Actions

Sensors

From Unofficial Stationeers Wiki

Revision as of 00:05, 6 September 2024 by Inky19 (talk | contribs) (Removal of a seemingly obsolete warning (I tested it in a world but found no difference, perhaps it has since been corrected).)
Other languages:
English
Kit (Sensors)
ItemKitSensor.png
Constructing Options Daylight, Motion or Gas Sensor
Properties
Stacks Yes (5)
Recipe
Created With Electronics Printer, Hydraulic Pipe Bender
Cost 3g Iron, 1g Gold, 1g Copper
Hydraulic Pipe Bender has an altered recipe 1g iron instead of 3g


Daylight Sensor
StructureDaylightSensor.png
Prefab Hash 1076425094
Prefab Name StructureDaylightSensor
Construction
Placed with Kit (Sensors)
Placed on Small Grid, On Frames
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Sensors)



Motion Sensor
ItemMotionSensor.png
Prefab Hash -1713470563
Prefab Name StructureMotionSensor
Construction
Placed with Kit (Sensors)
Placed on Small Grid, On Frames
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Sensors)



Gas Sensor
ItemGasSensor.png
Prefab Hash -1252983604
Prefab Name StructureGasSensor
Construction
Placed with Kit (Sensors)
Placed on Small Grid, On Frames
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Sensors)



Occupancy Sensor
StructureOccupancySensor.png
Prefab Hash 322782515
Prefab Name StructureOccupancySensor
Construction
Placed with Kit (Sensors)
Placed on Small Grid, On Frames
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Sensors)



Proximity Sensor
StructureProximitySensor.png
Prefab Hash 568800213
Prefab Name StructureProximitySensor
Construction
Placed with Kit (Sensors)
Placed on Small Grid, On Frames
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Kit (Sensors)



Description

Sensors are used to detect different parameters of their surroundings.
Only the Daylight Sensor can be accessed directly by pointing it. Other sensors require a tablet with a Configuration Cartridge to be accessed manually.
Their outputs can also be accessed using an Logic Reader or an Integrated Circuit inserted in an IC Housing.


Daylight Sensor

The daylight sensor reports whether the sun hits the large grid the sensor is in, as well as the solar angle. Looking at the sensor will provide a tool-tip readout of this information, even when not connected to the network. The orientation of the daylight sensor is important, it will read different angle values depending on the orientation.

Modes

Warning Warning: While the Mode and SolarAngle properties described below are still available, they are being deprecated in favor of Horizontal and Vertical data properties, returning the same as their Mode counterparts.

The daylight sensor has a Mode property which can be set with Logic Writer and Memory chip, or with an Integrated Circuit:

Value Name Description
0 Default The sensor will return the absolute value of the angle formed by the source of light and the normal vector of the sensor (towards which the grey/green part is facing). 0 means the source of light is facing to the sensor, 90 means it is aligned with the surface the sensor was laid on, and 180 means the source of light is in the back of the sensor. The angle is always a positive value between 0 and 180.
1 Horizontal Returns the angle from the position of the source of light parallel to the surface of the sensor. The angle can be negative, ranging between -180 and +180.
2 Vertical The sensor measures the angle from the position of the light source perpendicular to the surface of the sensor.
daylight sensor in horizontal mode
daylight sensor in vertical mode

Notes

Solar panel work using clockwise reference angles, which means depending of the situation you may have to invert the values returned by sensors' horizontal or vertical modes.

The sensor always reports an angle to a logic reader at all times.

See https://stationeers-wiki.com/Solar_Logic_Circuits_Guide for more solar panel logic discussion.

Examples

On the moon/space :

  • If the daylight sensor is fixed on the floor, it will report 90 degrees at sunrise, up to 0 degrees at noon, back to 90 degrees at sunset, to 180 degrees at midnight, and back to 90 at sunrise.
  • If fixed on a ceiling the cycle will be opposite, i.e.: 90 -> 180 -> 90 -> 0 -> 90.
  • If fixed to an east facing wall, the cycle from sunrise is: 0 -> 90 -> 180 -> 90 -> 0.
  • If fixed to a west facing wall, the cycle is opposite, i.e.: 180 -> 90 -> 0 -> 90 -> 180.
  • If fixed to a north or south facing wall it will stay at 90 degrees all the time.

Other :

  • If you lay a sensor on the ground, facing upwards, connector towards south,configured in horizontal mode, it will work like a compass with 0 = north, 90 = east, 180 = south and -90 = west

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).

Click here to see/hide all the data network properties
Parameter Name Data Type Access Value Description
Mode Integer
Read Write
0 Default SolarAngle mode
1 Horizontal
2 Vertical
Activate Boolean
Read Write
1 if the device is running, 0 otherwise
Horizontal Float
Read Write
Same as SolarAngle reported for Horizontal mode
Vertical Float
Read Write
Same as SolarAngle reported for Vertical mode
SolarAngle Float
Read
See Modes above. Probably soon deprecated in favor of Horizontal and Vertical
On Boolean
Read
0 if Off, 1 if On
PrefabHash Integer
Read
The hash of the structure
SolarIrradiance Float
Read
The current solar irradiance (in W/m²)
ReferenceId Integer
Read
Unique Reference Identifier for this object
NameHash Integer
Read
Provides the hash value for the name of the object as a 32 bit integer.


Motion Sensor

The motion sensor activates when a player or object enters the large grid square where the sensor is, and it will deactivate when no more players or objects are in the area.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description


Gas Sensor

The gas sensor will report information about the gas in the current atmosphere, such as pressure, contents and temperature.

Note: Temperature is given in Kelvin, while your suit gives a readout in Celsius.

Celsius + 273.15 = Kelvin

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

The gas sensor has no Input parameters, it's a read only device.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Pressure Float In kPa
Temperature Float In Kelvin
RatioOxygen Float The ratio of oxygen in the atmosphere. A value between 0 (no oxygen at all, or 0%) and 1 ( pure oxygen atmosphere, or 100%)
RatioCarbonDioxide Float
RatioNitrogen Float
RatioNitrousOxide Float
RatioPollutant Float
RatioVolatiles Float
RatioWater Float
Combustion


Occupancy Sensor

The occupancy sensor will detect the presence of a player when placed within a defined room. A defined room is when the game detects the space is entirely closed off from the rest of the world with walls, doors, etc. These do not need to be in the finished state to count as sealing a room.

Note: You can determine if a room is define by using the atmos analyzer chip with the tablet. If the top says "Room #" the room is sufficiently closed in.

Data Network Properties

These are all Data Network properties of this device.

Data Parameters

The gas sensor has no Input parameters, it's a read only device.

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Activate Bool Whether a player is detected in the room. 0 means no one present, 1 means at least one player present
Quantity Float Unknown
PrefabHash Float Returns the Hash of the Occupancy Sensor (322782515)