Difference between revisions of "Composite Door"
From Unofficial Stationeers Wiki
m (Better explanation) |
m (Correction) |
||
Line 102: | Line 102: | ||
| Lock || Boolean || Returns whether the lock on the door is active. | | Lock || Boolean || Returns whether the lock on the door is active. | ||
|- | |- | ||
− | | Setting || Boolean || Returns desired state of the door. (0 for close, 1 for open) | + | | Setting || Boolean || Returns desired state of the door. (0 for close, 1 for open) When Mode = 1 |
|- | |- | ||
| Mode || Integer || 0 = Manual Control, 1 = Logic Control. | | Mode || Integer || 0 = Manual Control, 1 = Logic Control. |
Revision as of 19:39, 29 August 2021
Recipe | |
---|---|
Created With | Autolathe, Fabricator |
Cost | 7g Iron, 3g Copper |
Operation | |
---|---|
Power Usage | 10W |
Construction | |
Placed with | Kit (Door) |
Placed on | Large Grid |
Stage 1 | |
Deconstruction | |
Deconstructed with | Crowbar |
Contents
Purpose
A Composite Door is one type of door created using the Kit_(Door).
Characteristics
- The Door allows separation between two different rooms.
- It consumes 10W of Power per Tick.
- It has a separate Power Port and Data Port.
Tips
- A Crowbar can be used to force the door open, as long as it is not Locked.
User Interface
An <ITEM> has no user interface. An <ITEM> provides the following user interface:
Name | Type | Function |
---|---|---|
<Name> | <Type> | <Function> |
Settings
An <ITEM> has no settings. An <ITEM> will have the following settings:
Name | Description |
---|---|
<Name> | <Description> |
Construction
- 1x Plastic_Sheets using a Welding_Torch.
- 1x Glass_Sheets using a Crowbar.
Deconstruction
The following tools must be used in order to deconstruct the Door:
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
On | Boolean | Turns the Door on when set to 1. Turns it off when set to 0. |
Open | Boolean | Opens the Door when set to 1. Closes it when set to 0. |
Lock | Boolean | Locks the Door when set to 1. Unlocks it when set to 0. |
Setting | Boolean | No Function. |
Mode | Integer | 0 = Manual Control, 1 = Logic Control. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | Boolean | Returns whether the Door is turned on and receives power. (0 for no, 1 for yes) |
On | Boolean | Returns whether the Door is turned on. (0 for no, 1 for yes) |
Open | Boolean | Returns whether the Door is currently open. |
Lock | Boolean | Returns whether the lock on the door is active. |
Setting | Boolean | Returns desired state of the door. (0 for close, 1 for open) When Mode = 1 |
Mode | Integer | 0 = Manual Control, 1 = Logic Control. |
RequiredPower | Integer | Returns the current amount of power required by the Door, in watts. |
See Also
- [[Guide (<Subject>)]]
- [[<Related Kits or Items>)]]