Actions

Difference between revisions of "Tank"

From Unofficial Stationeers Wiki

m (Added Combustion Boolean)
m
 
(One intermediate revision by the same user not shown)
Line 72: Line 72:
 
| PrefabHash || Integer || Returns Prefab Hash number.
 
| PrefabHash || Integer || Returns Prefab Hash number.
 
|-
 
|-
| Open || Boolean ||  
+
| Open || Boolean || Does nothing
 
|-
 
|-
| Combustion || Boolean ||
+
| Combustion || Boolean || Returns true if gasses inside are combusting.
 
|}
 
|}

Latest revision as of 08:01, 30 January 2024


Kit (Tank) (Small Tank)
ItemKitTank.png
Max Pressure 60,795kPa (60MPa)
Recipe
Created With Hydraulic Pipe Bender, Fabricator
Cost 5g copper + 20g steel
Small Tank
TankSmall.png
1 Kit to place volume 6000L
Construction
Placed with Kit (Tank)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Tank)
Large Tank
File:TankBig.png
5 Kits to place volume 50000L
Construction
Placed with Kit (Tank)
Placed on Small Grid
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Tank)

Description[edit]

Tanks are used to store large amounts gasses.

The Small Tank requires 1 kit and can store 6000L.

The Large Tank requires 5 kits and can store 50000L, and is currently the largest capacity container for gasses. Combined with its high bursting pressure (>300 atmospheres) it can store upwards of 72000 mols at room temperature (20 °C). Given that pipes will burst at pressures greater than 60,795KPa, this is also a limit for the tanks, as all gases will be lost if the pipe connected to a tank ruptures.

Data Network Properties[edit]

These are all Data Network properties of this device.

Data Outputs[edit]

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Maximum Float
Temperature Float Returns the temperature inside the tank.
Setting Boolean
RatioWater Float Returns the ratio of Water (H2O) inside the tank.
RatioVolatiles Float Returns the ratio of Volatiles (H2) inside the tank.
RatioPollutant Float Returns the ratio of Pollutant (X) inside the tank.
RatioOxygen Float Returns the ratio of Oxygen (O2) inside the tank.
RatioNitrousOxide Float Returns the ratio of Nitrous Oxide (NO2) inside the tank.
RatioNitrogen Float Returns the ratio of Nitrogen (N2) inside the tank.
RatioCarbonDioxide Float Returns the ratio of Carbon Dioxide (CO2) inside the tank.
Ratio Float
Quantity Float Returns the quantity inside the tank in Mols.
Pressure Float Returns the pressure inside the tank in kilo Pascals.
PrefabHash Integer Returns Prefab Hash number.
Open Boolean Does nothing
Combustion Boolean Returns true if gasses inside are combusting.