Digital Valve is currently flashing an error. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | Setting || Float || Returns a range from 0.0 to 100.0. Does not function. (Assumption) Returns the percentage of opening of the Pipe Digital Valve. | ||
+ | |- | ||
+ | | RequiredPower || Integer || Returns the current amount of power needed for the Pipe Digital Valve. | ||
+ | |- | ||
+ | | Ratio || Float || Returns a range from 0.0 to 1.0. Does not function. (Assumption) Returns the differential in pressure between the sides of the Pipe Digital Valve. | ||
+ | |- | ||
+ | | Prefab Hash || Integer || (Assumption) Returns (-1280984102) a unique type identifier for the Pipe Digital Valve. | ||
+ | |- | ||
+ | | Power || Boolean || Returns whether the Pipe Digital Valve is receiving power and is turned on. (0 for no, 1 for yes) | ||
+ | |- | ||
+ | | On || Boolean || Returns whether the Pipe Digital Valve is set to on. (0 for no, 1 for yes) | ||
+ | |} |
Latest revision as of 22:27, 3 June 2024
Properties | |
---|---|
Stacks | No |
Recipe | |
Created With | Hydraulic Pipe Bender, Fabricator |
Cost | 2g Copper, 5g Steel, 3g Invar |
Contents
Pipe Digital Valve[edit]
Description[edit]
A valve which can be operated by logic network. Switching its "On" variable to 1 causes the valve to be fully open, switching to 0 closes the valve to completely close. Power usage: 0 Watts when off. 5 Watts when on.
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Lock | Boolean | Locks the Pipe Digital Valve, when set to 1. Unlocks it, when set to 0. |
Setting | Float | Does not function. |
On | Boolean | Turns the Pipe Digital Valve on, when set to 1. Turns it off, when set to 0. |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Maximum | Integer | Returns 100. (Assumption) Returns the maximum throughput percentage of the Pipe Digital Valve. |
Lock | Boolean | Returns whether the Pipe Digital Valve is locked. (0 for no, 1 for yes) |
Error | Boolean | Returns whether the Pipe Digital Valve is currently flashing an error. (0 for no, 1 for yes) |
Setting | Float | Returns a range from 0.0 to 100.0. Does not function. (Assumption) Returns the percentage of opening of the Pipe Digital Valve. |
RequiredPower | Integer | Returns the current amount of power needed for the Pipe Digital Valve. |
Ratio | Float | Returns a range from 0.0 to 1.0. Does not function. (Assumption) Returns the differential in pressure between the sides of the Pipe Digital Valve. |
Prefab Hash | Integer | (Assumption) Returns (-1280984102) a unique type identifier for the Pipe Digital Valve. |
Power | Boolean | Returns whether the Pipe Digital Valve is receiving power and is turned on. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Pipe Digital Valve is set to on. (0 for no, 1 for yes) |