Kit (Airlock Gate)
From Unofficial Stationeers Wiki
(Redirected from Airlock Gate)
![]() | |
| Properties | |
|---|---|
| Stacks | Yes (5) |
| Recipe | |
| Created With | Hydraulic Pipe Bender |
| Cost | 5g Gold, 5g Copper, 25g Steel |
![]() | |
| Operation | |
|---|---|
| Power Usage | 25W |
| Prefab Hash | 1736080881 |
| Construction | |
| Placed with | Kit (Airlock Gate) |
| Placed on | Large Grid Edge 2x1 |
| Stage 1 | |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | Kit (Airlock Gate) |
![]() | |
| Operation | |
|---|---|
| Power Usage | 25W |
| Prefab Hash | -566348148 |
| Construction | |
| Placed with | 2x Kit (Airlock Gate) |
| Placed on | Large Grid Edge 3x1 |
| Stage 1 | |
| Next Stage Construction | |
| Constructed with tool | Welding Torch |
| Constructed with item | 2x Steel Sheet |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | 2x Kit (Airlock Gate) |
| Stage 2 | |
| Deconstruction | |
| Deconstructed with | Wrench |
| Item received | 2x Steel Sheet |
![]() | |
| Operation | |
|---|---|
| Power Usage | 25W |
| Prefab Hash | -1351081801 |
| Construction | |
| Placed with | 3x Kit (Airlock Gate) |
| Placed on | Large Grid Edge 4x1 |
| Stage 1 | |
| Next Stage Construction | |
| Constructed with tool | Welding Torch |
| Constructed with item | 3x Steel Sheet |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | 3x Kit (Airlock Gate) |
| Stage 2 | |
| Deconstruction | |
| Deconstructed with | Wrench |
| Item received | 3x Steel Sheet |
Description[edit]
The Hangar Door is a door that opens and closes by retracting or extending a sectioned door either vertically or horizontally along a large grid edge. This behaviour is perfect for building garage doors or large entrances.
This is an example of usage:
The gate has one power input and one data input. Like the Airlock, it has no integrated buttons to open and close the door and must be controlled via a logic signal, or forced open with a Crowbar.
All gates occupy at minimum one grid cell, halfway, for their base. Small, Medium, and Large hangar doors extend a further 1, 2, and 3 large grid cells when closed.
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
| Parameter Name | Data Type | Description |
|---|---|---|
| Lock | Boolean | Unknown. |
| Mode | Boolean | Unknown. |
| On | Boolean | Turns the Airlock Gate on or off. |
| Open | Boolean | Close or open the Airlock Gate. |
| Setting | Boolean | Unknown as input. |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
| Output Name | Data Type | Description |
|---|---|---|
| Lock | Boolean | Unknown. |
| Mode | Boolean | Unknown. |
| On | Boolean | If the Airlock Gate is on or off. |
| Open | Boolean | If the Airlock Gate is open or close. |
| PrefabHash | Integer | 0 or 1736080881 |
| Setting | Boolean | Wrapper/Mirror of Open value. |