Difference between revisions of "Kit (Heat Exchanger)"
From Unofficial Stationeers Wiki
EterniaLogic (talk | contribs) (Created page with "<languages/> <translate> Category:Machines {{Itembox | stacks = 5 | name = Kit (Heat Exchanger) | createdwith = Hydraulic Pipe Bender, Fabricator |...") |
|||
(One intermediate revision by one other user not shown) | |||
Line 5: | Line 5: | ||
| stacks = 5 | | stacks = 5 | ||
| name = Kit (Heat Exchanger) | | name = Kit (Heat Exchanger) | ||
− | | createdwith = [[Hydraulic Pipe Bender | + | | createdwith = [[Hydraulic Pipe Bender]] |
− | | cost = | + | | cost = 5g [[Copper]] 5g [[Steel]] |
| logic = | | logic = | ||
}} | }} | ||
Line 12: | Line 12: | ||
| name = Heat Exchanger - Gas | | name = Heat Exchanger - Gas | ||
| image = [[File:{{#setmainimage:HeatExchangerGas.png}}]] | | image = [[File:{{#setmainimage:HeatExchangerGas.png}}]] | ||
− | | power_usage = | + | | power_usage = 0 |
| placed_with_item = [[Kit (Heat Exchanger)]] | | placed_with_item = [[Kit (Heat Exchanger)]] | ||
| placed_on_grid = Small Grid, On Frames | | placed_on_grid = Small Grid, On Frames |
Latest revision as of 09:14, 3 August 2022
Properties | |
---|---|
Stacks | Yes (5) |
Recipe | |
Created With | Hydraulic Pipe Bender |
Cost | 5g Copper 5g Steel |
File:HeatExchangerGas.png | |
Operation | |
---|---|
Power Usage | 0 |
Construction | |
Placed with | Kit (Heat Exchanger) |
Placed on | Small Grid, On Frames |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Heat Exchanger) |
File:HeatExchangerLiquid.png | |
Operation | |
---|---|
Power Usage | 10W idle + 1000W active |
Construction | |
Placed with | Kit (Heat Exchanger) |
Placed on | Small Grid, On Frames |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Heat Exchanger) |
File:HeatExchangerLiquidGas.png | |
Operation | |
---|---|
Power Usage | 10W idle + 1000W active |
Construction | |
Placed with | Kit (Heat Exchanger) |
Placed on | Small Grid, On Frames |
Stage 1 | |
Deconstruction | |
Deconstructed with | Hand Drill |
Item received | Kit (Heat Exchanger) |
Description[edit]
Exchanges heat between two pipe networks.
Usage[edit]
There are three variants of the heat exchanger, there are two inputs and two outputs labeled on the device itself.
Data Network Properties[edit]
These are all Data Network properties of this device.
Data Parameters[edit]
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
Parameter Name | Data Type | Description |
---|---|---|
Lock | ||
Setting | Boolean | Unused |
On |
Data Outputs[edit]
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
Output Name | Data Type | Description |
---|---|---|
Power | ||
Error | ||
Lock | ||
Setting | ||
Maximum | ||
Ratio | ||
On | ||
Required Power |