Actions

Difference between revisions of "Transformer"

From Unofficial Stationeers Wiki

m (Correction: both of these items may also be constructed at the Electronics Printer.)
Line 24: Line 24:
  
 
==Notes==
 
==Notes==
Data will not flow through a transformer, isolating the circuit behind their input.
+
Data will not flow through a transformer, isolating the circuit behind their input.  
 +
 
 +
 
 +
===Data Network Properties===
 +
These are all Data Network properties of this device. This list is not tested at all for the Transformer Small and not complete for Transformer (kit/large variant).
 +
 
 +
==Data Parameters==
 +
These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
 +
{| class="wikitable"
 +
|-
 +
! Header text !! Header text !! Header text
 +
|-
 +
| On || Boolean || Turns the Transformer on, when set to 1. Turns it off, when set to 0.
 +
|-
 +
| Lock || Boolean || Locks the Transformer, when set to 1. Unlocks it when set to 0
 +
|-
 +
| Setting || Integer || Sets the Transformer's power (in Watts) limit.
 +
|}
 +
 
 +
==Data Outputs==
 +
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them. You cannot read ratios in IC2 chip (so far)
 +
{| class="wikitable"
 +
|-
 +
! Parameter Name !! Data Type !! Description
 +
|-
 +
| On|| Boolean|| Returns whether the Transformer is turned on. (0 for no, 1 for yes) 
 +
|-
 +
| Max || Integer|| (Unknown)
 +
|-
 +
| Lock || Boolean|| Returns whether the Transformer is locked. (0 for no, 1 for yes)
 +
|-
 +
| Error || Integer|| (Unknown)
 +
|-
 +
| Setting || Intiger || Returns the current power limit (in Watts) of the Transformer
 +
|-
 +
| RequiredPower || (Unknown) || (Unknown)
 +
|-
 +
| Ratio || Float || (Unknown)
 +
|-
 +
| PrefabHash|| (Unknown) || (Unknown)
 +
|-
 +
| Power|| (Unknown) || (Unknown)
 +
|}

Revision as of 15:52, 18 June 2020

Kit Transformer Small
ItemKitTransformerSmall.png
Properties
Stacks No
Recipe
Created With Electronics Printer, Fabricator
Cost 10x Iron, 1x Gold , 3x Copper


Kit Transformer
ItemKitTransformer.png
Properties
Stacks No
Recipe
Created With Electronics Printer, Fabricator
Cost 10x Steel, 5x Electrum


Description

The transformer is used to control the maximum amount of power that will flow on a cable, preventing the cables from overloading on high power draw. It comes in 2 variants, Transformer Small and Transformer.

The small transformer is limited to 5,000W output and the large one to 50,000W.

Usage

Given that the transformer can limit power very specifically (with 100W increments), you can control or stop the output line from drawing more than the transformer gives out. This can be used to control many items that don't have a changing power usage, such as lights, volume pumps, pipe regulators, active vents, and more. This is similar to the Area Power Controller but does not have a battery buffer.

Notes

Data will not flow through a transformer, isolating the circuit behind their input.


Data Network Properties

These are all Data Network properties of this device. This list is not tested at all for the Transformer Small and not complete for Transformer (kit/large variant).

Data Parameters

These are all parameters, that can be written to with a Logic Writer, Batch Writer, or Integrated Circuit (IC10). The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.

Header text Header text Header text
On Boolean Turns the Transformer on, when set to 1. Turns it off, when set to 0.
Lock Boolean Locks the Transformer, when set to 1. Unlocks it when set to 0
Setting Integer Sets the Transformer's power (in Watts) limit.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them. You cannot read ratios in IC2 chip (so far)

Parameter Name Data Type Description
On Boolean Returns whether the Transformer is turned on. (0 for no, 1 for yes)
Max Integer (Unknown)
Lock Boolean Returns whether the Transformer is locked. (0 for no, 1 for yes)
Error Integer (Unknown)
Setting Intiger Returns the current power limit (in Watts) of the Transformer
RequiredPower (Unknown) (Unknown)
Ratio Float (Unknown)
PrefabHash (Unknown) (Unknown)
Power (Unknown) (Unknown)