Difference between revisions of "Transformer"
From Unofficial Stationeers Wiki
Roastduckie (talk | contribs) (Added medium transformer data and placement info) |
(Added unknown values based on the data in the Stationpedia.) |
||
Line 40: | Line 40: | ||
! Header text !! Header text !! Header text | ! Header text !! Header text !! Header text | ||
|- | |- | ||
− | | On || Boolean || Turns the Transformer on | + | | On || Boolean || Turns the Transformer on when set to 1. Turns it off when set to 0. |
|- | |- | ||
− | | Lock || Boolean || Locks the Transformer | + | | Lock || Boolean || Locks the Transformer when set to 1. Unlocks it when set to 0 |
|- | |- | ||
| Setting || Integer || Sets the Transformer's power (in Watts) limit. | | Setting || Integer || Sets the Transformer's power (in Watts) limit. | ||
Line 55: | Line 55: | ||
| On|| Boolean|| Returns whether the Transformer is turned on. (0 for no, 1 for yes) | | On|| Boolean|| Returns whether the Transformer is turned on. (0 for no, 1 for yes) | ||
|- | |- | ||
− | | | + | | Maximum || Integer|| Maximum setting of this device. (How high the device can be set, see description for specific numbers.) |
|- | |- | ||
| Lock || Boolean|| Returns whether the Transformer is locked. (0 for no, 1 for yes) | | Lock || Boolean|| Returns whether the Transformer is locked. (0 for no, 1 for yes) | ||
|- | |- | ||
− | | Error || | + | | Error || Boolean|| 1 if device is in error state, otherwise 0. |
|- | |- | ||
− | | Setting || | + | | Setting || Integer || Returns the current power limit (in Watts) of the Transformer. |
|- | |- | ||
− | | RequiredPower || | + | | RequiredPower || Integer || Idle operating power quantity. (how much power, in watts, the device itself is using, rather than how much power it is passing through.) |
|- | |- | ||
| Ratio || Float || (Unknown) | | Ratio || Float || (Unknown) | ||
|- | |- | ||
− | | PrefabHash|| | + | | PrefabHash|| Integer || The hash of the device. (Can be found in the Stationpedia.) |
|- | |- | ||
− | | Power|| | + | | Power|| Boolean || Returns 1 if the device is powered and on, otherwise 0. |
|} | |} |
Revision as of 16:22, 19 December 2020
Properties | |
---|---|
Stacks | No |
Recipe | |
Created With | Electronics Printer, Fabricator |
Cost | 10x Iron, 1x Gold , 3x Copper |
Properties | |
---|---|
Stacks | No |
Recipe | |
Created With | Electronics Printer, Fabricator |
Cost | 10x Steel, 5x Electrum |
Description
The transformer is used to control the maximum amount of power that will flow on a cable, preventing the cables from overloading on high power draw. There are three variants of the transformer:
The Transformer (Small) requires 1x Kit (Transformer) to place and is limited to 5,000 W of output. It can be placed in any orientation on a supporting surface (floor, wall, or ceiling) and is available as Transformer Reversed (Small).
The Transformer (Medium) requires 3x Kit (Transformer) to place and is limited to 25,000 W of output. Similarly, it can be placed on any floor, wall, or ceiling and is available as a Transformer Reversed (Medium).
The Transformer (Large) requires 1x Kit Transformer (Large) to place and is limited to 50,000 W of output. It can only be placed in one orientation, ideally the floor, but it can be stacked above floor level by placing it partway into a frame.
Usage
Given that the transformer can limit power very specifically (with large 100 W increments or small 10 W increments), you can control or stop the output line from drawing more than the transformer gives out. This can be used to control many items that don't have a changing power usage, such as lights, volume pumps, pipe regulators, active vents, and more. This is similar to the Area Power Controller but does not have a battery buffer.
Notes
Data will not flow through a transformer, isolating the circuit behind their input.
Data Network Properties
These are all Data Network properties of this device. This list is not tested at all for the Transformer Small and not complete for Transformer (kit/large variant).
Data Parameters
These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
Header text | Header text | Header text |
---|---|---|
On | Boolean | Turns the Transformer on when set to 1. Turns it off when set to 0. |
Lock | Boolean | Locks the Transformer when set to 1. Unlocks it when set to 0 |
Setting | Integer | Sets the Transformer's power (in Watts) limit. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them. You cannot read ratios in IC2 chip (so far)
Parameter Name | Data Type | Description |
---|---|---|
On | Boolean | Returns whether the Transformer is turned on. (0 for no, 1 for yes) |
Maximum | Integer | Maximum setting of this device. (How high the device can be set, see description for specific numbers.) |
Lock | Boolean | Returns whether the Transformer is locked. (0 for no, 1 for yes) |
Error | Boolean | 1 if device is in error state, otherwise 0. |
Setting | Integer | Returns the current power limit (in Watts) of the Transformer. |
RequiredPower | Integer | Idle operating power quantity. (how much power, in watts, the device itself is using, rather than how much power it is passing through.) |
Ratio | Float | (Unknown) |
PrefabHash | Integer | The hash of the device. (Can be found in the Stationpedia.) |
Power | Boolean | Returns 1 if the device is powered and on, otherwise 0. |